scholarly journals Comprehensive biomechanical analysis of three reconstruction techniques following total sacrectomy: an in vitro human cadaveric model

2017 ◽  
Vol 27 (5) ◽  
pp. 570-577 ◽  
Author(s):  
Mohamed Macki ◽  
Rafael De la Garza-Ramos ◽  
Ashley A. Murgatroyd ◽  
Kenneth P. Mullinix ◽  
Xiaolei Sun ◽  
...  

OBJECTIVEAggressive sacral tumors often require en bloc resection and lumbopelvic reconstruction. Instrumentation failure and pseudarthrosis remain a clinical concern to be addressed. The objective in this study was to compare the biomechanical stability of 3 distinct techniques for sacral reconstruction in vitro.METHODSIn a human cadaveric model study, 8 intact human lumbopelvic specimens (L2–pelvis) were tested for flexion-extension range of motion (ROM), lateral bending, and axial rotation with a custom-designed 6-df spine simulator as well as axial compression stiffness with the MTS 858 Bionix Test System. Biomechanical testing followed this sequence: 1) intact spine; 2) sacrectomy (no testing); 3) Model 1 (L3–5 transpedicular instrumentation plus spinal rods anchored to iliac screws); 4) Model 2 (addition of transiliac rod); and 5) Model 3 (removal of transiliac rod; addition of 2 spinal rods and 2 S-2 screws). Range of motion was measured at L4–5, L5–S1/cross-link, L5–right ilium, and L5–left ilium.RESULTSFlexion-extension ROM of the intact specimen at L4–5 (6.34° ± 2.57°) was significantly greater than in Model 1 (1.54° ± 0.94°), Model 2 (1.51° ± 1.01°), and Model 3 (0.72° ± 0.62°) (p < 0.001). Flexion-extension at both the L5–right ilium (2.95° ± 1.27°) and the L5–left ilium (2.87° ± 1.40°) for Model 3 was significantly less than the other 3 cohorts at the same level (p = 0.005 and p = 0.012, respectively). Compared with the intact condition, all 3 reconstruction groups statistically significantly decreased lateral bending ROM at all measured points. Axial rotation ROM at L4–5 for Model 1 (2.01° ± 1.39°), Model 2 (2.00° ± 1.52°), and Model 3 (1.15° ± 0.80°) was significantly lower than the intact condition (5.02° ± 2.90°) (p < 0.001). Moreover, axial rotation for the intact condition and Model 3 at L5–right ilium (2.64° ± 1.36° and 2.93° ± 1.68°, respectively) and L5–left ilium (2.58° ± 1.43° and 2.93° ± 1.71°, respectively) was significantly lower than for Model 1 and Model 2 at L5–right ilium (5.14° ± 2.48° and 4.95° ± 2.45°, respectively) (p = 0.036) and L5–left ilium (5.19° ± 2.34° and 4.99° ± 2.31°) (p = 0.022). Last, results of the axial compression testing at all measured points were not statistically different among reconstructions.CONCLUSIONSThe addition of a transverse bar in Model 2 offered no biomechanical advantage. Although the implementation of 4 iliac screws and 4 rods conferred a definitive kinematic advantage in Model 3, that model was associated with significantly restricted lumbopelvic ROM.

2019 ◽  
Vol 10 (8) ◽  
pp. 973-981
Author(s):  
Raymond J. Hah ◽  
Ram Alluri ◽  
Paul A. Anderson

Study Design: Biomechanics study. Objectives: To evaluate the biomechanical advantage of interfacet allograft spacers in an unstable single-level and 2-level anterior cervical discectomy and fusion (ACDF) pseudoarthrosis model. Methods: Nine single-level and 8 two-level ACDF constructs were tested. Range of motion in flexion-extension (FE), lateral bending (LB), and axial rotation (AR) at 1.5 N m were collected in 4 testing configurations: (1) intact spine, (2) ACDF with interbody graft and plate/screw, (3) ACDF with interbody graft and plate/loosened screws (loose condition), and (4) ACDF with interbody graft and plate/loosened screws supplemented with interfacet allograft spacers (rescue condition). Results: All fixation configurations resulted in statistically significant decreases in range of motion in all bending planes compared with the intact spine ( P < .05). One Level. Performing ACDF with interbody graft and plate on the intact spine reduced FE, LB, and AR 60.0%, 64.9%, and 72.9%, respectively. Loosening the ACDF screws decreased these reductions to 40.9%, 44.6%, and 52.1%. The addition of interfacet allograft spacers to the loose condition increased these reductions to 74.0%, 84.1%, and 82.1%. Two Level. Performing ACDF with interbody graft and plate on the intact spine reduced FE, LB, and AR 72.0%, 71.1%, and 71.2%, respectively. Loosening the ACDF screws decreased these reductions to 55.4%, 55.3%, and 51.3%. The addition of interfacet allograft spacers to the loose condition significantly increased these reductions to 82.6%, 91.2%, and 89.3% ( P < .05). Conclusions: Supplementation of a loose ACDF construct (pseudarthrosis model) with interfacet allograft spacers significantly increases stability and has potential applications in treating cervical pseudarthrosis.


Neurosurgery ◽  
2013 ◽  
Vol 73 (3) ◽  
pp. 517-527 ◽  
Author(s):  
Bruno C.R. Lazaro ◽  
Phillip M. Reyes ◽  
Anna G.U.S. Newcomb ◽  
Ali S. Yaqoobi ◽  
Leonardo B.C. Brasiliense ◽  
...  

Abstract BACKGROUND: Transitioning from rigid to flexible hardware at the distal rostral or caudal lumbar or lumbosacral level hypothetically maintains motion at the transition level and protects the transition level and intact adjacent levels from stresses caused by fusion. OBJECTIVE: To biomechanically compare transitional and rigid constructs with uninstrumented specimens in vitro. METHODS: Human cadaveric L2-S1 segments were tested (1) intact, (2) after L5-S1 rigid pedicle screw-rod fixation, (3) after L4-S1 rigid pedicle screw-rod fixation, and (4) after hybrid fixation rigidly spanning L5-S1 and dynamically spanning L4-L5. Pure moments (maximum 7.5 Nm) induced flexion, extension, lateral bending, and axial rotation while motion was recorded optoelectronically. Additionally, specimens were studied in flexion/extension with a 400-N compressive follower load. Strain gauges on laminae were used to extract facet loads. RESULTS: The range of motion at the transition segment (L4-L5) for the hybrid construct was significantly less than for the intact condition and significantly greater than for the rigid 2-level construct during lateral bending and axial rotation but not during flexion or extension. Sagittal axis of rotation at L4-L5 shifted significantly after rigid 2-level or hybrid fixation (P &lt; .003) but shifted significantly farther posterior and rostral with rigid fixation (P &lt; .02). Instrumentation altered L4-L5 facet load at more than the L3-L4 facet load. CONCLUSION: The effect of the dynamic rod segment on the kinematics of the transition level was less pronounced than that of a fully rigid construct in vitro with this particular rod system. This experimental model detected no biomechanical alterations at adjacent intact levels with hybrid or rigid systems.


2014 ◽  
Vol 20 (2) ◽  
pp. 209-219 ◽  
Author(s):  
Sabrina A. Gonzalez-Blohm ◽  
James J. Doulgeris ◽  
Kamran Aghayev ◽  
William E. Lee ◽  
Andrey Volkov ◽  
...  

Object In this paper the authors evaluate through in vitro biomechanical testing the performance of an interspinous fusion device as a stand-alone device, after lumbar decompression surgery, and as supplemental fixation to expandable cages in a posterior lumbar interbody fusion (PLIF) construct. Methods Nine L3–4 human cadaveric spines were biomechanically tested under the following conditions: 1) intact/control; 2) L3–4 left hemilaminotomy with partial discectomy (injury); 3) interspinous spacer (ISS); 4) bilateral pedicle screw system (BPSS); 5) bilateral hemilaminectomy, discectomy, and expandable posterior interbody cages with ISS (PLIF-ISS); and 6) PLIF-BPSS. Each test consisted of 100 N of axial preload with ± 7.5 Nm of torque in flexion-extension, right/left lateral bending, and right/left axial rotation. Significant changes in range of motion (ROM), neutral zone stiffness (NZS), elastic zone stiffness (EZS), and energy loss (EL) were explored among conditions using nonparametric Friedman test and Wilcoxon signed-rank comparisons (p ≤ 0.05). Results The injury increased ROM in flexion (p = 0.01), left bending (p = 0.03), and right/left rotation (p < 0.01) and also decreased NZS in flexion (p = 0.01) and extension (p < 0.01). Both the ISS and BPSS reduced flexion-extension ROM and increased flexion-extension stiffness (NZS and EZS) with respect to the injury and intact conditions (p < 0.05), but the ISS condition provided greater resistance than BPSS in extension for ROM, NZS, and EZS (p < 0.01). The BPSS increased the rigidity (ROM, NZS, and EZS) of the intact model in lateral bending and axial rotation (p ≤ 0.01), except in EZS for left rotation (p = 0.23, Friedman test). The incorporation of posterior cages marginally increased (p = 0.05) the EZS of the BPSS construct in flexion but these interbody devices provided significant stability to the ISS construct in lateral bending and axial rotation for ROM (p = 0.02), in lateral bending for NZS (p = 0.02), and in flexion/axial rotation for EZS (p ≤ 0.03); however, both PLIF constructs demonstrated equivalent ROM and stiffness (p ≥ 0.16), except in lateral bending where the PLIF-BPSS was more stable (p = 0.02). In terms of EL, the injury increased EL in flexion-extension (p = 0.02), the ISS increased EL for lateral bending and axial rotation (p ≤ 0.03), and the BPSS decreased EL in lateral bending (p = 0.02), with respect to the intact condition. The PLIF-ISS decreased lateral bending EL with respect to the ISS condition (p = 0.02), but not enough to be smaller or, at least, equivalent, to that of the PLIF-BPSS construct (p = 0.02). Conclusions The ISS may be a suitable device to provide immediate flexion-extension balance after a unilateral laminotomy, but the BPSS provides greater immediate stability in lateral bending and axial rotation motions. Both PLIF constructs performed equivalently in flexion-extension and axial rotation, but the PLIF-BPSS construct is more resistant to lateral bending motions. Further biomechanical and clinical evidence is required to strongly support the recommendation of a stand-alone interspinous fusion device or as supplemental fixation to expandable posterior interbody cages.


2019 ◽  
Vol 30 (3) ◽  
pp. 367-375 ◽  
Author(s):  
Bryan W. Cunningham ◽  
Paul D. Sponseller ◽  
Ashley A. Murgatroyd ◽  
Jun Kikkawa ◽  
P. Justin Tortolani

OBJECTIVEThe objective of the current study was to quantify and compare the multidirectional flexibility properties of sacral alar iliac fixation with conventional methods of sacral and sacroiliac fixation by using nondestructive and destructive investigative methods.METHODSTwenty-one cadaveric lumbopelvic spines were randomized into 3 groups based on reconstruction conditions: 1) S1–2 sacral screws; 2) sacral alar iliac screws; and 3) S1–iliac screws tested under unilateral and bilateral fixation. Nondestructive multidirectional flexibility testing was performed using a 6-degree-of-freedom spine simulator with moments of ± 12.5 Nm. Flexion-extension fatigue loading was then performed for 10,000 cycles, and the multidirectional flexibility analysis was repeated. Final destructive testing included an anterior flexural load to construct failure. Quantification of the lumbosacral and sacroiliac joint range of motion was normalized to the intact spine (100%), and flexural failure loads were reported in Newton-meters.RESULTSNormalized value comparisons between the intact spine and the 3 reconstruction groups demonstrated significant reductions in segmental flexion-extension, lateral bending, and axial rotation motion at L4–5 and L5–S1 (p < 0.05). The S1–2 sacral reconstruction group demonstrated significantly greater flexion-extension motion at the sacroiliac junction than the intact and comparative reconstruction groups (p < 0.05), whereas the sacral alar iliac group demonstrated significantly less motion at the sacroiliac joint in axial rotation (p < 0.05). Absolute value comparisons demonstrated similar findings. Under destructive anterior flexural loading, the S1–2 sacral group failed at 105 ± 23 Nm, and the sacral alar iliac and S1–iliac groups failed at 119 ± 39 Nm and 120 ± 28 Nm, respectively (p > 0.05).CONCLUSIONSAlong with difficult anatomy and weak bone, the large lumbosacral loads with cantilever pullout forces in this region are primary reasons for construct failure. All reconstructions significantly reduced flexibility at the L5–S1 junctions, as expected. Conventional S1–2 sacral fixation significantly increased sacroiliac motion under all loading modalities and demonstrated significantly higher flexion-extension motion than all other groups, and sacral alar iliac fixation reduced motion in axial rotation at the sacroiliac joint. Based on comprehensive multidirectional flexibility testing, the sacral alar iliac fixation technique reduced segmental motion under some loading modalities compared to S1–iliac screws and offers potential advantages of lower instrumentation profile and ease of assembly compared to conventional sacroiliac instrumentation techniques.


2019 ◽  
Vol 142 (1) ◽  
Author(s):  
Agnes Beckmann ◽  
Luis Fernando Nicolini ◽  
David Grevenstein ◽  
Hermann Backes ◽  
Stavros Oikonomidis ◽  
...  

Abstract Posterior dynamic stabilization systems (PDSS) were developed to provide stabilization to pathologic or hypermobile spinal segments while maintaining the healthy biomechanics of the spine. Numerous novel dynamic devices incorporate the temperature and moisture dependent material polycarbonate urethane (PCU) due to its mechanical properties and biocompatibility. In this study, standardized pure moment in vitro tests were carried out on human lumbar spines to evaluate the performance of a device containing PCU. An environmental chamber with controlled moisture and temperature was included in the setup to meet the requirements of testing under physiological conditions. Three test conditions were compared: (1) native spine, (2) dynamic instrumentation, and (3) dynamic instrumentation with decompression. The ranges of motion, centers of rotation, and relative pedicle screw motions were evaluated. The device displayed significant stiffening in flexion–extension, lateral bending, and axial rotation load directions. A reduction of the native range of motion diminished the stiffening effect along the spinal column and has the potential to reduce the risk of the onset of degeneration of an adjacent segment. In combination with decompression, the implant decreased the native range of motion for flexion–extension and skew bending, but not for lateral bending and axial rotation. Curve fittings using the sigmoid function were performed to parameterize all load-deflection curves in order to enhance accurate numerical model calibrations and comparisons. The device caused a shift of the center of rotation (COR) in the posterior and caudal direction during flexion–extension loading.


Neurosurgery ◽  
2010 ◽  
Vol 66 (2) ◽  
pp. E404-E406 ◽  
Author(s):  
Neil R. Crawford ◽  
Şeref Doğan ◽  
K. Zafer Yüksel ◽  
Octavio Villasana-Ramos ◽  
Julio C. Soto-Barraza ◽  
...  

Abstract OBJECTIVE A standard top-loading lumbar pedicle screw-rod system is compared with a pedicle screw-plate system with smaller-diameter screws, more medial entry, and lower profile to assess the relative stability, strength, and resistance to fatigue of the 2 systems. METHODS Seven human cadaveric specimens were studied with each surgical construct. Nondestructive, nonconstraining pure moments were applied to specimens to induce flexion, extension, lateral bending, and axial rotation while recording L5–S1 motion optoelectronically. After initial tests, specimens were fatigued for 10 000 cycles and retested to assess early postoperative loosening. Specimens were then loaded to failure in hyperextension. RESULTS The standard screw-rod construct reduced range of motion to a mean of 20% of normal, whereas the screw-plate construct reduced range of motion to 13% of normal. Differences between systems were not significant in any loading mode (P &gt; 0.06). The 14% loosening of the screw-rod system with fatigue was not significantly different from the 10% loosening observed with the screw-plate system (P &gt; 0.15). Mean failure loads of 30 Nm for screw-rod and 37 Nm for screw-plate were also not significantly different (P = 0.38). CONCLUSION Posterior fixation at L5–S1 using the low-profile screw-plate system offers stability, resistance to fatigue, and resistance to failure equivalent to fixation using a standard cantilevered pedicle screw-rod system.


Author(s):  
Héctor E Jaramillo S

The annulus fibrosus has substantial variations in its geometrical properties (among individuals and between levels), and plays an important role in the biomechanics of the spine. Few works have studied the influence of the geometrical properties including annulus area, anterior / posterior disc height, and over the range of motion, but in general these properties have not been reported in the finite element models. This paper presents a probabilistic finite element analyses (Abaqus 6.14.2) intended to assess the effects of the average disc height ( hp) and the area ( A) of the annulus fibrosus on the biomechanics of the lumbar spine. The annulus model was loaded under flexion, extension, lateral bending, and axial rotation and analyzed for different combinations of hpand A in order to obtain their effects over the range of motion. A set of 50 combinations of hp(mean = 18.1 mm, SD = 3.5 mm) and A (mean = 49.8%, SD = 4.6%) were determined randomly according to a normal distribution. A Yeoh energy function was used for the matrix and an exponential function for the fibers. The range of motion was more sensitive to hpthan to A. With regard to the range of motion the segment was more sensitive in the following order: flexion, axial rotation, extension, and lateral bending. An increase of the hpproduces an increase of the range of motion, but this decreases when A increases. Comparing the range of motion with the experimental data, on average, 56.0% and 73.0% of the total of data were within the experimental range for the L4–L5 and L5–S1 segments, respectively. Further, an analytic equation was derived to obtain the range of motion as a function of the hpand A. This equation can be used to calibrate a finite element model of the spine segment, and also to understand the influence of each geometrical parameter on the range of motion.


2008 ◽  
Vol 63 (suppl_4) ◽  
pp. ONS303-ONS308 ◽  
Author(s):  
Şeref Doğan ◽  
Seungwon Baek ◽  
Volker K.H. Sonntag ◽  
Neil R. Crawford

Abstract Objective: To evaluate the differences in spinal stability and stabilizing potential of instrumentation after cervical corpectomy and spondylectomy. Methods: Seven human cadaveric specimens were tested: 1) intact; 2) after grafted C5 corpectomy and anterior C4–C6 plate; 3) after adding posterior C4–C6 screws/rods; 4) after extending posteriorly to C3–C7; 5) after grafted C5 spondylectomy, anterior C4–C6 plate, and posterior C4–C6 screws/rods; and 6) after extending posteriorly to C3–C7. Pure moments induced flexion, extension, lateral bending, and axial rotation; angular motion was recorded optically. Results: After corpectomy, anterior plating alone reduced the angular range of motion to a mean of 30% of normal, whereas added posterior short- or long-segment hardware reduced range of motion significantly more (P &lt; 0.003), to less than 5% of normal. Constructs with posterior rods spanning C3–C7 were stiffer than constructs with posterior rods spanning C4–C6 during flexion, extension, and lateral bending (P &lt; 0.05), but not during axial rotation (P &gt; 0.07). Combined anterior and C4–C6 posterior fixation exhibited greater stiffness after corpectomy than after spondylectomy during lateral bending (P = 0.019) and axial rotation (P = 0.001). Combined anterior and C3–C7 posterior fixation exhibited greater stiffness after corpectomy than after spondylectomy during extension (P = 0.030) and axial rotation (P = 0.0001). Conclusion: Circumferential fixation provides more stability than anterior instrumentation alone after cervical corpectomy. After corpectomy or spondylectomy, long circumferential instrumentation provides better stability than short circumferential fixation except during axial rotation. Circumferential fixation more effectively prevents axial rotation after corpectomy than after spondylectomy.


Neurosurgery ◽  
2001 ◽  
Vol 49 (6) ◽  
pp. 1399-1408 ◽  
Author(s):  
Andrzej Maciejczak ◽  
Michał Ciach ◽  
Maciej Radek ◽  
Andrzej Radek ◽  
Jan Awrejcewicz

ABSTRACT OBJECTIVE To determine whether the Cloward technique of cervical discectomy and fusion increases immediate postoperative stiffness of single cervical motion segment after application of interbody dowel bone graft. METHODS We measured and compared the stiffness of single-motion segments in cadaveric cervical spines before and immediately after interbody fusion with the Cloward technique. Changes in range of motion and stiffness of the C5–C6 segment were measured in a bending flexibility test (flexion, extension, lateral bending and axial rotation) before and after a Cloward procedure in 11 fresh-frozen human cadaveric specimens from the 4th through the 7th vertebrae. RESULTS The Cloward procedure produced a statistically significant increase in stiffness of the operated segment in flexion and lateral bending when compared with the intact spine. The less stiff the segment before the operation, the greater the increase in its postoperative flexural stiffness (statistically significant). The Cloward procedure produced nonuniform changes in rotational and extensional stiffness that increased in some specimens and decreased in others. CONCLUSION Our data demonstrate that Cloward interbody fusion increases immediate postoperative stiffness of an operated segment only in flexion and lateral bending in cadaveric specimens in an in vitro environment. Thus, Cloward fusion seems a relatively ineffective method for increasing the stiffness of a construct. This may add to discussion on the use of spinal instrumentation and postoperative management of patients after cervical discectomy, which varies from bracing in hard collars through immobilization in soft collars to no external orthosis.


2020 ◽  
Vol 43 (12) ◽  
pp. 803-810 ◽  
Author(s):  
Masud Rana ◽  
Sandipan Roy ◽  
Palash Biswas ◽  
Shishir Kumar Biswas ◽  
Jayanta Kumar Biswas

The aim of this study is to design a novel expanding flexible rod device, for pedicle screw fixation to provide dynamic stability, based on strength and flexibility. Three-dimensional finite-element models of lumbar spine (L1-S) with flexible rod device on L3-L4-L5 levels are developed. The implant material is taken to be Ti-6Al-4V. The models are simulated under different boundary conditions, and the results are compared with intact model. In natural model, total range of motion under 10 Nm moment were found 66.7°, 24.3° and 13.59°, respectively during flexion–extension, lateral bending and axial rotation. The von Mises stress at intact bone was 4 ± 2 MPa and at bone, adjacent to the screw in the implanted bone, was 6 ± 3 MPa. The von Mises stress of disc of intact bone varied from 0.36 to 2.13 MPa while that of the disc between the fixed vertebra of the fixation model reduced by approximately 10% for flexion and 25% for extension compared to intact model. The von Mises stresses of pedicle screw were 120, 135, 110 and 90 MPa during flexion, extension, lateral bending, and axial rotation, respectively. All the stress values were within the safe limit of the material. Using the flexible rod device, flexibility was significantly increased in flexion/extension but not in axial rotation and lateral bending. The results suggest that dynamic stabilization system with respect to fusion is more effective for homogenizing the range of motion of the spine.