Integrated positron emission tomography and magnetic resonance imaging–guided resection of brain tumors: a report of 103 consecutive procedures

2006 ◽  
Vol 104 (2) ◽  
pp. 238-253 ◽  
Author(s):  
Benoît Pirotte ◽  
Serge Goldman ◽  
Olivier Dewitte ◽  
Nicolas Massager ◽  
David Wikler ◽  
...  

Object The aim of this study was to evaluate the integration of positron emission tomography (PET) scanning data into the image-guided resection of brain tumors. Methods Positron emission tomography scans obtained using fluorine-18 fluorodeoxyglucose (FDG) and l-[methyl-11C]methionine (MET) were combined with magnetic resonance (MR) images in the navigational planning of 103 resections of brain tumors (63 low-grade gliomas [LGGs] and 40 high-grade gliomas [HGGs]). These procedures were performed in 91 patients (57 males and 34 females) in whom tumor boundaries could not be accurately identified on MR images for navigation-based resection. The level and distribution of PET tracer uptake in the tumor were analyzed to define the lesion contours, which in turn yielded a PET volume. The PET scanning–demonstrated lesion volume was subsequently projected onto MR images and compared with MR imaging data (MR volume) to define a final target volume for navigation-based resection—the tumor contours were displayed in the microscope’s eyepiece. Maximal tumor resection was accomplished in each case, with the intention of removing the entire area of abnormal metabolic activity visualized during surgical planning. Early postoperative MR imaging and PET scanning studies were performed to assess the quality of tumor resection. Both pre- and postoperative analyses of MR and PET images revealed whether integrating PET data into the navigational planning contributed to improved tumor volume definition and tumor resection. Metabolic information on tumor heterogeneity or extent was useful in planning the surgery. In 83 (80%) of 103 procedures, PET studies contributed to defining a final target volume different from that obtained with MR imaging alone. Furthermore, FDG-PET scanning, which was performed in a majority of HGG cases, showed that PET volume was less extended than the MR volume in 16 of 21 cases and contributed to targeting the resection to the hypermetabolic (anaplastic) area in 11 (69%) of 16 cases. Performed in 59 LGG cases and 23 HGG cases, MET-PET demonstrated that the PET volume did not match the MR volume and improved the tumor volume definition in 52 (88%) of 59 and 18 (78%) of 23, respectively. Total resection of the area of increased PET tracer uptake was achieved in 54 (52%) of 103 procedures. Conclusions Imaging guidance with PET scanning provided independent and complementary information that helped to assess tumor extent and plan tumor resection better than with MR imaging guidance alone. The PET scanning guidance could help increase the amount of tumor removed and target image-guided resection to tumor portions that represent the highest evolving potential.

2002 ◽  
Vol 97 ◽  
pp. 542-550 ◽  
Author(s):  
Marc Levivier ◽  
David Wikler ◽  
Nicolas Massager ◽  
Philippe David ◽  
Daniel Devriendt ◽  
...  

Object. The authors review their experience with the clinical development and routine use of positron emission tomography (PET) during stereotactic procedures, including the use of PET-guided gamma knife radiosurgery (GKS). Methods. Techniques have been developed for the routine use of stereotactic PET, and accumulated experience using PET-guided stereotactic procedures over the past 10 years includes more than 150 stereotactic biopsies, 43 neuronavigation procedures, and 34 cases treated with GKS. Positron emission tomography—guided GKS was performed in 24 patients with primary brain tumors (four pilocytic astrocytomas, five low-grade astrocytomas or oligodendrogliomas, seven anaplastic astrocytomas or ependymomas, five glioblastomas, and three neurocytomas), five patients with metastases (single or multiple lesions), and five patients with pituitary adenomas. Conclusions. Data obtained with PET scanning can be integrated with GKS treatment planning, enabling access to metabolic information with high spatial accuracy. Positron emission tomography data can be successfully combined with magnetic resonance imaging data to provide specific information for defining the target volume for the radiosurgical treatment in patients with recurrent brain tumors, such as glioma, metastasis, and pituitary adenoma. This approach is particularly useful for optimizing target selection for infiltrating or ill-defined brain lesions. The use of PET scanning contributed data in 31 cases (93%) and information that was specifically utilized to adapt the target volume in 25 cases (74%). It would seem that the integration of PET data into GKS treatment planning may represent an important step toward further developments in radiosurgery: this approach provides additional information that may open new perspectives for the optimization of the treatment of brain tumors.


2011 ◽  
Vol 301-303 ◽  
pp. 1316-1321 ◽  
Author(s):  
Arthur E. Ruggles ◽  
Bi Yao Zhang ◽  
Spero M. Peters

Positron Emission Tomography (PET) produces a three dimensional spatial distribution of positron-electron annihilations within an image volume. Various positron emitters are available for use in aqueous, organic and liquid metal flows. Preliminary experiments at the University of Tennessee at Knoxville (UTK) injected small flows of PET tracer into a bulk water flow in a four rod bundle. The trajectory and diffusion of the tracer in the bulk flow were then mapped using a PET scanner. A spatial resolution of 1.4 mm is achieved with current preclinical Micro-PET imaging equipment resulting in 200 MB 3D activity fields. A time resolved 3-D spatial activity profile was also measured. The PET imaging method is especially well suited to complex geometries where traditional optical methods such as LDV and PIV are difficult to apply. PET methods are uniquely useful for imaging in opaque fluids, opaque pressure boundaries, and multiphase studies. Several commercial and shareware Computational Fluid Dynamics (CFD) codes are currently used for science and engineering analysis and design. These codes produce detailed three dimensional flow predictions. The models produced by these codes are often difficult to validate. The development of this experimental technique offers a modality for the comparison of CFD outcomes with experimental data. Developed data sets from PET can be used in verification and validation exercises of simulation outcomes.


1996 ◽  
Vol 84 (3) ◽  
pp. 494-502 ◽  
Author(s):  
Bernhard Zünkeler ◽  
Richard E. Carson ◽  
Jeffrey Olson ◽  
Ronald G. Blasberg ◽  
Mary Girton ◽  
...  

✓ Hyperosmolar blood-brain barrier (BBB) disruption remains controversial as an adjuvant therapy to increase delivery of water-soluble compounds to extracellular space in the brain in patients with malignant brain tumors. To understand the physiological effects of BBB disruption more clearly, the authors used positron emission tomography (PET) to study the time course of BBB permeability in response to the potassium analog rubidium-82 (82Rb, halflife 75 seconds) following BBB disruption in anesthetized adult baboons. Mannitol (25%) was injected into the carotid artery and PET scans were performed before and serially at 8- to 15-minute intervals after BBB disruption. The mean influx constant (K1), a measure of permeability-surface area product, in ipsilateral, mannitol-perfused mixed gray- and white-matter brain regions was 4.9 ± 2.4 µl/min/ml (± standard deviation) at baseline and increased more than 100% (ΔK1 = 9.4 ± 5.1 µl/min/ml, 18 baboons) in brain perfused by mannitol. The effect of BBB disruption on K1 correlated directly with the total amount of mannitol administered (p < 0.005). Vascular permeability returned to baseline with a halftime of 24.0 ± 14.3 minutes. The mean brain plasma volume rose by 0.57 ± 0.34 ml/100 ml in ipsilateral perfused brain following BBB disruption. This work provides a basis for the in vivo study of permeability changes induced by BBB disruption in human brain and brain tumors.


1987 ◽  
Vol 7 (2) ◽  
pp. 214-229 ◽  
Author(s):  
K. Herholz ◽  
C. S. Patlak

An analytical method based on Taylor expansions was developed to analyze errors caused by tissue heterogeneity in dynamic positron emission tomography (PET) measurements. Some general rules concerning the effect of parameter variances and covariances were derived. The method was further applied to various compartmental models currently used for measurement of blood flow, capillary permeability, glucose metabolism, and tracer binding. Blood flow and capillary permeability are shown to be generally underestimated in heterogenous tissue, the underestimation being more severe for slowly decaying, constant or increasing input functions rather than for bolus input, and increasing with measurement time. Typical errors caused by the heterogeneity due to insufficient separation between gray and white matter by a PET scanner with full width at half-maximum (FWHM)= 5 to 10 mm resolution range between–0.9 and–6% in dynamic CBF measurements with intravenous (i. v.) bolus injection of 15O-water or inhalation of 18F-fluoromethane and total measurement times of6 or 10 min, respectively. Binding or metabolic rates determined with tracers that are essentially trapped in tissue (e.g., FDG for measurement of cerebral glucose metabolism) are only slightly overestimated (0.5–3.0%) at typical measurement times and are essentially independent of the shape of the input function. The error increases considerably if tracer accumulation is very slow, however, or if short measurement times [<5/(k2 + k3)] are used. Some rate constants are also subject to larger errors.


2003 ◽  
Vol 21 (1) ◽  
pp. 33-39 ◽  
Author(s):  
Futoshi Mihara ◽  
Yasuo Kuwabara ◽  
Atsuo Tanaka ◽  
Takashi Yoshiura ◽  
Masayuki Sasaki ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document