Value of image-pro plus for assisting virtual touch tissue imaging in the diagnosis of thyroid nodules

Author(s):  
Kai-Mei Lian ◽  
Teng Lin

Purpose: The value of virtual touch tissue imaging (VTI) with support of Image-Pro Plus (IPP) for diagnosing malignant thyroid tumors was assessed in the present study. Methods: In this retrospective study, we enrolled 160 patients with 198 thyroid nodules. TI-RADS, VTI grade, and VTI with support of IPP (VTI-IPP) were underwent for each nodule. With the pathological diagnosis as the gold standard, the receiver-operating characteristic curve (ROC) was drawn to evaluate the diagnostic performance of VTI-IPP, VTI, TI-RADS, VTI-IPP combinate with TI-RADS in thyroid carcinoma. Results: VTI-IPP score >2, VTI score >3, TI-RADS score >1, and VTI-IPP combine with TI-RADS score >4 expressed the highest diagnostic value for malignant thyroid nodules, the areas under the curve (AUC) were 0.939, 0.905, 0.925, and 0.967, respectively. The combination indicated the largest AUC, compared with VTI-IPP and TI-RADS, respectively (P = 0.0054 and 0.0009). The performance of VTI-IPP in diagnosing thyroid carcinomas was better than VTI (P = 0.0321). Conclusion: Compare with VTI, VTI-IPP exhibited more excellent value in distinguishing between benign and malignant thyroid nodules. The value of malignant thyroid nodules diagnosis can be improved when VTI-IPP combines with TI-RADS.

2021 ◽  
Author(s):  
Xia Gan ◽  
Zhi-Yong Chen ◽  
Zi-Hua Li ◽  
Jian-Ming Zhou ◽  
Ying Sun ◽  
...  

Abstract Objective: Some conventional laboratory indicators have been found to be of value for the diagnosis of colorectal cancer (CRC). The present study aimed to systematically analyze the diagnostic value of conventional laboratory blood indicators for CRC, especially for early CRC. Methods: A total of 505 patients with CRC (n=210), colorectal adenoma (CRA) (n=167) or polyp (CRP) (n=128) were retrospectively collected. Clinical, laboratory and imaging data available before treatment were extracted. The diagnostic performances of laboratory blood indicators for discriminating total and early CRCs from CRA and CRP (CRA&P) were evaluated.Results: Fifty-three of 76 (69.7%) laboratory blood indicators were significant for discriminating CRC from CRA&P with areas under the receiver operating characteristic curve (AUC) ranging within 0.554-0.819, of these indicators, 17 had AUC > 0.7, three had AUC > 0.8, and five had AUCs greater than that for carcinoembryonic antigen (CEA). Fifteen indicators had overall sensitivities comparable to CEA for the diagnosis of CRC (35.7-55.4% vs. 47.7%, all P>0.05) at a specificity of 90%, and they were not or weakly correlated with CEA (absolute r = 0.058-0.333). For differentiating early CRC (TNM stage I+II, n=102) from CRA&P, the sensitivities for the 15 indicators ranged within 30.4%-55.5% at a specificity of 90% and similar to stage III+IV CRC.Conclusion: Conventional laboratory blood indicators are valuable for early CRC diagnosis, and are comparable to or better than CEA.


2019 ◽  
Vol 57 (6) ◽  
Author(s):  
Toine Mercier ◽  
Ellen Guldentops ◽  
Sofie Patteet ◽  
Kurt Beuselinck ◽  
Katrien Lagrou ◽  
...  

ABSTRACT Measuring serum beta-d-glucan (BDG) is a useful tool for supporting a quantitative PCR (qPCR)-based diagnosis of suspected Pneumocystis pneumonia (PCP) with bronchoalveolar lavage (BAL) fluid. Since the 2000s, the Fungitell assay was the only BDG assay which was FDA cleared and Conformité Européenne (CE) marked. However, the Wako β-glucan test was also recently CE marked and commercialized. We analyzed archived sera from 116 PCP cases (who were considered to have PCP based on compatible clinical and radiological findings plus a BAL fluid qPCR threshold cycle value of ≤28) and 114 controls (those with a BAL fluid qPCR threshold cycle value of >45 and no invasive fungal infection) using the Fungitell and Wako assays in parallel and assessed their diagnostic performance using the manufacturer’s proposed cutoffs of 80 pg/ml and 11 pg/ml, respectively. We found the Wako assay to be more specific (0.98 versus 0.87, P < 0.001) and the Fungitell assay to be more sensitive (0.78 versus 0.85, P = 0.039) at the proposed cutoffs. Overall performance, as determined by the area under the receiver operating characteristic curve, was similar for both assays. We determined a new Wako assay cutoff (3.616 pg/ml) to match the sensitivity of the Fungitell assay (0.88 at a cutoff of ≥60 pg/ml). Using this newly proposed cutoff, the specificity of the Wako assay was significantly better than that of the Fungitell assay (0.89 versus 0.82, P = 0.011). In conclusion, the Wako assay performed excellently compared to the Fungitell assay for the diagnosis of presumed PCP based on qPCR. In addition, contrary to the Fungitell assay, the Wako assay allows for single-sample testing with lower inter- and intrarun variability. Finally, we propose an optimized cutoff for the Wako assay to reliably exclude PCP.


Author(s):  
Chih-Yu Hsu ◽  
Rong-Ho Lin ◽  
Yu-Ching Lin ◽  
Jau-Yuan Chen ◽  
Wen-Cheng Li ◽  
...  

Body composition (BC) parameters are associated with cardiometabolic diseases in children; however, the importance of BC parameters for predicting pediatric hypertension is inconclusive. This cross-sectional study aimed to compare the difference in predictive values of BC parameters and conventional anthropometric measures for pediatric hypertension in school-aged children. A total of 340 children (177 girls and 163 boys) with a mean age of 8.8 ± 1.7 years and mean body mass index (BMI) z-score of 0.50 ± 1.24 were enrolled (102 hypertensive children and 238 normotensive children). Significantly higher values of anthropometric measures (BMI, BMI z-score, BMI percentile, waist-to-height ratio) and BC parameters (body-fat percentage, muscle weight, fat mass, fat-free mass) were observed among the hypertensive subgroup compared to their normotensive counterparts. A prediction model combining fat mass ≥ 3.65 kg and fat-free mass ≥ 34.65 kg (area under the receiver operating characteristic curve = 0.688; sensitivity = 66.7%; specificity = 89.9%) performed better than BMI alone (area under the receiver operating characteristic curve = 0.649; sensitivity = 55.9%; specificity = 73.9%) in predicting hypertension. In conclusion, BC parameters are better than anthropometric measures in predicting pediatric hypertension. BC measuring is a reasonable approach for risk stratification in pediatric hypertension.


Author(s):  
Leo Lam ◽  
Gerald A Woollard ◽  
Lochie Teague ◽  
James S Davidson

Background Urinary dopamine, homovanillic acid and 4-hydroxy-3-methoxymandelic acid are established tests for diagnosis and monitoring of neuroblastic disease. We compared the diagnostic performance of total urinary 3-methoxytyramine, the O-methylated product of dopamine, to these three established tumour markers. Methods Urinary 3-methoxytyramine, dopamine, homovanillic acid and 4-hydroxy-3-methoxymandelic acid were measured by high-performance liquid chromatography with electrochemical detection on consecutive urine samples from histologically proven neuroblastic patients and controls. Patients with neuroblastic disease were further classified as untreated, advancing, residual or absent disease based on clinical and radiological criteria. Receiver operating characteristic curve analysis was used to compare the diagnostic performance of the four tumour markers. Results Urinary 3-methoxytyramine was well correlated with established tumour markers and its concentration correlated with disease activity. It was the most commonly elevated tumour marker in neuroblastic disease and showed similar sensitivity to dopamine and homovanillic acid. The diagnostic utility of urinary 3-methoxytyramine as measured by area under the receiver operating characteristic curve was similar to dopamine and homovanillic acid. Conclusion Our results support the use of urinary 3-methoxytyramine as a tumour marker in the diagnosis and the monitoring of neuroblastoma disease.


2021 ◽  
pp. 019459982110513
Author(s):  
Aviva S. Mattingly ◽  
Julia E. Noel ◽  
Lisa A. Orloff

Objective To evaluate nodule height-to-width ratio as a continuous variable predicting likelihood of thyroid malignancy. Study Design Retrospective cohort study. Setting All study information was collected from a single academic tertiary care hospital. Methods Subjects included adult patients with thyroid nodules who underwent thyroid surgery between 2010 and 2020. The following variables were collected: patient demographics, nodule dimensions via ultrasound, fine-needle aspiration biopsy results, and surgical pathology results. Statistical analysis included logistic regression modeling malignancy with variables of interest. We used a receiver operating characteristic curve to assess the discriminatory value of variables. Results Height-to-width ratio, as a continuous variable, was associated with malignancy (with each 0.1 increase in ratio; odds ratio [OR], 1.25; 95% CI, 1.14-1.37). The same relationship was true for height-to-length ratio (OR, 1.36; 95% CI, 1.24-1.56). The area under the receiver operating characteristic curve for height-to-width ratio was 63.7%. In line with current emphasis on the transverse ultrasound view, we determined 4 different height-to-width ratio intervals: <0.8, 0.8 to <1.0, 1.0 to <1.5, and ≥1.5. Likelihood ratios of malignancy for each interval were 0.6, 1.0, 2.3, and 4.9, respectively. Conclusion Our results support the association between greater height-to-width ratio and malignancy but suggest that a multilevel rather than binary variable improves prediction. The likelihood ratios at different intervals give a more nuanced view of how height-to-width ratio predicts malignancy. With continuing review of guidelines for thyroid nodule biopsy, it is important to consider these data for any point total attributed to shape.


2020 ◽  
Vol 22 (4) ◽  
pp. 415
Author(s):  
Qi Wei ◽  
Shu-E Zeng ◽  
Li-Ping Wang ◽  
Yu-Jing Yan ◽  
Ting Wang ◽  
...  

Aims: To compare the diagnostic value of S-Detect (a computer aided diagnosis system using deep learning) in differentiating thyroid nodules in radiologists with different experience and to assess if S-Detect can improve the diagnostic performance of radiologists.Materials and methods: Between February 2018 and October 2019, 204 thyroid nodules in 181 patients were included. An experienced radiologist performed ultrasound for thyroid nodules and obtained the result of S-Detect. Four radiologists with different experience on thyroid ultrasound (Radiologist 1, 2, 3, 4 with 1, 4, 9, 20 years, respectively) analyzed the conventional ultrasound images of each thyroid nodule and made a diagnosis of “benign” or “malignant” based on the TI-RADS category. After referring to S-Detect results, they re-evaluated the diagnoses. The diagnostic performance of radiologists was analyzed before and after referring to the results of S-Detect.Results: The accuracy, sensitivity, specificity, positive predictive value and negative predictive value of S-Detect were 77.0, 91.3, 65.2, 68.3 and 90.1%, respectively. In comparison with the less experienced radiologists (radiologist 1 and 2), S-Detect had a higher area under receiver operating characteristic curve (AUC), accuracy and specificity (p <0.05). In comparison with the most experienced radiologist, the diagnostic accuracy and AUC were lower (p<0.05). In the less experienced radiologists, the diagnostic accuracy, specificity and AUC were significantly improved when combined with S-Detect (p<0.05), but not for experienced radiologists (radiologist 3 and 4) (p>0.05).Conclusions: S-Detect may become an additional diagnostic method for the diagnosis of thyroid nodules and improve the diagnostic performance of less experienced radiologists. 


2018 ◽  
Vol 142 (12) ◽  
pp. 1554-1559 ◽  
Author(s):  
Banseok Kim ◽  
Yongjung Park ◽  
Jin-Su Park ◽  
Kyoung Ja Jang ◽  
Hyo Jun Ahn ◽  
...  

Context.— Anticyclic citrullinated peptide antibodies are important serologic markers for the diagnosis of rheumatoid arthritis. Several kinds of test reagents for automated immunoassay systems have been developed and used in recent years. Objective.— To evaluate the analytic and diagnostic performance of the new ADVIA Centaur anticyclic citrullinated peptide assay (Siemens Healthineers, Erlangen, Germany) compared with the Elecsys assay (Roche Diagnostics, Mannheim, Germany). Design.— A total of 576 serum samples were collected from subjects, including 156 patients (27%) with rheumatoid arthritis. Precision performance and analytical measurement range for the ADVIA assay were evaluated. Diagnostic performance of the 2 assays was compared based on sensitivity, specificity, and area under the receiver operating characteristic curves. Results.— The ADVIA assay showed a within-laboratory imprecision of 3.4% coefficient of variation for levels of 3.36 and 24.99 U/mL. This assay was demonstrated to be linear from 0.4 to 180.0 U/mL. With default cutoff values, sensitivity and specificity for diagnosing rheumatoid arthritis were 71.2% and 97.9%, respectively, for the ADVIA assay and 73.1% and 96.9%, respectively, for the Elecsys assay. With the best cutoff values from the analyses of the receiver operating characteristic curve, the sensitivity of the 2 assays was the same at 75.6%. However, the specificity of the ADVIA assay was 96.4%, whereas that of the Elecsys assay was 94.3%. The area under the receiver operating characteristic curve value for the ADVIA assay was 0.867, which was not significantly different from that of the Elecsys assay (0.865). Conclusions.— The ADVIA Centaur anticyclic citrullinated peptide assay showed good analytic and diagnostic performance in diagnosing rheumatoid arthritis.


Sign in / Sign up

Export Citation Format

Share Document