DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR THE ESTIMATION OFTRANDOLAPRIL AND VERAPAMIL IN COMBINED TABLET DOSAGE FORM

INDIAN DRUGS ◽  
2012 ◽  
Vol 49 (05) ◽  
pp. 61-64
Author(s):  
A. L Rao ◽  
◽  
R. V Bhaskara

A reverse phase high performance liquid chromatographic method was developed and validated asper ICH guidelines for estimation of trandolapril and verapamil in combined tablet dosage form. Theseparation was obtained using a mobile phase consisting of acetonitrile and phosphate buffer adjustingpH to 3.0 in the ratio of 70:30 v/v and using Waters C18 (250 x 4.6 mm, 5 mcm) column maintained atambient temperature. The flow rate was 1.2 mL min-1 and UV detection was monitored at 215 nm. Theretention time (min) and linearity range (mcg mL-1) for trandolapril and verapamil were (5.12, 2.70) and(20-60, 20-60), respectively. The method validation results are within the acceptance criteria for precision,accuracy and linearity. The proposed method was found to be suitable for routine quality control ofmarketed formulation containing these APIs.

Author(s):  
E. Amulya ◽  
N. Naveen Kumar ◽  
CH. Mounika ◽  
V. Kowmudi ◽  
N. Supriya ◽  
...  

A rapid and precise reverse phase high performance liquid chromatographic method has been developed for the validated of Trihexyphenidyl and Haloperidol, in its pure form as well as in tablet dosage form. Chromatography was carried out on a Altima C18 (4.6 x 150mm, 5μm) column using a mixture of Methanol: TEA Buffer pH 4.5: Acetonitrile (50:25:25) as the mobile phase at a flow rate of 1.0ml/min, the detection was carried out at 225 nm. The retention time of the Trihexyphenidyl and Haloperidol was 2.102, 3.537±0.02min respectively. The method produce linear responses in the concentration range of 15-75ppm of Trihexyphenidyland 37.5-187.5ppm of Haloperidol. The method precision for the determination of assay was below 2.0%RSD. The method is useful in the quality control of pharmaceutical formulations.


Author(s):  
Sireesha D ◽  
Sai Lakshmi E ◽  
Sravya E ◽  
Vasudha Bakshi

A new simple, rapid, specific, accurate, precise and novel Reverse Phase High Performance Liquid Chromatography (RP-HPLC) method has been developed for the estimation of Sitagliptin Phosphate in the pharmaceutical dosage form. The chromatographic separation for Sitagliptin was achieved with mobile phase containing methanol, Thermoscientific C18 column, (250x4.6 particle size of 5μ) at room temperature and UV detection at 248 nm. The compounds were eluted in the isocratic mode at a flow rate of 1ml/min. The retention time of Sitagliptin was 1.91min. The above method was validated in terms of linearity, accuracy, precision, LOD and LOQ in accordance with ICH guidelines.


INDIAN DRUGS ◽  
2018 ◽  
Vol 55 (06) ◽  
pp. 63-68
Author(s):  
R. Raut ◽  
◽  
A. Patil ◽  
V. K Munipalli ◽  
M. Patel ◽  
...  

A simple precise and rapid Reverse Phase High Performance Liquid Chromatographic (RP-HPLC) method has been developed for quantitative determination of Regorafenib in tablet dosage form. In this method Hypersil Gold (C18, 150mm× 4.6mm id, 3μ) column with mobile phase consisting of Trifluoroacetic acid (0.2% v/v) and Acetonitrile in the ratio of (50: 50 v/v) at 400C in an isocratic mode was used. The detection was carried out at 260 nm and 20μL injection volume was selected with the flow rate 1mL/min. The linearity range of Regorafenib shows concentration between 5-200 μg/mL. The regression coefficient obtained was 0.999. Retention time of Regorafenib was found to be 6.49 minutes. Acetonitrile and Water in the ratio of (3:1) was used as a diluent. The method was validated as per ICH guidelines and is simple, fast, accurate, precise and can be applied for routine quality control analysis of Regorafenib in tablet dosage form.


INDIAN DRUGS ◽  
2015 ◽  
Vol 52 (08) ◽  
pp. 12-16
Author(s):  
S Vidyadhara ◽  
◽  
L. S Reddyvalam ◽  
T. Koduri ◽  
P. K. Borra ◽  
...  

A simple, accurate, precise high-performance liquid chromatographic (HPLC) method has been developed and validated for the simultaneous determination of abacavir sulphate (ABA) and lamivudine (LAM) in combined dosage form. Separation was performed on a C18 column [Agilent ODS UG 5 column, 250 mm x 4.5 mm], with methanol: water (50:50 V/V) isocratic elution using a flow rate of 1mL/min. Good sensitivity was observed with UV detection at 277 nm. After method development, the interference of other active compounds and excipients, repeatability and linearity, were investigated. Retention times of LAM and ABA were found to be 3.3 and 6.3 min, respectively. The method was validated over the range from 2.5-12.5 μg/mL for LAM and 5-25 μg/mL for ABA with correlation coefficients of 0.9997 and 0.9996, respectively. This method was shown to be accurate, robust, selective, linear, and repeatable and can be successfully employed in routine quality control for the simultaneous analysis of ABA and LAM in tablets.


2017 ◽  
Vol 4 (1) ◽  
pp. 5-10 ◽  
Author(s):  
Ramesh Jayaprakash ◽  
Senthil Kumar Natesan

A simple, economic, accurate, sensitive, specific and precise stability indicating reverse phase high performance liquid chromatographic [RP-HPLC] method for the determination of Regorafenib in pure and tablet dosage from was developed and validated. The chromatographic separation was carried out using Phenomenex Luna-C18 column (4.5x250 mm; 5 µm particle size) as a stationary phase and methanol: acetonitrile: water (55:25:20 v/v/v) as a mobile phase. The flow rate of 1 mL/min was used with PDA detection at 275 nm. The retention time of Regorafenib was 2.480 min. RP-HPLC method was developed with linearity range of 40-240 µg/mL of Regorafenib. The correlation coefficient [r2] was found to be 0.9999. The assay results obtained was in good agreement with the corresponding labeled amount by developed method within range of 98.83 ± 0.6937. Accuracy of the method was confirmed by recovery studies and the recoveries were found to be between 99.61 % and 100.22 %, the corresponding %RSD was found to be 0.2029. Precision, LOD, LOQ, specificity, robustness and ruggedness were performed as per ICH Q2(R1) guidelines and were within the acceptance criteria. This method can be conveniently used to detect the possible degradation product in the dosage form of Regorafenib during stability studies (acidic, alkaline, oxidative, thermal and photolytic). The method proved to be effective on the analysis of stressed marketed tablet formulation.


2021 ◽  
Vol 6 (3) ◽  
pp. 136-142
Author(s):  
K Swamy Sekhar ◽  
Ch Venkata kishore ◽  
V Tejeswara Rao ◽  
K. Raghu Babu

A validated HPLC method was developed for the determination of Busulfan (BUS) in pharmaceutical formulation.It is a new simple, accurate, precise and reproducible HPLC method has been developed for the estimation of Busulfan (1,4-butanediol dimethanesulfonate) in its inject able dosage.The method developed in High Performance Liquid Chromatographic method using suitable column (YMC Pack ODS-A (150 x 4.6) mm, 3µm). All the components of the system are controlled using SCL-10Avp System Controller. Data acquisition was done using LC Solutions software.The method was validated as per the ICH guidelines. Thus, the proposed HPLC method can be successfully applied for the routine quality control analysis of formulations. The method developed is simple and is better than the methods reported in the literature and the method is capable to give a good detector response, the recovery calculated was within the range of 98% to 102% of the specification limits.


Author(s):  
M. Murali ◽  
P. Venkateswara Rao

A simple, selective, linear, precise and accurate isocratic RP-HPLC method was developed and validated for rapid assay of Vandetanib, an anticancer drug, in both bulk and tablet dosage form. Elution at a flow rate of 1ml/min was employed on a symmetry C18 column at ambient temperature. The mobile phase consisted of acetonitrile, water and orthophosphoric acid in the ratio of 90:08:02 (v/v/v). Linearity was observed in concentration range of 50-200 ppm. The retention time for Vandetanib was 3.326 min. The method was validated as per the ICH guidelines. The proposed method can be successfully applied for the estimation of Vandetanib in pharmaceutical dosage forms. Moreover the detection alone was also verified through LC-MS of the Vandetanib drug using ESI method which provides future scope for study of this drug using LC-MS method also.


Author(s):  
Zahid Zaheer ◽  
Sarfaraz Khan ◽  
Mohammad Sadeque ◽  
Hundekari G. I. ◽  
Rana Zainuddin

A simple, reproducible and efficient reverse phase high performance liquid chromatographic method was developed for Lisinopril in bulk drug and formulation. A column having 150 × 4.6 mm in isocratic mode with mobile phase containing acetonitrile: phosphate buffer (70:30; adjusted to pH 3.0) was used. The flow rate was 0.8 ml/min and effluent was monitored at 216 nm. The retention time (min) and linearity range (μg/ml) for Lisinopril was (1.510) and (10-35). The developed method was found to be accurate, precise and selective for determination of Lisinopril in bulk and formulation.


2014 ◽  
Vol 2014 ◽  
pp. 1-5 ◽  
Author(s):  
Patel Bhaumik ◽  
Gopani Mehul ◽  
Vikani Kartik ◽  
Patel Rashmin ◽  
Patel Mrunali

This paper describes validated reverse phase high-performance liquid chromatographic (RP-HPLC) method for simultaneous estimation of trihexyphenidyl hydrochloride (THP) and risperidone (RSP) in the pure powder form and in combined tablet dosage form. The HPLC separation was achieved on a core shell C18 (100 mm length × 4.6 mm, 2.6 μm particle size) using methanol : ammonium acetate buffer 1% (85 : 15 v/v; pH-6.5) as mobile phase and delivered at flow rate of 0.8 mL/min. The calibration plot showed good linear relationship with r2 = 0.997 ± 0.001 for THP and r2 = 0.998 ± 0.001 for RSP in concentration range of 50–175 μg/mL and 50–175 μg/mL, respectively. LOD and LOQ were found to be 0.40 and 1.29 μg/mL for THP and 1.24 and 3.92 μg/mL for RSP. Assay of THP and RSP was found to be 100.16 ± 0.03% and 99.83 ± 0.02%, respectively. THP and RSP were subjected to different stress conditions (acidic, basic, oxidative, thermal, and photolytic degradation). The degraded product peaks were well resolved from the pure drug peak. The method was successfully validated as per the ICH guidelines. The developed RP-HPLC method was successfully applied for the estimation of THP and RSP in tablet dosage form.