Analisis Perbandingan Jenis Material Penukar Kalor Plat Datar Aliran Silang Untuk Proses Pengeringan Kayu

2021 ◽  
Vol 9 (1) ◽  
pp. 60-71
Author(s):  
Abeth Novria Sonjaya ◽  
Marhaenanto Marhaenanto ◽  
Mokhamad Eka Faiq ◽  
La Ode M Firman

The processed wood industry urgently needs a dryer to improve the quality of its production. One of the important components in a dryer is a heat exchanger. To support a durable heat transfer process, a superior material is needed. The aim of the study was to analyze the effectiveness of the application of cross-flow flat plate heat exchangers to be used in wood dryers and compare the materials used and simulate heat transfer on cross-flow flat plate heat exchangers using Computational Fluid Dynamic simulations. The results showed that there was a variation in the temperature out of dry air and gas on the flat plate heat exchanger and copper material had a better heat delivery by reaching the temperature out of dry air and gas on the flat plate type heat exchanger of successive cross flow and.   overall heat transfer coefficient value and the effectiveness value of the heat exchanger of the heat transfer characteristics that occur with the cross-flow flat plate type heat exchanger in copper material of 251.74725 W/K and 0.25.

Author(s):  
M. A. Arie ◽  
A. H. Shooshtari ◽  
S. V. Dessiatoun ◽  
M. M. Ohadi ◽  
E. Al Hajri

This paper describes a multi-objective optimization of single-phase, laminar flow inside a single element of a manifold microchannel flat plate heat exchanger. Approximation assisted optimization was used for the optimization process. The process uses metamodeling in conjunction with Computational Fluid Dynamic (CFD) simulation as a method to minimize the number of function evaluations and thereby obtain substantial reductions in computational time. Two optimization objectives were considered: a) maximizing heat density rate per temperature difference Q/(VΔT) and minimizing pumping power density (P/V), and b) maximizing base heat transfer coefficient (h) and minimizing pumping power per base area (P/Abase). Water and air were used as working fluids to compare the optimum solutions of the two fluids with very distinctive thermo-physical properties. The study shows that both optimization objectives result in similar optimum points. The behaviors of the optimum solutions for water and air are also discussed in detail. Additionally, as a case study using the optimization results, it was demonstrated that for an array of microchannels with volume as low as 4,250 mm3 on one side, pumping power of 138 W and heat transfer rate of 56.7 kW can be achieved using water.


2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Faraz Afshari ◽  
Azim Doğuş Tuncer ◽  
Adnan Sözen ◽  
Halil Ibrahim Variyenli ◽  
Ataollah Khanlari ◽  
...  

Purpose Using suspended nanoparticles in the base fluid is known as one of the most efficient ways for heat transfer augmentation and improving the thermal efficiency of various heat exchangers. Different types of nanofluids are available and used in different applications. The main purpose of this study is to investigate the effects of using hybrid nanofluid and number of plates on the performance of plate heat exchanger. In this study, TiO2/water single nanofluid and TiO2-Al2O3/water hybrid nanofluid with 1% particle weight ratio have been used to prepare hybrid nanofluid to use in plate type heat exchangers with three various number of plates including 8, 12 and 16. Design/methodology/approach The experiments have been conducted with the aim of examining the impact of plates number and used nanofluids on heat transfer enhancement. The performance tests have been done at 40°C, 45°C, 50°C and 55°C set outlet temperatures and in five various Reynolds numbers between 1,600 and 3,800. Also, numerical simulation has been applied to verify the heat and flow behavior inside the heat exchangers. Findings The results indicated that using both nanofluids raised the thermal performance of all tested exchangers which have a various number of plates. While the major outcomes of this study showed that TiO2-Al2O3/water hybrid nanofluid has priority when compared to TiO2/water single type nanofluid. Utilization of TiO2-Al2O3/water nanofluid led to obtaining an average improvement of 7.5%, 9.6% and 12.3% in heat transfer of heat exchangers with 8, 12 and 16 plates, respectively. Originality/value In the present work, experimental and numerical analyzes have been conducted to investigate the influence of using TiO2-Al2O3/water hybrid nanofluid in various plate heat exchangers. The attained findings showed successful utilization of TiO2-Al2O3/water nanofluid. Based on the obtained results increasing the number of plates in the heat exchanger caused to obtain more increment by using both types of nanofluids.


2010 ◽  
Vol 132 (11) ◽  
Author(s):  
M. J. White ◽  
G. F. Nellis ◽  
S. A. Klein ◽  
W. Zhu ◽  
Y. Gianchandani

Cryogenic and high-temperature systems often require compact heat exchangers with a high resistance to axial conduction in order to control the heat transfer induced by axial temperature differences. One attractive design for such applications is a perforated plate heat exchanger that utilizes high conductivity perforated plates to provide the stream-to-stream heat transfer and low conductivity spacers to prevent axial conduction between the perforated plates. This paper presents a numerical model of a perforated plate heat exchanger that accounts for axial conduction, external parasitic heat loads, variable fluid and material properties, and conduction to and from the ends of the heat exchanger. The numerical model is validated by experimentally testing several perforated plate heat exchangers that are fabricated using microelectromechanical systems based manufacturing methods. This type of heat exchanger was investigated for potential use in a cryosurgical probe. One of these heat exchangers included perforated plates with integrated platinum resistance thermometers. These plates provided in situ measurements of the internal temperature distribution in addition to the temperature, pressure, and flow rate measured at the inlet and exit ports of the device. The platinum wires were deposited between the fluid passages on the perforated plate and are used to measure the temperature at the interface between the wall material and the flowing fluid. The experimental testing demonstrates the ability of the numerical model to accurately predict both the overall performance and the internal temperature distribution of perforated plate heat exchangers over a range of geometry and operating conditions. The parameters that were varied include the axial length, temperature range, mass flow rate, and working fluid.


1999 ◽  
Vol 121 (1) ◽  
pp. 110-117 ◽  
Author(s):  
A. Muley ◽  
R. M. Manglik

Experimental heat transfer and isothermal pressure drop data for single-phase water flows in a plate heat exchanger (PHE) with chevron plates are presented. In a single-pass U-type counterflow PHE, three different chevron plate arrangements are considered: two symmetric plate arrangements with β = 30 deg/30 deg and 60 deg/60 deg, and one mixed-plate arrangement with β = 30 deg/60 deg. For water (2 < Pr < 6) flow rates in the 600 < Re < 104 regime, data for Nu and f are presented. The results show significant effects of both the chevron angle β and surface area enlargement factor φ. As β increases, and compared to a flat-plate pack, up to two to five times higher Nu are obtained; the concomitant f, however, are 13 to 44 times higher. Increasing φ also has a similar, though smaller effect. Based on experimental data for Re a 7000 and 30 deg ≤ β ≤ 60 deg, predictive correlations of the form Nu = C1,(β) D1(φ) Rep1(β)Pr1/3(μ/μw)0.14 and f = C2(β) D2(φ) Rep2(β) are devised. Finally, at constant pumping power, and depending upon Re, β, and φ, the heat transfer is found to be enhanced by up to 2.8 times that in an equivalent flat-plate channel.


Volume 1 ◽  
2004 ◽  
Author(s):  
H. Shokouhmand ◽  
N. Khareghani

In this paper, transient response of plate heat exchangers under flow maldistribution and viscosity variations is discussed. This transient response is compared with the response achieved from uniform flow and constant viscosity through the exchanger. Flow maldistribution (unequal flow in channels) is calculated for U and Z types of plate heat exchangers. This flow maldistribution along with viscosity variations, during the growth of the temperature profile in each channel, affect the convective heat transfer coefficient in the transient period of heat transfer, and make it to be different from that of the other channels. These conditions make the transient response of a plate heat exchanger to have some deviations from the uniform flow and constant viscosity model response, which is discussed in this paper. The governing equations of heat transfer are solved using finite difference methods. Frequency response as well as step response of the heat exchanger is implemented as a time dependent initial conditions.


1993 ◽  
Vol 115 (3) ◽  
pp. 584-591 ◽  
Author(s):  
B. Bansal ◽  
H. Mu¨ller-Steinhagen

Crystallization fouling of calcium sulfate was investigated in a plate and frame heat exchanger. The effects of flow velocity, wall temperature, and CaSO4, concentration on the fouling rates have been investigated and the distribution of scale along the heat transfer surface has been observed. The measured fouling curves are compared with predictions from a surface reaction controlled model.


2017 ◽  
Vol 71 (5) ◽  
pp. 439-449
Author(s):  
Nikola Zlatkovic ◽  
Divna Majstorovic ◽  
Mirjana Kijevcanin ◽  
Emila Zivkovic

Plate heat exchanger is a type of heat exchanger that uses corrugated metal plates to transfer heat between two fluids. The plate corrugations are designed to achieve turbulence across the entire heat transfer area thus producing the highest possible heat transfer coefficients while allowing close temperature approaches. Subsequently, this leads to a smaller heat transfer area, smaller units and in some cases, fewer heat exchangers. In this work, an application for thermal and hydraulic computations of plate heat exchangers had been developed using Sharp Develop, an open source programming platform. During the development process, several literature methods and correlations for calculation of heat transfer coefficient and pressure drop in a plate heat exchanger have been tested and the selected four methods: Martin, VDI, Kumar and Coulson and Richardson have been incorporated into the software. The structure of the software is visually presented through several windows: a window for inserting input data, windows for showing the results of computation by each of the methods, a window for showing comparative analysis of the most important computation results obtained by all of the used methods and a help window for demonstrating the working principle of plate heat exchanger.


Author(s):  
Foluso Ladeinde ◽  
Kehinde Alabi ◽  
Wenhai Li

Manifold-microchannel combinations used on heat transfer surfaces have shown the potential for superior heat transfer performance to pressure drop ratio when compared to chevron type corrugations for plate heat exchangers (PHE) [1–4]. However, compared with heat transfer enhancements such as intermating troughs and Chevron corrugations, manifold-microchannels (MM) have several times more variables that influence the heat transfer and pressure drop characteristics, including microchannel width, depth, passes, manifold depth, width, and manifold fin thickness. Previous work has reported on the effects of some of the variables, and provides some models for their effects on thermal and hydraulic performance. The current paper presents a genetic algorithm (GA)-based procedure to analyze the implicit effects of some of the manifold-microchannel variables, and compare the performance of manifold-microchannel plate heat exchangers to those using standard Chevron corrugations. The objective of the present work is to evaluate the performance of manifold-microchannel heat transfer enhancements and demonstrate the potential for using GA-based procedure to optimize the heat exchanger. This paper also presents the modifications of the standard GA algorithm when applied to the optimization of MM. The resulting GA procedure is particularly well suited to PHEs for several reasons, including the fact that it does not require continuous variables or functional dependence on the design variables. In addition, the computational effort required for the GA technique in our implementation scales linearly, with a scaling coefficient that is significantly less than one, making it economical to analyze PHEs with several variables with degrees of freedom (DOF) with respect to the fitness function. The results of optimizing a manifold-microchannel plate heat exchanger are presented, and the exchanger’s performance is compared to more conventional PHE of the same volume utilizing chevron corrugations. Finally, results from the empirical procedure presented in this paper for a manifold-microchannel are compared with experimental measurements in Andhare [5].


Sign in / Sign up

Export Citation Format

Share Document