scholarly journals Behavior of Double Fish Plate Connector between Steel Plate Shear Wall Structure and Steel Frame

Author(s):  
Guochang Li ◽  
Zengmei Qiu ◽  
Zhijian Yang

This paper mainly researched the behavior of double fish plate connector between steel plate shear wall structure and steel frame. Four single fish plate connectors and four double fish plate connectors were tested under monotonic and cyclic loading. The hysteretic curves, skeleton curves, stiffness degradation curve and ductility coefficient were considered to study the behavior of two connections. Results showed that the behavior of double fish plate connector between steel plate shear walls and steel frame was better than single fish plate connector. Double fish plate connectors had higher bearing capacity, slower stiffness degradation, better ductility and better energy dissipation capacity. Constraint effect of steel plate shear walls became stronger, and the out-of-plane buckling failure of steel plate shear walls was delayed. Therefore, the double fish plate connectors could improve the behavior of connection between steel plate shear walls and steel frame, and provide a reference for engineering application

2021 ◽  
pp. 136943322110542
Author(s):  
Mahdi Usefvand ◽  
Ahmad Maleki ◽  
Babak Alinejad

Coupled steel plate shear wall (C-SPSW) is one of the resisting systems with high ductility and energy absorption capacity. Energy dissipation in the C-SPSW system is accomplished by the bending and shear behavior of the link beams and SPSW. Energy dissipation and floor displacement control occur through link beams at low seismic levels, easily replaced after an earthquake. In this study, an innovative coupled steel plate shear wall with a yielding FUSE is presented. The system uses a high-ductility FUSE pin element instead of a link beam, which has good replaceability after the earthquake. In this study, four models of coupled steel plate shear walls were investigated with I-shaped link beam, I-shaped link beam with reduced beam section (RBS), box-link beam with RBS, and FUSE pin element under cyclic loading. The finite element method was used through ABAQUS software to develop the C-SPSW models. Two test specimens of coupled steel plate shear walls were validated to verify the finite element method results. Comparative results of the hysteresis curves obtained from the finite element analysis with the experimental curves indicated that the finite element model offered a good prediction of the hysteresis behavior of C-SPSW. It is demonstrated in this study that the FUSE pin can improve and increase the strength and energy dissipation of a C-SPSW system by 19% and 20%, respectively.


2012 ◽  
Vol 06 (01) ◽  
pp. 1250004 ◽  
Author(s):  
SWAPNIL B. KHARMALE ◽  
SIDDHARTHA GHOSH

The thin unstiffened steel plate shear wall (SPSW) system has now emerged as a promising lateral load resisting system. Considering performance-based design requirements, a ductility-based design was recently proposed for SPSW systems. It was felt that a detailed and closer look into the aspect of seismic lateral force distribution was necessary in this method. An investigation toward finding a suitable lateral force distribution for ductility-based design of SPSW is presented in this paper. The investigation is based on trial designs for a variety of scenarios where five common lateral force distributions are considered. The effectiveness of an assumed trial distribution is measured primarily on the basis of how closely the design achieves the target ductility ratio, which is measured in terms of the roof displacement. All trial distributions are found to be almost equally effective. Therefore, the use of any commonly adopted lateral force distribution is recommended for plastic design of SPSW systems.


Author(s):  
Ali Kaveh ◽  
Mohamad Farhadmanesh

In this paper three well-known metaheuristic algorithms comprising of Colliding Bodies Optimization, Enhanced Colliding Bodies Optimization, and Particle Swarm Optimization are employed for size and performance optimization of steel plate shear wall systems. Low seismic and high seismic optimal designs of these systems are performed according to the provisions of AISC 360 and AISC 341. In one part of the low seismic example, a moment frame and Steel Plate Shear Wall (SPW) strength are compared. Performance optimization of the Special Plate Shear Wall (SPSW) for size optimized system is one of the objectives of the high seismic example. Finally, base shear sensitivity analysis on optimal high seismic design of SPSW and size optimization of a 6-story to a 12-story SPSW are performed to have a comprehensive view on the optimal design of steel plate shear walls.


2015 ◽  
Vol 1120-1121 ◽  
pp. 1516-1519
Author(s):  
Yong Song Shao ◽  
Feng Ru Shao

Due to mechanical performances of brace and steel plate, mechanical properties of semi-rigid joints and its construction and installation, semi-rigid steel frame-braced steel plate shear wall system is proposed. Nonlinear static analysis with parameters (thickness of plate, type of brace, size of brace and the ratio of span to height) changed of a single-span and single-floor semi-rigid steel frame-braced steel plate shear wall system illustrates that braced steel plate shear walls contributes obviously to bearing capacity and lateral rigidity of semi-rigid steel frame. Also, the finite element analysis (by ANSYS) show that semi-rigid steel frame-braced steel plate shear wall system has excellent ductility.


2013 ◽  
Vol 351-352 ◽  
pp. 219-222
Author(s):  
Xiao Tong Peng ◽  
Ying Ying Hou ◽  
Lei Xia

The semi-rigid steel frame-composite steel plate shear wall structure (SCSW) effectively improves the lateral stiffness of shear wall, making it possible to use the semi-rigid joint. In order to study the plastic failure mechanism of SCSW, a plastic model is established, in which the effects of the rotations of semi-rigid joints and yield deformations of infill steel walls on the energy consumption are considered. Based on that, a design method for the lateral ultimate strength is put forward and a nonlinear FEM model is setup using ANSYS. Through the comparison between plastic analysis results with the finite element results, it is shown that the plastic analysis method is feasible and has a safe redundancy.


2018 ◽  
Vol 763 ◽  
pp. 743-750 ◽  
Author(s):  
Eduardo Totter ◽  
Antonio Formisano ◽  
Federico M. Mazzolani ◽  
Francisco Crisafulli

Unstiffened Steel Plate Shear Walls (SPSWs) are very effective structural systems designed to resist lateral forces. SPSW systems consist of thin web plates infilled within frames of steel horizontal and vertical boundary elements. The thin unstiffened web plates are expected to buckle in shear and to develop diagonal tension field after buckling under the action of horizontal loads. For unstiffened steel plates, buckling in shear occurs in the elastic range at low stress levels. This behaviour provides strength, stiffness and ductility and allows to have an appropriate level of energy dissipation through tension yielding of the web plates. This paper assesses the inelastic structural response and behaviour of Steel Plate Shear Wall systems using both a modified strip model approach and a new simplified strip model for only beam connected SPSWs. Both models are developed with plasticity concentrated elements and the performed analyses include the nonlinear behaviour of strips, also considering the compressive forces effects over the strip model elements. This research indicates fundamental aspects of the seismic performance of Steel Plate Shear Wall systems, such as energy dissipation capacity, panel ductility demand, seismic inter-story drift and design load demands in Vertical Boundary Elements (VBE) and Horizontal Boundary Elements (HBE) of the frame. The results obtained from the use of these models are compared with selected experimental and numerical results to enrich the research conclusions.


2018 ◽  
Vol 11 (3) ◽  
pp. 1-6
Author(s):  
Huda M. Najem

Steel plate shear wall (SPSW) is commonly used in civil schemes because of its good deformability and stiffness. In this research, the numerical analysis of steel plate shear wall (SPSW) with unstiffened infill steel plate is conducted. This paper explains the effect of thickness variation of infill steel plate on behavior of steel plate. In this status, several samples are designed and checked by rigid frame and actuator. The experimental samples is joined to a rigid frame. 3 numerical specimens consist of steel plate shear wall with different thickness (1.5, 3, 4. 5) mm formed by finite element code which is advanced by the Amirkabir university. To confirm the model, numerical results were discussed with a valid experiment which explain suitable agreement. Numerical model tested under cyclic loading with frequency of 1/60 Hz. Results show that the increase of infill steel plate thickness enhance stiffness and ductility ratio of model. And so, would decrease energy absorption in comparison with the reference model


For seismic design requirements, the major stress dispersing components for steel plate shear walls (SPSWs) that be resistant against lateral forces are un-hardened plates infilled (webs) that bend for shear then shape the sequence with diagonal tension field actions (TFAs). The tensile load of an infill plate must be resisted through the horizontal boundary elements (HBEs) and the vertical boundary elements (VBEs) surrounding every plates by means with its capacity design point of view. If rigid connections were established for both the HBEs and the VBEs as well as among VBEs even its base (when stated with other SPSW cases), the SPSWs often gain along with moment of resistance from another boundary element with that of its lateral horizontal forces deployed. Appreciating every usefulness by their boundary frame with their overall strength in that model, through their interest as can also occur in any form of optimizing the design of the SPSW, so instead of based for their appearance to this process for the over strength with which this can supply for withstand a defined lateral forces. About the lateral design, many aspects control its reaction to light – frame shear wall: rank the encasing elements, fastener style, fastener position, keep on low tightening system, size as well as the classification with the connected structural boards, existence frame connections, aspect ratio in the wall (height of the wall and length of the wall ratio), with wall attached components. While framing products and fastener forms vary throughout Cold – Formed Steel (CFS) as well as wood – frame shear wall mechanisms, a whole responds for those mechanisms also seem to be relatively equal when they are sufficiently comprehensive to resolve the material centric limit states. The steel plate shear wall (SPSW) arrangement seems to be recognized just like most among any simplest efficient ways for resistance of the lateral forces, specifically through seismic activity, the loads are adapted on the model. This comprises along with one steel plate infilled attached through an enclosed system throughout horizontal beams and vertical columns for the movement of lateral forces to the base of the foundation. Steel plate shear walls (SPSWs) column in mid – rise along with high – rise constructions typically needs an outsized compression capability, because it bear either an axial forces with gravitational forces of lateral forces and imposed by the moment of overturning. In order to ensure the effective usage with steel inward the plate infilled, and even will attain goodness as a whole earthquake output on that wall, that formed tension field need to have relatively consistent, requiring suitable anchoring by effective accompanying members of the frame. The lateral fore on the steel plate shear wall (SPSW) is determined by using American code.


2019 ◽  
Vol 2019 ◽  
pp. 1-11
Author(s):  
Yang Lv ◽  
Ling Li ◽  
Di Wu ◽  
Bo Zhong ◽  
Yu Chen ◽  
...  

Four scaled one-storey single-bay steel plate shear wall (SPSW) specimens with unstiffened panels were tested to determine their behaviour under cyclic loadings. The shear walls had moment-resisting beam-to-column connections. Four different vertical loads, i.e., 300 kN, 600 kN, 900 kN, and 1200 kN, representing the gravity load of the upper storeys were applied at the top of the boundary columns through a force distribution beam. A horizontal cyclic load was then applied at the top of the specimens. The specimen behaviour, envelope curves, axial stress distribution of the infill steel plate, and shear capacity were analyzed. The axial stress distribution and envelope curves were compared with the values predicted using an analytical model available in the literature.


Sign in / Sign up

Export Citation Format

Share Document