EXPERIMENTAL STUDY ON JOINT OF SEISMIC RETROFITTING BRACE FOR STEEL STRUCTURE USING SHEAR-KEY PLATE ADHERED TO CONCRETE SLAB

Author(s):  
Yasushi ICHIKAWA ◽  
Tsugutomo OKAYASU ◽  
Hiroshi NAKAMURA ◽  
Satoshi YAMADA ◽  
Akira WADA
2006 ◽  
Vol 71 (610) ◽  
pp. 177-184
Author(s):  
Yasushi ICHIKAWA ◽  
Kazuaki SUZUKI ◽  
Hiroaki HARADA ◽  
Satoshi YAMADA ◽  
Akira WADA

Structures ◽  
2021 ◽  
Vol 34 ◽  
pp. 507-522
Author(s):  
Yang Dong ◽  
Lianguang Jia ◽  
Feng Xu ◽  
Xianchao Li

2011 ◽  
Vol 243-249 ◽  
pp. 1435-1438 ◽  
Author(s):  
Ming Chen ◽  
Yang Sun ◽  
Bing Qian Pi

The double C steel section is made of two C steels with gusset plate through bolts. A ridge joint of double C steel is studied through experiment under cyclic loading in this paper. Through the four specimens with different gusset-plate’s thickness and bolt spacing, we analyze the effect of the gusset-plate’s thickness and bolt spacing on stiffness, ductility and energy performance. At last we recommend the suitable gusset-plate’s thickness. The results can give a reference to the engineering application of cold-formed steel structure.


2011 ◽  
Vol 17 (35) ◽  
pp. 31-35
Author(s):  
Shigemitsu HATANAKA ◽  
Naoki MISHIMA ◽  
Hiroshi WATOH ◽  
Akio MURAMATSU ◽  
Takeshi YAMAGUCHI ◽  
...  

2013 ◽  
Vol 405-408 ◽  
pp. 1815-1819
Author(s):  
Wen Sheng Yu ◽  
Zhu Long Li ◽  
Xiao Ru Xie ◽  
Li Yuan Guo

To analyze the earth pressure of corrugated steel culvert under high fill embankment, a field test was taken and the change law was got with the filling height increasing, the force state when geotechnical grilles were laid on the top of corrugated steel culvert was compared to that of reinforced concrete slab culvert. Results show that the pressure on the top of corrugated steel culvert is smaller than that on the external in same level when test points are near to culvert, the values of test points above and below geotechnical grilles are close, and the pressure of corrugated steel culvert is smaller than that of reinforced concrete slab culvert when filling height is above 7.3 m. So analysis indicates corrugated steel culvert spreads the upper load better, the geotechnical grille can reduce the pressure effectively through earth pressure redistribution, and the mechanical property of corrugated steel culvert is better than reinforced concrete slab culvert under high fill embankment.


Abstract. A steel structure is naturally lighter than a comparable concrete construction because of the higher strength and firmness of steel. Nowadays, the growth of steel structures in India is enormous. There are so many advantages in adopting the steel as structural members. Almost all high-rise buildings, warehouses & go-downs are steel structures and even some of the commercial buildings are made of steel. Tension members are the elements that are subjected to direct axial load which tends in the elongation of the structural members. Even today bolted connections play a major role in the connection of hot rolled structural steel members. In this experimental study the behavior of tension members (TM) such as plates, angles & channels have been studied under axial tensile force. There is strong relation between pitch and gauge (with in the specified limit as per IS 800:2007) in determining the rupture failure plane. In this study we intensively tested the behaviour of TM for different fasteners pattern by changing the pitch, gauge, end & edge distance and by adopting the different patterns or arrangements of bolted connection in it.


2017 ◽  
Vol 35 (2) ◽  
pp. 169s-172s ◽  
Author(s):  
Seiichiro Tsutsumi ◽  
Ryota Nagao ◽  
Riccardo Fincato ◽  
Toshiyuki Ishikawa ◽  
Risa Matsumoto

Sign in / Sign up

Export Citation Format

Share Document