scholarly journals USING ADSORPTION CHILLER IN SOLAR COOLING: ECONOMIC BENEFITS FOR JORDAN

2021 ◽  
Vol 11 (6) ◽  
pp. 234-242
Author(s):  
Abdul Ghafour Saidi ◽  
Ghani Albaali ◽  
Mohammed Issa Shahateet ◽  
Suleiman Mohammad ◽  
Zaid Omar Daher
Energies ◽  
2020 ◽  
Vol 13 (22) ◽  
pp. 5931
Author(s):  
M.T. Nitsas ◽  
E.G. Papoutsis ◽  
I.P. Koronaki

Heat-driven coolers provide a reliable and environmentally benign alternative to traditional electrically powered chillers. Their main advantage is that they can be driven using low enthalpy heat sources. A solar system is installed at the school of Mechanical Engineering of National Technical University of Athens in order to examine the potential of thermal storage and solar cooling under Athens climatic conditions. The cooling effect is produced using a dual bed, single stage, zeolite/water adsorption chiller with cooling capacity of 10 kW at its nominal conditions of operation. Both vacuum tube collectors and hybrid photovoltaic thermal collectors are installed in order to supply the system with heat. The system is evaluated in terms of solar collectors’ useful energy production, heat stored in the intermediate buffer and cooling system’s performance. It is observed that the cooling system operates satisfactorily under Athens climatic conditions achieving a maximum cooling capacity of 3.7 kW and an average COP around 0.5.


2016 ◽  
Author(s):  
I. P. Koronaki ◽  
E. G. Papoutsis ◽  
M. T. Nitsas

Solar cooling systems offer a reliable and environmentally friendly alternative to conventional electrically driven vapor compression cooling units. Air conditioning systems powered by solar energy are very attractive because they have zero ozone depletion and global warming potential, their operational cost is low and they do not burden the electrical network during summer months. In this study, the installation of a solar cooling system in various Greek cities is examined. The system utilizes a single-stage, two-bed silica gel-water adsorption chiller driven by heat produced by solar collectors. A lumped parameter model is used to simulate the performance of the adsorption chiller. The optimum tilt of the solar collectors is calculated for each examined city in order for the collected solar energy to be maximized during the summer period (April to September). The climatic data are taken from the technical notes of Greek Regulation for Buildings Energy Performance. Then, using the f-chart cooling method the necessary collectors’ surface area is estimated for every examined city and for different types of flat plate collectors (including advanced flat plate, simple flat plate and hybrid photovoltaic thermal collectors).


2021 ◽  
Vol 312 ◽  
pp. 08014
Author(s):  
Giovanni Brumana ◽  
Giuseppe Franchini ◽  
Elisa Ghirardi

The paper presents a complete solar cooling comparison. A detailed model of a tertiary sector building has been evaluated in three locations (Riyadh, Abu Dhabi, and Palermo) and coupled with four solar cooling systems: two solar thermal cooling systems (Li-Br absorption chiller and adsorption chiller), a solar Desiccant Evaporative Cooling system and a solar electric cooling (Photovoltaic coupled with Compression chiller). A multi-variable optimization procedure selects the optimal size of each component. The results show that the solar cooling system based on absorption chiller satisfied the cooling demand regardless of the site location whilst the performance of the Desiccant Evaporative Cooling system is dramatically affected by ambient conditions. The electric solar cooling option shows the best overall efficiency and appears a costeffective solution despite the high cost of the storage system.


2015 ◽  
Author(s):  
Marco Badami ◽  
Armando Portoraro ◽  
Marco Simonetti ◽  
Paolo Tebaldi

Low power adsorption chillers with low desorption temperatures deserve particular attention, because of the possibility of driving them with a solar thermal system integrated with buildings. The monitoring of a recent solar cooling installation in Turin, Italy, has pointed out the opportunity of developing a dynamic mathematical model, in order to simulate the transient performances of this plant. Focusing on the aforementioned low power-low temperature adsorption chiller category, this work proposes a numerical model of the systems, that include a novel zeolite as the adsorbent and water as the refrigerant fluid. The simulation results have been verified by means of the nominal values of one of the very few commercial chillers of this typology available on the market, and have compared with experimental data found in the literature for similar plants.


1980 ◽  
Vol 19 (03) ◽  
pp. 125-132
Author(s):  
G. S. Lodwick ◽  
C. R. Wickizer ◽  
E. Dickhaus

The Missouri Automated Radiology System recently passed its tenth year of clinical operation at the University of Missouri. This article presents the views of a radiologist who has been instrumental in the conceptual development and administrative support of MARS for most of this period, an economist who evaluated MARS from 1972 to 1974 as part of her doctoral dissertation, and a computer scientist who has worked for two years in the development of a Standard MUMPS version of MARS. The first section provides a historical perspective. The second deals with economic considerations of the present MARS system, and suggests those improvements which offer the greatest economic benefits. The final section discusses the new approaches employed in the latest version of MARS, as well as areas for further application in the overall radiology and hospital environment. A complete bibliography on MARS is provided for further reading.


1997 ◽  
Vol 77 (03) ◽  
pp. 436-439 ◽  
Author(s):  
Armando Tripodi ◽  
Barbara Negri ◽  
Rogier M Bertina ◽  
Pier Mannuccio Mannucci

SummaryThe factor V (FV) mutation Q506 that causes resistance to activated protein C (APC) is the genetic defect associated most frequently with venous thrombosis. The laboratory diagnosis can be made by DNA analysis or by clotting tests that measure the degree of prolongation of plasma clotting time upon addition of APC. Home-made and commercial methods are available but no comparative evaluation of their diagnostic efficacy has so far been reported. Eighty frozen coded plasma samples from carriers and non-carriers of the FV: Q506 mutation, diagnosed by DNA analysis, were sent to 8 experienced laboratories that were asked to analyze these samples in blind with their own APC resistance tests. The APTT methods were highly variable in their capacity to discriminate between carriers and non-carriers but this capacity increased dramatically when samples were diluted with FV-deficient plasma before analysis, bringing the sensitivity and specificity of these tests to 100%. The best discrimination was obtained with methods in which fibrin formation is triggered by the addition of activated factor X or Russell viper venom. In conclusion, this study provides evidence that some coagulation tests are able to distinguish carriers of the FV: Q506 mutation from non-carriers as well as the DNA test. They are inexpensive and easy to perform. Their use in large-scale clinical trials should be of help to determine the medical and economic benefits of screening healthy individuals for the mutation before they are exposed to such risk factors for venous thrombosis as surgery, pregnancy and oral contraceptives.


Sign in / Sign up

Export Citation Format

Share Document