scholarly journals Pengujian Kinerja Pompa Sentrifugal Multistage Berkapasitas 118,5 KW pada PLTP Berdasarakan Standar ISO 9906

2021 ◽  
Vol 5 (2) ◽  
pp. 101-113
Author(s):  
Wahyu Hidayat ◽  
Damawidjaya Biksono ◽  
Dadan Zulpian

AbstrakPengujian unjuk kerja pompa sentrifugal multistage berkapasitas 118,5 kW di kawasan Pembangkit Listrik Tenaga Panas Bumi (PLTP) daerah Jawa Barat saat ini akan menyesuaikan prosedur standar. Standar pengujian pompa diterapkan pada proses pengujian pompa dengan tujuan nilai hasil pengujian valid. Nilai head dan debit yang didapat dari pengujian dibandingkan dengan hasil pengujian sebelum penerapan standar. Pengujian pompa sentrifugal menerapkan metode pengujian lapangan dengan menerapkan standar ISO 9906-2012. Standar ISO 9906-2012 adalah panduan baku pengujian pompa rotodinamik. Dari hasil pengujian, didapatkan kurva pompa sentrifugal multistage debit maksimal 116,64 m3/h pada head 275,13 m. Pada data spesifikasi kapasitas pompa sebesar 108 m3/jam dan head total sebesar 300 m. Hal ini berarti prosedur pengujian pompa ISO 9906-2012 dapat memungkinkan kita untuk melihat kinerja pompa aktual.Kata kunci: pompa sentrifugal, pengujian lapangan, uji kinerja pompa, ISO 9906  AbstractPerformance test of multistage centrifugal pump at geothermal power plant area around west java is about to adapt standard procedure. Pump testing standards are applied during pump performance test in order to valid test result values. Head and flowrate value from current test compared with previous test result before standard are applied. Pump performance test use field test method by applying ISO 9906-2012 standard. ISO 9906-2012 standard is a normative guidance for rotodynamic pump testing. The test result shows multistage centrifugal pump curve maximum flowrate is 116,64 m3/h at total head 275,13 m. Pump specification sheet shows that maximum capacity is 108 m3/h and total head 300 m. It indicates that ISO 9906-2012 standard pump testing procedure allow us to determine actual pump performance.Kata kunci: Centrifugal pump, field test, performance test, ISO 9906

2011 ◽  
Vol 121-126 ◽  
pp. 3195-3199
Author(s):  
Li Feng Yang ◽  
Jun Yuan ◽  
Wei Na Liu ◽  
Xiu Ming Nie ◽  
Xue Liang Pei

Use Kingview to acquire and display the centrifugal pump performance parameters for the real-time data, and will stored the collected experimental data in Access databases, using VB database read, and drawing function for the data processing and rendering performance parameters of relationship curves.


2021 ◽  
Vol 6 (1) ◽  
pp. 33-40
Author(s):  
Edi Widodo ◽  
Rizky Dwi Jayanto

This study discusses the planning in making a centrifugal pump installation with a combination of two series, namely series and parallel. The concept of discussion refers more to the upgrading of the installation system and calculates the estimated processing time needed to test the performance of the results of the installation that has been made. From the results of the research, it was found that for the preparation of series series installation it takes ± 8.5 minutes including the cutting process of materials and component installation, while the time required in making the installation of parallel circuits ± 28 minutes so that the total manufacturing of the two types of series takes 36, 5 minutes. In terms of performance generated from each installation obtained at full aperture where for the series of head series the value obtained is 37.6 m with a flow capacity of 3.25 l / s while for the head value on the parallel pump obtained by 27.7 m with a capacity flow of 3.75 l / s and this pump operates at 2900 rpm. So it can be seen from the results of the head and flow capacity obtained values ​​indicate good pump performance and ready to be used as a practical tool in the laboratory.


2015 ◽  
Vol 105 ◽  
pp. 270-275 ◽  
Author(s):  
Rakibuzzaman ◽  
Sang-Ho Suh ◽  
Kim Kyung-Wuk ◽  
Hyung-Ho Kim ◽  
Min Tae Cho ◽  
...  

2018 ◽  
Vol 20 (2) ◽  
pp. 29-35
Author(s):  
Adam Hafizar Pohan

This study was conducted to identify the performance of centrifugal pump series configuration and parallel configuration experimentally and Ansys simulation. In the previous study, the performance of centrifugal pumps was calculated by varying the valve opening. In this study researchers varied motor rotation of 1000 rpm, 1200 rpm, 1400 rpm, 1600 rpm and 1800 rpm with open valve 100%. The results show that series configuration has higher head value than parallel configuration. While the parallel configuration has a higher capacity value than the series configuration. The highest pump efficiency for this pump performance test is in series configuration of 1800 rpm is 83.4% for experimental and 85% for simulation. While the lowest pump efficiency is in parallel configuration pumps of 1800 rpm with an efficiency 14.1% for experimental and 15.5% for simulation.


2017 ◽  
Vol 2 (1) ◽  
pp. 51
Author(s):  
Wagimin Wagimin

Abstract Penelitian ini bertujuan untuk mengembangkan perangkat materi pembelajaran untuk pengajaran sosiologi guna memotivasi siswa. Penelitian ini menggunakan metode penelitian dan pengembangan guna menformulasi produk dan mengukur efektifitasnya melalui validasi dan pengujian ahli di bidangnya. Ada tiga tipe test yang digunakan yaitu, one to one, small group, dan field test yang menunjukkan bahwa desain materi tersebut efektif. Setelah melalui revisi, desain meteri pembelajaran Sosiologi dianggap bermanfaat dan dapat digunakan dalam proses belajar mengajar Kata Kunci: Perangkat pembelajaran, mata pelajaran Sosiologi, siswa Madrasah Aliyah Abstract [Tittle: The Development of Sosiology Instructional Material for The Students fo Islamic Senior High School] . The research aims at developing a set of instructional material for teaching Sociology in order to motivate the students. The researcher employed a research and developing method to formulate a product and to measure its effectiveness through validation and trial-out by the experts of content-material and material-design. There were three types of trial to test the design; one to one, small group, and field test. Based on the test result, it was found that students in average can achieve 84% of overall score which indicate that the designed material is effective. After being revised several times in each stage, the design of instructional material for Sociology subject is considered as beneficial and able to be used in the teaching learning process


Sign in / Sign up

Export Citation Format

Share Document