scholarly journals Development and Research of Electrochemical Cells of Gas Analyzers for Determination of Carbon Oxide in Gas Media

The method for determining the concentration of carbon oxide in vapor-gas mixtures, based on the method of controlled potential amperometry, which belongs to the category of absolute measurement methods, is proposed. Metrological characteristics of electrochemical cells: with diffusion supply of the analyzed gas; with diffusion gas supply; with condensed electrolyte and forced gas supply have been developed and studied

2020 ◽  
Vol 65 (7-8) ◽  
pp. 37-41
Author(s):  
E. N. Semenova ◽  
S. I. Kuleshova ◽  
E. I. Sakanyan

A method for the quantitative determination of streptomycin sulfate in medicines by the turbidimetric method has been developedand validated. Based on the results of the experiments, it was found that the metrological characteristics of such validation parameters of the method as linearity, precision, and correctness do not exceed the validation criteria. Linearity was noted in the range of streptomycin concentrations from 3.75 to 8.43 μg/ml. The results of validation tests of the method for the quantitative determination of streptomycin indicate the prospects and feasibility of introducing the turbidimetric method into the domestic system for standardization and quality assessment of aminoglycoside antibiotics.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Karine Arrhenius ◽  
Oliver Büker

AbstractThe study presents an optimised method to correct flow rates measured with a LFE flowmeter pre-set on methane while used for gas mixtures of unknown composition at the time of the measurement. The method requires the correction of the flow rate using a factor based on the viscosity of the gas mixtures once the composition is accurately known. The method has several different possible applications inclusive for the sampling of biogas and biomethane onto sorbent tubes for conformity assessment for the determination of siloxanes, terpenes and VOC in general. Five models for the calculation of the viscosity of the gas mixtures were compared and the models were used for ten binary mixtures and four multi-component mixtures. The results of the evaluation of the different models showed that the correction method using the viscosity of the mixtures calculated with the model of Reichenberg and Carr showed the smallest biases for binary mixtures. For multi-component mixtures, the best results were obtained when using the models of Lucas and Carr.


Sign in / Sign up

Export Citation Format

Share Document