158. Computational Fluid Dynamics and Residence Time Distributions to Characterize Dilution Ventilation in a Confined Space Model

1999 ◽  
Author(s):  
R. Nabar ◽  
C. Kauffman ◽  
R. Garrison
2020 ◽  
Vol 8 (1) ◽  
Author(s):  
Tim Padfield ◽  
Nicolas Padfield ◽  
Daniel Sang-Hoon Lee ◽  
Anne Thøgersen ◽  
Astrid Valbjørn Nielsen ◽  
...  

Abstract In this paper different scenarios for back protection of a canvas painting and their effect on the stability of the relative humidity behind the painting are tested. A painting on canvas, stretched on a wooden frame, was fitted with various styles of back protection and then exposed to a cycle of temperature variation at the back, with the front exposed to a constant room temperature. The painting was also exposed to a constant wall temperature and varying room temperature. The space between the canvas and the back board was fitted with temperature and relative humidity (RH) sensors. The sensors were used to provide the essential single-point data of temperature and RH at the given locations. For more comprehensive understanding of the rather confined space, further numerical simulation (computational fluid dynamics) was adopted as part of the investigation. The computational fluid dynamics was used to understand the natural convection within the microclimate through the depictions of temperature distribution, as well as the corresponding airflow. The unprotected painting suffered a large RH variation at its back, because of the varying canvas temperature interacting with the constant room air moisture content. Effective stabilisation of the RH behind the canvas against temperature variation was provided by a shiny aluminium alloy sheet sealed against the frame. The non-absorbent back board experienced a strong variation in RH, because of humidity buffering of the space by the painting canvas at a different temperature. Either a space or insulation between this back plate and the wall reduced the risk of condensation on the inner surface of the back plate. Insulation will however increase the risk of condensation on the wall surface behind the painting. An absorbent back board de-stabilised the RH at the painting canvas surface by providing a competing humidity buffer at a different temperature. To provide protection against moisture exchange with an unsuitable room RH, extra humidity buffer was placed 3 mm behind the painting canvas, kept close to the painting temperature by insulation between this buffer and the back board. This stabilised RH at the canvas surface but increased both the temperature and the RH variation at the back board and thus increased the risk of condensation on the inner surface of the back board. The RH and the temperature in the narrow spaces between the painting canvas and the wooden stretcher frame were always more nearly constant than in the open canvas area, which suggests an explanation for the widely observed better condition of the areas of canvas paintings which lie close over the support structure. Our conclusion is that a non-absorbent, impermeable back plate gives good RH stability against a changing temperature gradient between wall and canvas painting surface.


2018 ◽  
Vol 16 (5) ◽  
pp. 750-761 ◽  
Author(s):  
J. Zhang ◽  
N. Sinha ◽  
M. Ross ◽  
A. E. Tejada-Martínez

Abstract Hydraulic or filtration efficiency of residential swimming pools, quantified in terms of residence time characteristics, is critical to disinfection and thus important to public health. In this study, a three-dimensional computational fluid dynamics model together with Eulerian and Lagrangian-based techniques are used for investigating the residence time characteristics of a passive tracer and particles in the water, representative of chemicals and pathogens, respectively. The flow pattern in the pool is found to be characterized by dead zone regions where water constituents may be retained for extended periods of times, thereby potentially decreasing the pool hydraulic efficiency. Two return-jet configurations are studied in order to understand the effect of return-jet location and intensity on the hydraulic efficiency of the pool. A two-jet configuration is found to perform on par with a three-jet configuration in removing dissolved constituents but the former is more efficient than the latter in removing or flushing particles. The latter result suggests that return-jet location and associated flow circulation pattern have an important impact on hydraulic efficiency. Thus return-jet configuration should be incorporated as a key parameter in the design of swimming pools complementing current design standards.


Water ◽  
2018 ◽  
Vol 10 (6) ◽  
pp. 733 ◽  
Author(s):  
Daniel Hernández-Cervantes ◽  
Xitlali Delgado-Galván ◽  
José Nava ◽  
P. López-Jiménez ◽  
Mario Rosales ◽  
...  

Author(s):  
Terry Potter ◽  
Tathagata Acharya

Abstract Multiphase separators on production platforms are among the first equipment through which well fluids flow. Based on functionality, multiphase separators can either be two-phase that separate oil from water, or three-phase that separate oil, natural gas, and water. Separator performances are often evaluated using mean residence time (MRT) of the hydrocarbon phase. MRT is defined as the amount of time a given phase stays inside the separator. On field, operators usually measure MRT as the ratio of active volume occupied by each phase to the phase volumetric flowrate. However, this method may involve significant errors as the oil-water interface height is obtained using level controllers and the volume occupied by each phase is calculated assuming the interface can be extrapolated from the weir back to the separator inlet. In this study, authors perform computational fluid dynamics (CFD) on a two-phase horizontal separator to evaluate MRT as a function of varying water volume flowrates (water-cut) in a mixture of water and oil. The authors use residence time distributions (RTD) to obtain MRT at each water-cut — a method that results in significantly more accurate results than the regular method used by operators. The numerical model is developed with commercial software package ANSYS Fluent. The code uses the Eulerian multiphase model along with the k-ε turbulence model. The simulation results show agreement with experiments performed by previous researchers. Additional simulations are performed to assess the effect of various separator internals on separator performance. Simulation results suggest that the model developed in this study can be used to predict performances of two-phase liquid-liquid separators with reasonable accuracy and will be useful towards their design to improve performances under various inlet flow conditions.


Perfusion ◽  
2019 ◽  
Vol 35 (4) ◽  
pp. 306-315
Author(s):  
Muhammad Jamil ◽  
Mohammad Rezaeimoghaddam ◽  
Bilgesu Cakmak ◽  
Yahya Yildiz ◽  
Reza Rasooli ◽  
...  

Objective: Malposition of dual lumen cannula is a frequent and challenging complication in neonates and plays a significant role in shaping the in vitro device hemodynamics. This study aims to analyze the effect of the dual lumen cannula malposition on right-atrial hemodynamics in neonatal patients using an experimentally validated computational fluid dynamics model. Methods: A computer model was developed for clinically approved dual lumen cannula (13Fr Origen Biomedical, Austin, Texas, USA) oriented inside the atrium of a 3-kg neonate with normal venous return. Atrial hemodynamics and dual lumen cannula malposition were systematically simulated for two rotations (antero-atrial and atrio-septal) and four translations (two intravascular movements along inferior vena cava and two dislodged configurations in the atrium). A multi-domain compartmentalized mesh was prepared to allow the site-specific evaluation of important hemodynamic parameters. Transport of each blood stream, blood damage levels, and recirculation times are quantified and compared to dual lumen cannula in proper position. Results: High recirculation levels (39 ± 4%) in malpositioned cases resulted in poor oxygen saturation where maximum recirculation of up to 42% was observed. Apparently, Origen dual lumen cannula showed poor inferior vena cava blood–capturing efficiency (48 ± 8%) but high superior vena cava blood–capturing efficiency (86 ± 10%). Dual lumen cannula malposition resulted in corresponding changes in residence time (1.7 ± 0.5 seconds through the tricuspid). No significant differences in blood damage were observed among the simulated cases compared to normal orientation. Compared to the correct dual lumen cannula position, both rotational and translational displacements of the dual lumen cannula resulted in significant hemodynamic differences. Conclusion: Rotational or translational movement of dual lumen cannula is the determining factor for atrial hemodynamics, venous capturing efficiency, blood residence time, and oxygenated blood delivery. Results obtained through computational fluid dynamics methodology can provide valuable foresight in assessing the performance of the dual lumen cannula in patient-specific configurations.


2020 ◽  
Vol 10 (19) ◽  
pp. 6954
Author(s):  
Štěpán Papáček ◽  
Karel Petera ◽  
Petr Císař ◽  
Vlastimil Stejskal ◽  
Mohammadmehdi Saberioon

Fish feed delivery is one of the challenges which fish farmers encounter daily. The main aim of the feeding process is to ensure that every fish is provided with sufficient feed to maintain desired growth rates. The properties of fish feed pellet, such as water stability, degree of swelling or floating time, are critical traits impacting feed delivery. Some considerable effort is currently being made with regard to the replacement of fish meal and fish oil with other sustainable alternative raw materials (i.e., plant or insect-based) with different properties. The main aim of this study is to investigate the motion and residence time distribution (RTD) of two types of solid feed pellets with different properties in a cylindrical fish tank. After experimental identification of material and geometrical properties of both types of pellets, a detailed 3D computational fluid dynamics (CFD) study for each type of pellets is performed. The mean residence time of pellets injected at the surface of the fish tank can differ by up to 75% depending on the position of the injection. The smallest residence time is when the position is located at the center of the liquid surface (17 s); the largest is near the edge of the tank (75 s). The maximum difference between the two studied types of pellets is 25% and it increases with positions closer to the center of the tank. The maximum difference for positions along the perimeter at 3/4 tank radius is 8%; the largest residence times are observed at the opposite side of the water inlet. Based on this study, we argue that the suitability of different solid feed pellets for aquaculture systems with specific fish can be determined, and eventually the pellet composition (formula) as well as the injection position can be optimized.


Sign in / Sign up

Export Citation Format

Share Document