scholarly journals Analysis of Amoxicillin and Tetracycline Residues in Chicken Meat Using High Performance Liquid Chromatography-Mass Spectrometry

2018 ◽  
Vol 1 (2) ◽  
pp. 14-20
Author(s):  
Mustika Furi ◽  
Siti Morin Sinaga ◽  
Effendy De Lux Putra

Antibiotics are commonly used as food additives in broiler farms and their use tends to be excessive regardless and incorrect that can leave some antibiotic residues in chicken meat. The aimed of this study was to analyze on  antibiotic residues level amoxicillin and tetracycline in chicken meat sold in Medan. The antibiotic residues analysis was conducted by extracting the antibiotic from chicken meat with water and acetonitrile (2:8, v/v) and detected by high performance liquid chromatography-mass spectrometry detector using C-18 column (4.6 mm i.d., length 30 mm, particle size 1.8 µm) at 35 oC, with the mobile phases,  0.1 % formic acid solution in water and 0.1 % formic acid solution in methanol with gradient elution technique at a flow rate of  0.5 ml/minute. The result exhibited that the chicken meat that were collected from five  markets  in Medan apparently contained antibiotic residues  tetracycline . The level of  tetracyclin residue in chicken meat was  0.1157-1.4436 µg/g, which exceed the maximum level  for tetracyclin residue allowed in foodstuffs of animal origin which is 0.1 ug/g.   Keywords: residue, antibiotic, amoxicillin, tetracycline, chicken meat

Author(s):  
Liliya Logoyda

Objective: A simple, rapid high-performance liquid chromatography-mass spectrometry (HPLC MS/MS) method was developed for the determination of enalapril maleate from confluent Caco-2 monolayers and aqueous solution.Methods: Chromatography was achieved on Discovery C18, 50×2.1 mm, 5 μm column. Samples were chromatographed in a gradient mode (eluent A [acetonitrile-water-formic acid, 5: 95:0.1 v/v] and eluent B [acetonitrile-formic acid, 100:0.1 v/v]). The initial content of the eluent B is 0%, which increases linearly by 1.0 min to 100% and 1.01 min returns to the initial 0%. The mobile phase was delivered at a flow rate of 0.4 ml/min into the mass spectrometer ESI chamber. The sample volume was 5 μl.Results: Under these conditions, enalapril maleate was eluted at 1.52 min. According to the Caco-2 test results, enalapril showed low permeability. It should be noted that the recovery value for enalapril is 100.62 %. Low in vitro permeability data for enalapril are in good agreement with the literature data.Conclusion: From results of the analysis, it can be concluded that developed method is simple and rapid for determination of enalapril maleate from confluent Caco-2 monolayers and aqueous solution. Acquired results demonstrate that proposed strategy can be effortlessly and advantageously applied for examination of enalapril from Caco-2 cell monolayers.


Author(s):  
Liliya Logoyda

Objective: A simple, rapid high-performance liquid chromatography–mass spectrometry/mass spectrometry (MS/MS) method was developed for the determination of amlodipine from confluent Caco-2 monolayers and from aqueous solution.Methods: Chromatography was achieved on Discovery C18, 50×2.1 mm, 5 μm column. Samples were chromatographed in a gradient mode (eluent A [acetonitrile-water-formic acid, 5:95:0.1 v/v], eluent B [acetonitrile-formic acid, 100:0.1 v/v]). The initial content of the eluent B is 0%, which increases linearly by 1.0 min to 100% and to 1.01 min returns to the initial 0%. The mobile phase was delivered at a flow rate of 0.400 ml/min into the MS electrospray ionization chamber. The sample volume was 5 μl.Results: Under these conditions, amlodipine was eluted at 1.61 min. According to the Caco-2 test results, amlodipine appeared to have moderate to high permeability. Recovery value for amlodipine is 52.33%. Caco-2 permeability values for amlodipine are in agreement with BCS Class I classification for these drugs and their known high bioavailability in humans.Conclusion: A new rapid method was developed for the determination of amlodipine from confluent Caco-2 monolayers and from aqueous solution. Acquired results demonstrate that proposed strategy can be effortlessly and advantageously applied for the examination of amlodipine from Caco-2 cell monolayers.


Sign in / Sign up

Export Citation Format

Share Document