Design and characterization of a laminar flow-through dissolution apparatus: Comparison of hydrodynamic conditions to those of common dissolution techniques

2010 ◽  
Vol 16 (1) ◽  
pp. 75-87 ◽  
Author(s):  
Kristyn Greco ◽  
Theodore L. Bergman ◽  
Robin Bogner
Author(s):  
Seyed Ali Mousavi Shaegh ◽  
Nam-Trung Nguyen ◽  
Siew Hwa Chan

This paper reports the fabrication and characterization of a new concept of flow-through anode for membraneless laminar flow fuel cell (LFFC). To establish a reference case, a fuel cell with flow over and planar anode was fabricated as well. Experimental results indicated that maximum power density was improved from 17 mW/cm2 in planar design to 23 mW/cm2 using the flow-through design. The higher power density of flow-through design is an indicative of higher fuel utilization in the porous anode. Images of the flow obtained experimentally showed that mixing was reduced at the liquid-liquid interface in the channel with flow-through anode leading to increased fuel concentration over anode.


Author(s):  
Jose Raul Medina ◽  
Erik Aguilar ◽  
Marcela Hurtado

Objective: To characterize the dissolution behaviour of carbamazepine generic suspensions using the USP Dissolution Apparatus 2 and the flow-through cell method with simulated gastrointestinal fluids as dissolution media.Methods: Tegretol® suspension and two generic formulations were tested. Dissolution studies were performed using the USP Apparatus 2 (75 rpm and 900 ml of dissolution medium) and the flow-through cell method (laminar flow at 16 ml/min). Simulated gastric fluid (SGF) (with and without pepsin) and simulated intestinal fluid (SIF) (without pancreatin) at 37.0±0.5 °C, was used as dissolution media. The quantity of dissolved carbamazepine was determined at 5 min intervals until reaching 60 min, at 285 nm. Percentage dissolved at 60 min, mean dissolution time, dissolution efficiency values (model-independent parameters), as well as t50% and t63.2% were calculated (model-dependent parameters). Values for all parameters were compared between the reference and generic formulations using one-way analysis of variance (ANOVA) following a Dunnett’s multiple comparison test. Dissolution data were also fitted to different fit models.Results: Since the first sampling time, the reference product had reached 100% of drug dissolved, which was determined using USP Apparatus 2. Nevertheless, significant differences in the three model-independent parameters of generic products were found (*P<0.05). Dissolution data obtained with the paddle apparatus were fitted to different kinetic equations; however, using the flow-through cell method and SIF without pancreatin, the three drug products were fitted to the same kinetic model (Gompertz). With ANOVA-based comparisons and the flow-through cell method, significant differences were found in dissolution data of generic product A versus reference at all sampling times (*P<0.05). The flow-through cell method and SGF with pepsin were the best options to discriminate among dissolution profiles.Conclusion: The flow-through cell method seems to be an adequate dissolution apparatus to characterize in vitrodissolution performance of Class II drugs manufactured as suspensions. For carbamazepine suspensions, SGF and laminar flow at 16 ml/min were the most appropriate conditions to discriminate among generic formulations. Given the physicochemical characteristics of carbamazepine and the environment in which the drug products were tested, these differences could be of clinical relevance. 


2021 ◽  
Vol 8 (3) ◽  
pp. 41
Author(s):  
Fardin Khalili ◽  
Peshala T. Gamage ◽  
Amirtahà Taebi ◽  
Mark E. Johnson ◽  
Randal B. Roberts ◽  
...  

Treatments of atherosclerosis depend on the severity of the disease at the diagnosis time. Non-invasive diagnosis techniques, capable of detecting stenosis at early stages, are essential to reduce associated costs and mortality rates. We used computational fluid dynamics and acoustics analysis to extensively investigate the sound sources arising from high-turbulent fluctuating flow through stenosis. The frequency spectral analysis and proper orthogonal decomposition unveiled the frequency contents of the fluctuations for different severities and decomposed the flow into several frequency bandwidths. Results showed that high-intensity turbulent pressure fluctuations appeared inside the stenosis for severities above 70%, concentrated at plaque surface, and immediately in the post-stenotic region. Analysis of these fluctuations with the progression of the stenosis indicated that (a) there was a distinct break frequency for each severity level, ranging from 40 to 230 Hz, (b) acoustic spatial-frequency maps demonstrated the variation of the frequency content with respect to the distance from the stenosis, and (c) high-energy, high-frequency fluctuations existed inside the stenosis only for severe cases. This information can be essential for predicting the severity level of progressive stenosis, comprehending the nature of the sound sources, and determining the location of the stenosis with respect to the point of measurements.


2006 ◽  
Vol 36 (9) ◽  
pp. 1575-1582 ◽  
Author(s):  
Vicente Navarro ◽  
Ángel Yustres ◽  
Luís Cea ◽  
Miguel Candel ◽  
Ricardo Juncosa ◽  
...  

2009 ◽  
Vol 64 (19) ◽  
pp. 4186-4195 ◽  
Author(s):  
Odile Gerbaux ◽  
Thibaut Vercueil ◽  
Alain Memponteil ◽  
Bruno Bador