Menentukan Desain Struktur Atas Gedung Fajar Biru Trenggalek Berdasarkan SNI (Standart Nasional Indonesia)

2021 ◽  
Vol 4 (2) ◽  
pp. 56
Author(s):  
Alfin Dino Saputra ◽  
Edy Gardjito ◽  
Sigit Winarto ◽  
Muhammad Heri Nastotok ◽  
Faiz Muhammad Azhari

A multi-storey reinforced concrete building is very prone to collapse. Therefore, proper structural planning is needed in order to qualify the strength and security of the structure. Fajar Biru Building is a building that will be built in Karangsuko village of Trenggalek Regency, East Java. The building functioned as a cost with a building area of 340 m2, and has a total of 4 floors. The method used is the SRPMM (Medium Moment Musician Frame System) method which refers to SNI 1726:2012, and SNI 2847:2013. Planning includes the calculation of beams, floor plates, and columns. From the results of the calculations that have been done. on the floor plate structure with a plate thickness of 120 mm, Ø12 tree bones are used with a distance of 100 mm for pedestals and 150 mm for field areas. On the looping of B1 beams with dimensions of 300x350 mm used 6-D16 tree bones for focus and 4-D16 for field areas with Ø10-70 mm for focus and Ø10-140 mm for field areas. For the repeating of Column K1 with dimensions of 300x600 mm used 10-D16 principal bones with a Ø10-70 mm dimension. So that from these results can be used as a reference in the implementation of the construction of the blue dawn building.

2019 ◽  
Vol 24 (2) ◽  
pp. 176
Author(s):  
Ni Kadek Astariani ◽  
I Gusti Made Sudika

The Structure of Reinforced concrete building using kalsi floor plate is one alternative for reduced the weight of the building structure. The floor plate usually used conventional concrete, can be replaced with kalsi floor 20. The aim of the research is to analysis of the behavior of reinforced concrete building using conventional concrete slabs and kalsi floor 20. The building structure as the model in this research is the building structure of four floors and was designed to follow the rules of SNI 2847: 2013. Evaluation of seismic behavior in accordance with the SNI 1726: 2012 was conducted out by applying pushover analysis using SAP 2000 software. The analysis results showed that drift ratio of plates floor structure models smaller than the kalsi floor plate structure. The pushover analysis results show the level of performance of all structural models according to FEMA-356 / ATC-40 able to provide nonlinear behavior which is indicated by the initial phase of the majority of plastic joints on beam elements and beam sway mechanism. The performance level of the structure with conventional concrete slab includes at immediate occupancy level, while the performance level of the structure with with kalsi floor plate includes at life safety level.


2017 ◽  
Author(s):  
Chee Ghuan Tan ◽  
Wei Ting Chia ◽  
Taksiah A. Majid ◽  
Fadzli Mohamed Nazri ◽  
Mohd Irwan Adiyanto

2021 ◽  
Vol 10 (2) ◽  
Author(s):  
Thasbih Al Fajri ◽  
Rafki Imani ◽  
Zakpar Siregar

The office building of the food security office of West Sumatra Province is a multi-storey building with reinforced concrete structures built in earthquake-prone areas that have the potential for large-scale earthquakes such as the one that occurred in 2009. Based on USGS data, from December 2004 to October 2009 There have been 10 earthquakes measuring more than 5 on the Richter scale that rocked Indonesia and resulted in damage to buildings, both minor damage to heavy damage and evencollapsing. The big earthquake that occurred on September 30, 2009 in Padang City, West Sumatra, was measuring 7.6 on the Richter scale. In this study, evaluated the seismic capacity of a reinforced concrete building 4 (four) floors built in earthquake-prone areas in the city of Padang. The seismic capacity of the building is evaluated based on the standard published by Japan, namely The Standard for Seismic Evaluation of Existin Reinforced Concrete Building, 2001. In this evaluation, it only looks at the structural elements of the column on the first floor. Seismic capacity is expressed in terms of the lateral strength index and the ductility index of the building. The results of the evaluation of seismic capacity obtained the total strength index value of the building is 0.707. The seismic capacity of this building can be shown to be adequate or strongin earthquake-prone areas compared to the seismic capacity of reinforced concrete buildings that survived the massive earthquake of 7.6 on the Richter Scale in West Sumatra in September 2009. From the evaluation results on this building which is located in an area including the prone to strong earthquakes can be stated to be able to behave ductile and able to withstand an earthquake or not experience sudden collapse


2019 ◽  
Vol 8 (4) ◽  
pp. 3633-3637

Precast concrete structures are widely used in construction. It consists of prefabricated elements casted in industry and connected to each other to form a homogeneous structure. Connections function is to transfer moments and axial forces. Many engineers assume precast connection as pinned, but in reality, they are semi-rigid connections that transfer forces to other members. Lack of design and detailing of connection leads to improper behaviour of the structure, which then leads to the collapse of the building. Past earthquake studies show that many precast buildings performed poorly, and the main reasons were connections. This paper mainly focuses on understanding the seismic behaviour of mid-rise i.e seven-storey precast reinforced concrete buildings with various beam-column joints i.e rigid, semi-rigid, pinned and column-base supports i.e, fixed and hinged supports. Building is modelled and analyzed using ETABS v17 software. Rotational stiffness of precast billet connection is adopted for modelling of semi-rigid beam-column connections. Response spectrum and modal analysis are carried out. Results of displacements, storey drift, storey shear, storey stiffness, base shear, time periods and first mode shapes of models are discussed. It is observed, precast reinforced concrete building models with semi rigid connection performs better than building models with pinned connections and building models with fixed supports reduces the structural response to a great extent.


Sign in / Sign up

Export Citation Format

Share Document