AbstractLegionella pneumophilacontinues to play a role in both community- and nosocomially-acquired pneumonia. We investigated the ability ofL pneumophilato adhere to various types of materials such as those found in the hospital air-cooling and potable water distribution systems. Through the use of a unique sampling apparatus, we were able to regularly acquire planktonic and sessile samples and determine the numbers of bacteria present in both populations, in vitro and in situ.Portions of these apparatuses could be aseptically removed for examination by scanning electron microscopy, or for the determination of the number of viable adherentL pneumophila.The number of bacteria present in each sample was determined by direct plate count, with presumptiveL pneumophilacolonies being positively identified by direct fluorescent antibody staining techniques.The results demonstrated that not only are legionellae capable of colonizing various metallic and nonmetallic surfaces but that they are preferentially found on surfaces. Surface-adherent bacteria may play a profound role as a reservoir of these potential pathogens in aquatic environments. Furthermore, these results suggest that any comprehensive legionella monitoring program must include not only water samples but also an examination of the adherent populations.


1987 ◽  
Vol 8 (9) ◽  
pp. 357-363 ◽  
Author(s):  
Richard M. Vickers ◽  
Victor L. Yu ◽  
S. Sue Hanna ◽  
Paul Muraca ◽  
Warren Diven ◽  
...  

AbstractWe conducted a prospective environmental study for Legionella pneumophila in 15 hospitals in Pennsylvania. Hot water tanks, cold water sites, faucets, and show-erheads were surveyed four times over a one-year period. Sixty percent (9/15) of hospitals surveyed were contaminated with L pneumophila. Although contamination could not be linked to a specific municipal water supplier, most of the contaminated supplies came from rivers. Parameters found to be significantly associated with contamination included elevated hot water temperature, vertical configuration of the hot water tank, older tanks, and elevated calcium and magnesium concentrations of the water (P < 0.05). This study suggests that L pneumophila contamination could be predicted based on design of the distribution system, as well as physicochemical characteristics of the water.


Author(s):  
Luna Girolamini ◽  
Silvano Salaris ◽  
Jessica Lizzadro ◽  
Marta Mazzotta ◽  
Maria Rosaria Pascale ◽  
...  

In this study, we aimed to associate the molecular typing of Legionella isolates with a culture technique during routine Legionella hospital environmental surveillance in hot water distribution systems (HWDSs) to develop a risk map able to be used to prevent nosocomial infections and formulate appropriate preventive measures. Hot water samples were cultured according to ISO 11731:2017. The isolates were serotyped using an agglutination test and genotyped by sequence-based typing (SBT) for Legionella pneumophila or macrophage infectivity potentiator (mip) gene sequencing for non-pneumophila Legionella species. The isolates’ relationship was phylogenetically analyzed. The Legionella distribution and level of contamination were studied in relation to temperature and disinfectant residues. The culture technique detected 62.21% of Legionella positive samples, characterized by L. pneumophila serogroup 1, Legionella non-pneumophila, or both simultaneously. The SBT assigned two sequence types (STs): ST1, the most prevalent in Italy, and ST104, which had never been isolated before. The mip gene sequencing detected L. anisa and L. rubrilucens. The phylogenetic analysis showed distinct clusters for each species. The distribution of Legionella isolates showed significant differences between buildings, with a negative correlation between the measured level of contamination, disinfectant, and temperature. The Legionella molecular approach introduced in HWDSs environmental surveillance permits (i) a risk map to be outlined that can help formulate appropriate disinfection strategies and (ii) rapid epidemiological investigations to quickly identify the source of Legionella infections.


Pathogens ◽  
2020 ◽  
Vol 9 (4) ◽  
pp. 286 ◽  
Author(s):  
Muhammad Atif Nisar ◽  
Kirstin E. Ross ◽  
Melissa H. Brown ◽  
Richard Bentham ◽  
Harriet Whiley

Legionella pneumophila is an opportunistic waterborne pathogen of public health concern. It is the causative agent of Legionnaires’ disease (LD) and Pontiac fever and is ubiquitous in manufactured water systems, where protozoan hosts and complex microbial communities provide protection from disinfection procedures. This review collates the literature describing interactions between L. pneumophila and protozoan hosts in hospital and municipal potable water distribution systems. The effectiveness of currently available water disinfection protocols to control L. pneumophila and its protozoan hosts is explored. The studies identified in this systematic literature review demonstrated the failure of common disinfection procedures to achieve long term elimination of L. pneumophila and protozoan hosts from potable water. It has been demonstrated that protozoan hosts facilitate the intracellular replication and packaging of viable L. pneumophila in infectious vesicles; whereas, cyst-forming protozoans provide protection from prolonged environmental stress. Disinfection procedures and protozoan hosts also facilitate biogenesis of viable but non-culturable (VBNC) L. pneumophila which have been shown to be highly resistant to many water disinfection protocols. In conclusion, a better understanding of L. pneumophila-protozoan interactions and the structure of complex microbial biofilms is required for the improved management of L. pneumophila and the prevention of LD.


2019 ◽  
Vol 163 ◽  
pp. 7-16
Author(s):  
Motasem N. Saidan ◽  
Ahlam I. Abdalla ◽  
Nivin Al Alami ◽  
Hanan Al-Naimat

2014 ◽  
Vol 35 (3) ◽  
pp. 293-299 ◽  
Author(s):  
Beatrice Casini ◽  
Andrea Buzzigoli ◽  
Maria Luisa Cristina ◽  
Anna Maria Spagnolo ◽  
Pietro Del Giudice ◽  
...  

Objective and Design.Legionellacontrol still remains a critical issue in healthcare settings where the preferred approach to health risk assessment and management is to develop a water safety plan. We report the experience of a university hospital, where a water safety plan has been applied since 2002, and the results obtained with the application of different methods for disinfecting hot water distribution systems in order to provide guidance for the management of water risk.Interventions.The disinfection procedures included continuous chlorination with chlorine dioxide (0.4–0.6 mg/L in recirculation loops) reinforced by endpoint filtration in critical areas and a water treatment based on monochloramine (2-3 mg/L). Real-time polymerase chain reaction and a new immunoseparation and adenosine triphosphate bioluminescence analysis were applied in environmental monitoring.Results.After 9 years, the integrated disinfection-filtration strategy significantly reduced positive sites by 55% and the mean count by 78% (P< .05); however, the high costs and the occurrence of a chlorine-tolerant clone belonging toLegionella pneumophilaST269 prompted us to test a new disinfectant. The shift to monochloramine allowed us to eliminate planktonicLegionellaand did not require additional endpoint filtration; however, nontuberculous mycobacteria were isolated more frequently as long as the monochloramine concentration was 2 mg/L; their cultivability was never regained by increasing the concentration up to 3 mg/L.Conclusions.Any disinfection method needs to be adjusted/fine-tuned in individual hospitals in order to maintain satisfactory results over time, and only a locally adapted evidence-based approach allows assessment of the efficacy and disadvantages of the control measures.