scholarly journals Efficiency of Optical Sensors with Quasi Gaussian Beam for Determining Cholesterol Concentration

Author(s):  
Mohammad Budiyanto ◽  
Suhariningsih Suhariningsih ◽  
Moh Yasin
2019 ◽  
Vol 9 (1) ◽  
pp. 22
Author(s):  
Mohammad Budiyanto ◽  
Mohamad Yasin ◽  
Sulaiman Wadi Harun

Sensitivity is the comparison result between changes in output signal intensity and changes in input signal shift sensor. The purpose of this study was to analyze the sensitivity of fiber optic sensors using mathematical analysis through the Gaussian beam approach and quasi-Gaussian beam compared with the sensitivity of the optical sensor experimental results so that it can find the correct approach of sensitivity values between theory and experiment. The research method used mathematical analysis and experimental methods and mathematical descriptions for the description of the bundle optical fiber used in the experiment until the sensitivity equation is obtained. The results of the mathematical analysis of the Gaussian beam sensitivity values obtained of S = 0.004 mV ppm-1 and the sensitivity of quasi-Gaussian beam of S = 0.08 mV ppm-1. The results of the sensitivity of experimentally obtained S = 0.11 mV ppm-1. Based on the results of mathematical, experimental analysis, and sensor performance, sensitivity through the flat mirror reflection field, it can be concluded that the sensitivity of the optical fiber sensor tends to approach through the quasi-Gaussian beam approach to determine cholesterol concentration.


VASA ◽  
2015 ◽  
Vol 44 (5) ◽  
pp. 355-362 ◽  
Author(s):  
Marie Urban ◽  
Alban Fouasson-Chailloux ◽  
Isabelle Signolet ◽  
Christophe Colas Ribas ◽  
Mathieu Feuilloy ◽  
...  

Abstract. Summary: Background: We aimed at estimating the agreement between the Medicap® (photo-optical) and Radiometer® (electro-chemical) sensors during exercise transcutaneous oxygen pressure (tcpO2) tests. Our hypothesis was that although absolute starting values (tcpO2rest: mean over 2 minutes) might be different, tcpO2-changes over time and the minimal value of the decrease from rest of oxygen pressure (DROPmin) results at exercise shall be concordant between the two systems. Patients and methods: Forty seven patients with arterial claudication (65 + / - 7 years) performed a treadmill test with 5 probes each of the electro-chemical and photo-optical devices simultaneously, one of each system on the chest, on each buttock and on each calf. Results: Seventeen Medicap® probes disconnected during the tests. tcpO2rest and DROPmin values were higher with Medicap® than with Radiometer®, by 13.7 + / - 17.1 mm Hg and 3.4 + / - 11.7 mm Hg, respectively. Despite the differences in absolute starting values, changes over time were similar between the two systems. The concordance between the two systems was approximately 70 % for classification of test results from DROPmin. Conclusions: Photo-optical sensors are promising alternatives to electro-chemical sensors for exercise oximetry, provided that miniaturisation and weight reduction of the new sensors are possible.


1980 ◽  
Vol 41 (8) ◽  
pp. 837-844 ◽  
Author(s):  
F. Rohart ◽  
B. Macke
Keyword(s):  

1986 ◽  
Vol 55 (02) ◽  
pp. 173-177 ◽  
Author(s):  
K Desai ◽  
J S Owen ◽  
D T Wilson ◽  
R A Hutton

SummaryPlatelet aggregation, platelet lipid composition and plasma lipoprotein concentrations were measured each week in a group of seventeen alcoholics, without overt liver disease, for one month, following acute, total alcohol withdrawal. The platelets were initially hypoaggregable but, within 1-2 weeks of cessation of drinking, they became hyperaggregable and then gradually returned towards normal values. Hyperaggregability could not be explained by increases in either the cholesterol or the arachidonic acid content of the platelets. Plasma very-low-density lipoprotein cholesterol levels remained high throughout the study, but the initially raised levels of high-density lipoprotein (HDL) cholesterol fell by 26%. Low-density lipoprotein (LDL) cholesterol concentration rose by 10% after two weeks of withdrawal but then returned to about the starting level. The resulting changes in the plasma LDL-cholesterol: HDL-cholesterol ratio, which had increased by more than 50% after two weeks of abstinence, essentially paralleled the time course of enhanced platelet reactivity in all but four of the alcoholics. These findings suggest that alterations in plasma lipoprotein concentrations during acute alcohol withdrawal may be a contributory factor to the haemostatic disorders present in such patients.


2020 ◽  
pp. 38-44
Author(s):  
A. V. Polyakov ◽  
M. A. Ksenofontov

Optical technologies for measuring electrical quantities attract great attention due to their unique properties and significant advantages over other technologies used in high-voltage electric power industry: the use of optical fibers ensures high stability of measuring equipment to electromagnetic interference and galvanic isolation of high-voltage sensors; external electromagnetic fields do not influence the data transmitted from optical sensors via fiber-optic communication lines; problems associated with ground loops are eliminated, there are no side electromagnetic radiation and crosstalk between the channels. The structure and operation principle of a quasi-distributed fiber-optic high-voltage monitoring system is presented. The sensitive element is a combination of a piezo-ceramic tube with an optical fiber wound around it. The device uses reverse transverse piezoelectric effect. The measurement principle is based on recording the change in the recirculation frequency under the applied voltage influence. When the measuring sections are arranged in ascending order of the measured effective voltages relative to the receiving-transmitting unit, a relative resolution of 0,3–0,45 % is achieved for the PZT-5H and 0,8–1,2 % for the PZT-4 in the voltage range 20–150 kV.


1961 ◽  
Vol 38 (1) ◽  
pp. 73-87 ◽  
Author(s):  
Christian Lauritzen ◽  
Semih Velibese

ABSTRACT A description is given of experimental investigations and preliminary clinical experience with the long-acting oestriol compound polyoestriol phosphate – a water-soluble polymere of oestriol and phosphoric acid. The compound seems to exert all the physiologically important effects of oestriol. Even with high doses the hormone causes no proliferation of the endometrium and no withdrawal bleeding. It has no untoward effect on metabolism. It decreases slightly the cholesterol concentration (to the extent of ⅓–⅕ of the effect produced by long-acting oestradiol esters). The compound has a wide therapeutic range. No side-effects have been observed. Doses of 10 mg or more have a prolonged duration. Additional prolongation of the effect is largely dependent on dosage. To ensure an effect lasting for 4 weeks 40 mg polyoestriol phosphate (corresponding with 30 mg oestriol) is required – an amount which roughly corresponds with physiological quantitative data. The compound, which involves an interesting new principle of prolongation, was most effectively used in the treatment of menopausal symptoms and genital organic disorders. For these indications it can be recommended without reservation.


2004 ◽  
Vol 9 (1) ◽  
pp. 55-63
Author(s):  
V. Kleiza

Light transmission in the reflection fiber system, located in external optical media, has been investigated for application as sensors. The system was simulated by different models, including external cavity parameters such as the distance between light emitting and receiving fibers and mirror positioning distance. The sensitivity to a linear displacement of the sensors was studied as a function of the distance between the tips of the light emitting fiber and the center of the pair reflected light collecting fibers, by positioning a mirror. Physical fundamentals and operating principles of the advanced fiber optical sensors were revealed.


Sign in / Sign up

Export Citation Format

Share Document