scholarly journals HPLC method for the development and validation of busulfan in pharmaceutical formulation

2021 ◽  
Vol 6 (3) ◽  
pp. 136-142
Author(s):  
K Swamy Sekhar ◽  
Ch Venkata kishore ◽  
V Tejeswara Rao ◽  
K. Raghu Babu

A validated HPLC method was developed for the determination of Busulfan (BUS) in pharmaceutical formulation.It is a new simple, accurate, precise and reproducible HPLC method has been developed for the estimation of Busulfan (1,4-butanediol dimethanesulfonate) in its inject able dosage.The method developed in High Performance Liquid Chromatographic method using suitable column (YMC Pack ODS-A (150 x 4.6) mm, 3µm). All the components of the system are controlled using SCL-10Avp System Controller. Data acquisition was done using LC Solutions software.The method was validated as per the ICH guidelines. Thus, the proposed HPLC method can be successfully applied for the routine quality control analysis of formulations. The method developed is simple and is better than the methods reported in the literature and the method is capable to give a good detector response, the recovery calculated was within the range of 98% to 102% of the specification limits.

INDIAN DRUGS ◽  
2012 ◽  
Vol 49 (05) ◽  
pp. 61-64
Author(s):  
A. L Rao ◽  
◽  
R. V Bhaskara

A reverse phase high performance liquid chromatographic method was developed and validated asper ICH guidelines for estimation of trandolapril and verapamil in combined tablet dosage form. Theseparation was obtained using a mobile phase consisting of acetonitrile and phosphate buffer adjustingpH to 3.0 in the ratio of 70:30 v/v and using Waters C18 (250 x 4.6 mm, 5 mcm) column maintained atambient temperature. The flow rate was 1.2 mL min-1 and UV detection was monitored at 215 nm. Theretention time (min) and linearity range (mcg mL-1) for trandolapril and verapamil were (5.12, 2.70) and(20-60, 20-60), respectively. The method validation results are within the acceptance criteria for precision,accuracy and linearity. The proposed method was found to be suitable for routine quality control ofmarketed formulation containing these APIs.


2010 ◽  
Vol 7 (4) ◽  
pp. 1621-1627 ◽  
Author(s):  
Yunoos Mohammad ◽  
B. Pragati Kumar ◽  
Azmath Hussain ◽  
Harish

A simple, rapid, accurate, precise and reproducible reverse phase high performance liquid chromatographic method has been developed for the estimation of gemifloxacin mesylate in bulk and pharmaceutical formulations. The quantification was carried out using cyberlab capcell pak, ODS C18(250 × 4.6 mm i.d., 5 μm particle size) column in an isocratic mode, with mobile phase comprising Buffer (KH2PO4with pH 6.8): acetonitrile in the ratio of 80:20 (%v/v).The flow rate was at 1.2 mL/min and the detection was carried out at 265 nm. The retention time of the drug was found to be 7.47 min and the method produced linear response in the concentration range of 25-150 μg/mL (R∼0.99986). The recovery studies were also carried out and % RSD from reproducibility was found to be 0.82. The proposed method was statistically evaluated and can be applied for routine quality control analysis of gemifloxacin mesylate in tablets.


INDIAN DRUGS ◽  
2021 ◽  
Vol 58 (07) ◽  
pp. 32-37
Author(s):  
Vijaya Lakshmi Marella ◽  
Chaitanya S. N ◽  

A selective and sensitive reverse phase High Performance Liquid Chromatographic method has been developed and validated for the estimation of lornoxicam in bulk, pharmaceutical dosage forms and in dissolution samples. The analysis was performed isocratically on an Inertsil column (250* 4.6 mm, 5 µm) using a mass spectrometric compatible mobile phase of 10 mM ammonium acetate: acetonitrile (50:50 V/V) at a flow rate of 1 mL/min.The detection wavelength was 290 nm. The retention time was found to be 4.573 min for lornoxicam. The linearity of the method has been satisfied with Beer Lambert’s law in the concentration range of 5-25 µg/mL with a correlation coefficient of 0.9988. The mean recoveries assessed for lornoxicam were in the range of 100.39-101.86 %, indicating good accuracy of the method. The limit of detection and limit of quantification were found to be 0.03 and 0.11 µg/mL, respectively. The developed method has been statistically validated in accordance with ICH guidelines and found to be mass spectrometric compatible, simple, precise, and accurate with the prescribed values. Thus, the proposed method was successfully applied for the estimation of lornoxicam in routine quality control analysis of bulk, formulations and in dissolution samples.


INDIAN DRUGS ◽  
2018 ◽  
Vol 55 (06) ◽  
pp. 63-68
Author(s):  
R. Raut ◽  
◽  
A. Patil ◽  
V. K Munipalli ◽  
M. Patel ◽  
...  

A simple precise and rapid Reverse Phase High Performance Liquid Chromatographic (RP-HPLC) method has been developed for quantitative determination of Regorafenib in tablet dosage form. In this method Hypersil Gold (C18, 150mm× 4.6mm id, 3μ) column with mobile phase consisting of Trifluoroacetic acid (0.2% v/v) and Acetonitrile in the ratio of (50: 50 v/v) at 400C in an isocratic mode was used. The detection was carried out at 260 nm and 20μL injection volume was selected with the flow rate 1mL/min. The linearity range of Regorafenib shows concentration between 5-200 μg/mL. The regression coefficient obtained was 0.999. Retention time of Regorafenib was found to be 6.49 minutes. Acetonitrile and Water in the ratio of (3:1) was used as a diluent. The method was validated as per ICH guidelines and is simple, fast, accurate, precise and can be applied for routine quality control analysis of Regorafenib in tablet dosage form.


INDIAN DRUGS ◽  
2019 ◽  
Vol 56 (07) ◽  
pp. 43-49
Author(s):  
B.P. Manjula ◽  
V. G Joshi ◽  
Siddamsetty Ramachandra Setty ◽  
M Geetha ◽  

Tea tree oil, an active ingredient of skin, hair and nail care cosmeceuticals, has claims for topical antimicrobial, analgesic and anti-inflammatory activity. Its complex composition is governed by ISO 4730:2017. Terpinene-4-ol is the principal constituent of the oil (35% - 48%) followed by γ-terpinene (14% -28%), α-terpinene (6%-12%) and 1,8-cineole (≤15%). A reversed-phase, isocratic high performance liquid chromatographic method has been developed and validated for routine determination of tea tree oil based on1,8-cineole content in bulk and commercially available cosmeceuticals using C18 column, methanol-water (70:30 v/v) as mobile phase and flow rate of 1mL/min. UV detection was done at 200 nm. Linearity of the method was established for 20-100μL/mL (R2 = 0.9992) with LOD, LOQ values of 0.5594 μL/mL and 5.5941μL/mL respectively. The % RSD values for robustness and precision were <1% and recovery ranged between 99.09-102.96%. The method was successfully applied for determination of 1,8-cineole content in cosmeceuticals.


Author(s):  
M. Murali ◽  
P. Venkateswara Rao

A simple, selective, linear, precise and accurate isocratic RP-HPLC method was developed and validated for rapid assay of Vandetanib, an anticancer drug, in both bulk and tablet dosage form. Elution at a flow rate of 1ml/min was employed on a symmetry C18 column at ambient temperature. The mobile phase consisted of acetonitrile, water and orthophosphoric acid in the ratio of 90:08:02 (v/v/v). Linearity was observed in concentration range of 50-200 ppm. The retention time for Vandetanib was 3.326 min. The method was validated as per the ICH guidelines. The proposed method can be successfully applied for the estimation of Vandetanib in pharmaceutical dosage forms. Moreover the detection alone was also verified through LC-MS of the Vandetanib drug using ESI method which provides future scope for study of this drug using LC-MS method also.


Author(s):  
Zahid Zaheer ◽  
Sarfaraz Khan ◽  
Mohammad Sadeque ◽  
Hundekari G. I. ◽  
Rana Zainuddin

A simple, reproducible and efficient reverse phase high performance liquid chromatographic method was developed for Lisinopril in bulk drug and formulation. A column having 150 × 4.6 mm in isocratic mode with mobile phase containing acetonitrile: phosphate buffer (70:30; adjusted to pH 3.0) was used. The flow rate was 0.8 ml/min and effluent was monitored at 216 nm. The retention time (min) and linearity range (μg/ml) for Lisinopril was (1.510) and (10-35). The developed method was found to be accurate, precise and selective for determination of Lisinopril in bulk and formulation.


2017 ◽  
Vol 1 (2) ◽  
pp. 1-8
Author(s):  
Milena Cristina Ribeiro Souza Magalhães ◽  
Alisson Samuel Portes Caldeira ◽  
Hanna De Sousa Rocha Almeida ◽  
Sílvia Ligório Fialho ◽  
Armando Da Silva Cunha Junior

A reversed-phase high-performance liquid chromatographic (HPLC) method was developed and validated for the determination of encapsulation efficiency of zidovudine in nanoparticules. The method was carried out in isocratic mode using 0.040M sodium acetate: methanol: acetonitrile: glacial acetic acid (880:100:20:2) as mobile phase, a C8 column at 25ºC and UV detection at 240 nm. The method was linear (r2 ˃ 0.99) over the range of 25.0-150.0 μg/mL, precise (RSD ˂ 5%), accurate (recovery = 100.5%), robust and selective. The validated HPLC-UV method can be successfully applied to determine the rate of zidovudine in nanoparticules.


Author(s):  
Abrar Ahmed ◽  
Tayyaba Mahtab ◽  
Sumaiyya Saleem

Midostaurin is a multi-targeted protein kinase inhibitor that has been used for the treatment of acute myeloid leukemia.  Here, a rapid and precise reverse phase high-performance liquid chromatographic method has been developed for the validation of midostaurin, in its API form as well as in capsule dosage form. Chromatography was carried out on a X-Bridge C18 (4.6 x 250 mm, 5 µm) column using a mixture of methanol: water (75:25% v/v) as the mobile phase at a flow rate of 1.0 mL/min, the detection was carried out at 243nm and the retention time of the midostaurin was found to be 3.155. The method produce linear responses in the concentration range of 10-50 µg/mL of midostaurin. The method precision for the determination of assay was below 2.0 % RSD. The LOD and LOQ values obtained were 1.2 µg/mL and 3.8 µg/mL respectively. There were no significant changes observed upon changing chromatographic conditions indicating the method to be robust. Therefore this validated method can be useful in the quality control of bulk and pharmaceutical formulations of midostaurin. 


2010 ◽  
Vol 7 (2) ◽  
pp. 600-604 ◽  
Author(s):  
A. Lakshmana Rao ◽  
V. Naga Jahnavi

A rapid and sensitive high performance liquid chromatographic method was developed for the estimation of levetiracetam in bulk and pharmaceutical formulations. Levetiracetam was chromatographed on a reverse phase C18column in a mobile phase consisting of 0.05 M KH2PO4buffer (pH 3.0 adjusted with orthophosphoric acid) and methanol in the ratio 70:30 v/v. The mobile phase was pumped at a flow rate of 1.2 mL/min. with detection at 210 nm. The detector response was linear in the concentration of 20-120 μg/mL. The limit of detection and limit of quantification was found to be 0.0104 and 0.0317 μg/mL, respectively. The intra and inter day variation was found to be less than 1%. The mean recovery of the drug from the solution containing 100 µg/mL was 100.038 μg/mL. The proposed method is simple, fast, accurate, precise and reproducible hence can be applied for routine quality control analysis of levetiracetam in bulk and pharmaceutical formulations.