scholarly journals Inclusion of solar energy in iraq gas-turbine power plants as a method of solving the country's energy system shortage

Author(s):  
A. Z. Abass ◽  
D. A. Pavlyuchenko ◽  
A. M. Balabanov ◽  
V. M. Less

At high ambient temperatures, the performance of gas turbine power plants drops significantly. Technical solutions of compensation for losses associated with the constant injection of water into the air intake of a gas turbine. This approach is not acceptable in regions with limited fresh water reserves. Radical solutions are required to reduce the cost of generated energy. Integrated Combined Solar Cycle (ISCCS) technology has proven itself on many projects. The addition of a combined cycle gas cycle with solar energy can significantly increase the overall efficiency of the power plant. Despite the increase in costs during the construction of its solar part, the total cost of operating solar collectors is several times less than a turbine installation. Given the global trend to fight carbon emissions, switching to a hybrid scheme is economically attractive. Trading in carbon credits for CO2 emissions will significantly reduce the payback period for the construction of gas turbine modernization under the ISCCS scheme. This paper presents an option to modernize a gas turbine power plant in the city of Basra (Iraq), using the advantages of solar radiation and recycling of combustion products from gas turbines. It is proposed to equip the existing 200 MW gas turbine plant with two steam turbine units with a capacity of 75 and 65 MW, working in conjunction with solar collectors producing low pressure water vapor. Due to modernization, the efficiency of the power plant should increase from 38% to 55%. The revision of the schematic and technical solutions of Iraq power plants will allow producing sufficient energy for the region.

2021 ◽  
Vol 286 ◽  
pp. 04013
Author(s):  
George Iulian Balan ◽  
Octavian Narcis Volintiru ◽  
Ionut Cristian Scurtu ◽  
Florin Ioniță ◽  
Mirela Letitia Vasile ◽  
...  

Vessels that have navigation routes in areas with ambient temperatures that can drop below + 5 [°C], with a relative humidity of over 65%, will have implemented technical solutions for monitoring and combating ice accumulations in the intake routes of gas turbine power plants. Because gas turbines are not designed and built to allow the admission of foreign objects (in this case - ice), it is necessary to avoid the accumulation of ice through anti-icing systems and not to melt ice through defrost systems. Naval anti-icing systems may have as a source of energy flow compressed air, supersaturated steam, exhaust gases, electricity or a combination of those listed. The monitoring and optimization of the operation of the anti-icing system gives the gas turbine power plant an operation as close as possible to the normal regimes stipulated in the ship's construction or retrofit specification.


Author(s):  
Christian Engelbert ◽  
Joseph J. Fadok ◽  
Robert A. Fuller ◽  
Bernd Lueneburg

Driven by the requirements of the US electric power market, the suppliers of power plants are challenged to reconcile both plant efficiency and operating flexibility. It is also anticipated that the future market will require more power plants with increased power density by means of a single gas turbine based combined-cycle plant. Paramount for plant efficiency is a highly efficient gas turbine and a state-of-the-art bottoming cycle, which are well harmonized. Also, operating and dispatch flexibility requires a bottoming cycle that has fast start, shutdown and cycling capabilities to support daily start and stop cycles. In order to meet these requirements the author’s company is responding with the development of the single-shaft 1S.W501G combined-cycle power plant. This nominal 400MW class plant will be equipped with the highly efficient W501G gas turbine, hydrogen-cooled generator, single side exhausting KN steam turbine and a Benson™ once-through heat recovery steam generator (Benson™-OT HRSG). The single-shaft 1S.W501G design will allow the plant not only to be operated economically during periods of high demand, but also to compete in the traditional “one-hour-forward” trading market that is served today only by simple-cycle gas turbines. By designing the plant with fast-start capability, start-up emissions, fuel and water consumption will be dramatically reduced. This Reference Power Plant (RPP) therefore represents a logical step in the evolution of combined-cycle power plant designs. It combines both the experiences of the well-known 50Hz single-shaft 1S.V94.3A plant with the fast start plant features developed for the 2.W501F multi-shaft RPP. The paper will address results of the single-shaft 1S.W501G development program within the authors’ company.


Author(s):  
W. Peter Sarnacki ◽  
Richard Kimball ◽  
Barbara Fleck

The integration of micro turbine engines into the engineering programs offered at Maine Maritime Academy (MMA) has created a dynamic, hands-on approach to learning the theoretical and operational characteristics of a turbojet engine. Maine Maritime Academy is a fully accredited college of Engineering, Science and International Business located on the coast of Maine and has over 850 undergraduate students. The majority of the students are enrolled in one of five majors offered at the college in the Engineering Department. MMA already utilizes gas turbines and steam plants as part of the core engineering training with fully operational turbines and steam plant laboratories. As background, this paper will overview the unique hands-on nature of the engineering programs offered at the institution with a focus of implementation of a micro gas turbine trainer into all engineering majors taught at the college. The training demonstrates the effectiveness of a working gas turbine to translate theory into practical applications and real world conditions found in the operation of a combustion turbine. This paper presents the efforts of developing a combined cycle power plant for training engineers in the operation and performance of such a plant. Combined cycle power plants are common in the power industry due to their high thermal efficiencies. As gas turbines/electric power plants become implemented into marine applications, it is expected that combined cycle plants will follow. Maine Maritime Academy has a focus on training engineers for the marine and stationary power industry. The trainer described in this paper is intended to prepare engineers in the design and operation of this type of plant, as well as serve as a research platform for operational and technical study in plant performance. This work describes efforts to combine these laboratory resources into an operating combined cycle plant. Specifically, we present efforts to integrate a commercially available, 65 kW gas turbine generator system with our existing steam plant. The paper reviews the design and analysis of the system to produce a 78 kW power plant that approaches 35% thermal efficiency. The functional operation of the plant as a trainer is presented as the plant is designed to operate with the same basic functionality and control as a larger commercial plant.


Author(s):  
Jaya Ganjikunta

Market demands such as generating power at lower cost, increasing reliability, providing fuel flexibility, increasing efficiency and reducing emissions have renewed the interest in Integrated Gasification Combined Cycle (IGCC) plants in the Indian refinery segment. This technology typically uses coal or petroleum coke (petcoke) gasification and gas turbine based combined cycle systems as it offers potential advantages in reducing emissions and producing low cost electricity. Gasification of coal typically produces syngas which is a mixture of Hydrogen (H) and Carbon Monoxide (CO). Present state of gas turbine technology facilitates burning of low calorific fuels such as syngas and gas turbine is the heart of power block in IGCC. Selecting a suitable gas turbine for syngas fired power plant application and optimization in integration can offer the purchaser savings in initial cost by avoiding oversizing as well as reduction in operating cost through better efficiency. This paper discusses the following aspects of syngas turbine IGCC power plant: • Considerations in design and engineering approach • Review of technologies in syngas fired gas turbines • Design differences of syngas turbines with respect to natural gas fired turbines • Gas turbine integration with gasifier, associated syngas system design and materials • Syngas safety, HAZOP and Hazardous area classification • Retrofitting of existing gas turbines suitable for syngas firing • Project execution and coordination at various phases of a project This paper is based on the experience gained in the recently executed syngas fired gas turbine based captive power plant and IGCC plant. This experience would be useful for gas turbine technology selection, integration of gas turbine in to IGCC, estimating engineering efforts, cost savings, cycle time reduction, retrofits and lowering future syngas based power plant project risks.


Author(s):  
S. Can Gulen ◽  
Raub W. Smith

A significant portion of the new electrical generating capacity installed in the past decade has employed heavy-duty gas turbines operating in a combined cycle configuration with a steam turbine bottoming cycle. In these power plants approximately one third of the power is generated by the bottoming cycle. To ensure that the highest possible combined cycle efficiency is realized it is important to develop the combined cycle power plant as a system. Doing so requires a solid understanding of the efficiency entitlement of both, topping and bottoming, cycles separately and as a whole. This paper describes a simple but accurate method to estimate the Rankine bottoming cycle power output directly from the gas turbine exhaust exergy utilizing the second law of thermodynamics. The classical first law approach, i.e. the heat and mass balance method, requires lengthy calculations and complex computer-based modeling tools to evaluate Rankine bottoming cycle performance. In this paper, a rigorous application of the fundamental thermodynamic principles embodied by the second law to the major cycle components clearly demonstrates that the Rankine cycle performance can be accurately represented by several key parameters. The power of the second law approach lies in its ability to highlight the theoretical entitlement and state-of-the-art design performances simultaneously via simple, fundamental relationships. By considering economically and technologically feasible upper limits for the key parameters, the maximum achievable bottoming cycle power output is readily calculable for any given gas turbine from its exhaust exergy.


2018 ◽  
Vol 3 (7) ◽  
pp. 50
Author(s):  
Anthony Kpegele Le-ol ◽  
Sidum Adumene ◽  
Kenneth Israel

This work presents a comparative analysis of the thermo-economic performance of a simple, retrofitted and built-in combined cycle power plants within the Delta. The data were obtained from a 25MW gas turbine plant-based engine, retrofitted and MATLAB software was used to model the thermodynamic performance of the plants. The economic prediction of the plants was done using a developed net present value(NPV), internal rate of return (IRR), cost of investment (COR) and payback period (PBP).  The economic concept for plants performance was analysed under uncertainty constraints of energy need, operating conditions, energy cost and energy supply variability. Three plants configuration; simple gas turbine (SGT), retrofitted combined cycle (RCC) and Built-in combined cycle (BCC) was analysed based on these economic performance indicators. The three configurations show a positive NPV, PBP and IRR, with the BCC showing the optimum return on investment. Although the RCC show minimum initial cost on investment compare to BCC, the BCC demonstrates greater overall return with an NPV of $30,755,454.18, IRR of 17.1% and PBP of 6.3years for the period of 20years. The analysis shows cash flow of 34.1% and 52.6% for the RCC and BCC respectively. The result also showed that the plant performs better at a lower ambient temperature and higher relative humidity with a higher return on investment. This research provides great insight into the thermo-economic analysis, and benefits of combined cycle power plant and will aid energy system investors on the choice of the power plant for power generation in the Niger Delta.


Author(s):  
Stephan Heide ◽  
Uwe Gampe ◽  
Ulrich Orth ◽  
Markus Beukenberg ◽  
Bernd Gericke ◽  
...  

Solar hybrid power plants are characterized by a combination of heat input both of high temperature solar heat and heat from combustion of gaseous or liquid fuel which enables to supply the electricity market according to its requirements and to utilize the limited and high grade natural resources economically. The SHCC® power plant concept integrates the high temperature solar heat into the gas turbine process and in addition — depending on the scheme of the process cycle — downstream into the steam cycle. The feed-in of solar heat into the gas turbine is carried out between compressor outlet and combustor inlet either by direct solar thermal heating of the pressurized air inside the receivers of the solar tower or by indirectly heating via interconnection of a heat transfer fluid. Thus, high shares of solar heat input referring to the total heat input of more than 60% in design point can be achieved. Besides low consumption of fossil fuels and high efficiency, the SHCC® concept is aimed for a permanent availability of the power plant capacity due to the possible substitution of solar heat by combustion heat during periods without sufficient solar irradiation. In consequence, no additional standby capacity is necessary. SHCC® can be conducted with today’s power plant and solar technology. One of the possible variants has already been demonstrated in the test field PSA in Spain using a small capacity gas turbine with location in the head of the solar tower for direct heating of the combustion air. However, the authors present and analyze also alternative concepts for power plants of higher capacity. Of course, the gas turbine needs a design which enables the external heating of the combustion air. Today only a few types of gas turbines are available for SHCC® demonstration. But these gas turbines were not designed for solar hybrid application at all. Thus, the autors present finally some reflections on gas turbine parameters and their consequences for SHCC® as basis for evaluation of potentials of SHCC®.


Author(s):  
S. Can Gülen ◽  
Raub W. Smith

A significant portion of the new electrical generating capacity installed in the past decade has employed heavy-duty gas turbines operating in a combined cycle configuration with a steam turbine bottoming cycle. In these power plants approximately one-third of the power is generated by the bottoming cycle. To ensure that the highest possible combined cycle efficiency is realized it is important to develop the combined cycle power plant as a system. Doing so requires a solid understanding of the efficiency entitlement of both, topping and bottoming, cycles separately and as a whole. This paper describes a simple but accurate method to estimate the Rankine bottoming cycle power output directly from the gas turbine exhaust exergy, utilizing the second law of thermodynamics. The classical first law approach, i.e., the heat and mass balance method, requires lengthy calculations and complex computer-based modeling tools to evaluate Rankine bottoming cycle performance. In this paper, a rigorous application of the fundamental thermodynamic principles embodied by the second law to the major cycle components clearly demonstrates that the Rankine cycle performance can be accurately represented by several key parameters. The power of the second law approach lies in its ability to highlight the theoretical entitlement and state-of-the-art design performances simultaneously via simple fundamental relationships. By considering economically and technologically feasible upper limits for the key parameters, the maximum achievable bottoming cycle power output is readily calculable for any given gas turbine from its exhaust exergy.


Author(s):  
Hsiao-Wei D. Chiang ◽  
Pai-Yi Wang ◽  
Hsin-Lung Li

With increasing demand for power and with shortages envisioned especially during the peak load times during the summer, there is a need to boost gas turbine power. In Taiwan, most of gas turbines operate with combined cycle for base load. Only a small portion of gas turbines operates with simple cycle for peak load. To prevent the electric shortage due to derating of power plants in hot days, the power augmentation strategies for combined cycles need to be studied in advance. As a solution, our objective is to add an overspray inlet fogging system into an existing gas turbine-based combined cycle power plant (CCPP) to study the effects. Simulation runs were made for adding an overspray inlet fogging system to the CCPP under various ambient conditions. The overspray percentage effects on the CCPP thermodynamic performance are also included in this paper. Results demonstrated that the CCPP net power augmentation depends on the percentage of overspray under site average ambient conditions. This paper also included CCPP performance parametric studies in order to propose overspray inlet fogging guidelines for combined cycle power augmentation.


Author(s):  
P. Shukla ◽  
M. Izadi ◽  
P. Marzocca ◽  
D. K. Aidun

The objective of this paper is to evaluate methods to increase the efficiency of a gas turbine power plant. Advanced intercooled gas turbine power plants are quite efficient, efficiency reaching about 47%. The efficiency could be further increased by recovering wasted heat. The system under consideration includes an intercooled gas turbine. The heat is being wasted in the intercooler and a temperature drop happens at the exhaust. For the current system it will be shown that combining the gas cycle with steam cycle and removing the intercooler will increase the efficiency of the combined cycle power plant up to 60%. In combined cycles the efficiency depends greatly on the exhaust temperature of the gas turbine and the higher gas temperature leads to the higher efficiency of the steam cycle. The analysis shows that the latest gas turbines with the intercooler can be employed more efficiently in a combined cycle power application if the intercooler is removed from the system.