Conventional immunoassay methods have their common defects, such as tedious processing steps and inadequate sensitivity, in detecting whole blood. To overcome the above problems, we report a microfluidic chip–based magnetic relaxation switching (MRS) immunosensor via enzyme-mediated nanoparticles to simplify operation and amplify the signal in detecting whole blood samples. In the silver mirror reaction with catalase (CAT) as the catalyst, H2O2 can effectively control the production of Ag NPs. The amount of Ag NPs formed further affects the degree of aggregation of magnetic nanoparticles (MNPS), which gives rise to the changes of transverse relaxation time (T2). Both sample addition and reagent reaction are carried out in the microfluidic chip, thereby saving time and reagent consumption. We also successfully apply the sensor to detect alpha-fetoprotein (AFP) in real samples with a satisfied limit of detection (LOD = 0.56 ng/ml), which is superior to the conventional ELISA.

2021 ◽  
Vol 27 (Supplement_1) ◽  
pp. S57-S57
Author(s):  
Edgar Ong ◽  
Ruo Huang ◽  
Richard Kirkland ◽  
Michael Hale ◽  
Larry Mimms

Abstract Introduction A fast (<5 min), time-resolved fluorescence resonance energy transfer (FRET)-based immunoassay was developed for the quantitative detection of infliximab (IFX) and biosimilars for use in therapeutic drug monitoring using only 20 µL of fingerstick whole blood or serum at the point-of-care. The Procise IFX assay and ProciseDx analyzer are CE-marked. Studies were performed to characterize analytical performance of the Procise IFX assay on the ProciseDx analyzer. Methods Analytical testing was performed by spiking known amounts of IFX into negative serum and whole blood specimens. Analytical sensitivity was determined using limiting concentrations of IFX. Linearity was determined by testing IFX across the assay range. Hook effect was assessed at IFX concentrations beyond levels expected to be found within a patient. Testing of assay precision, cross-reactivity and potential interfering substances, and biosimilars was performed. The Procise IFX assay was also compared head-to-head with another CE-marked assay: LISA-TRACKER infliximab ELISA test (Theradiag, France). The accuracy of the Procise IFX assay is established through calibrators and controls traceable to the WHO 1st International Standard for Infliximab (NIBSC code: 16/170). Results The Procise IFX assay shows a Limit of Blank, Limit of Detection, and Lower Limit of Quantitation (LLoQ) of 0.1, 0.2, and 1.1 µg/mL in serum and 0.6, 1.1, and 1.7 µg/mL in whole blood, respectively. The linear assay range was determined to be 1.7 to 77.2 µg/mL in serum and whole blood. No hook effect was observed at an IFX concentration of 200 µg/mL as the value reported as “>ULoQ”. Assay precision testing across 20 days with multiple runs and reagent lots showed an intra-assay coefficient of variation (CV) of 2.7%, an inter-assay CV of <2%, and a total CV of 3.4%. The presence of potentially interfering/cross-reacting substances showed minimal impact on assay specificity with %bias within ±8% of control. Testing of biosimilars (infliximab-dyyb and infliximab-abda) showed good recovery. A good correlation to the Theradiag infliximab ELISA was obtained for both serum (slope=1.01; r=0.99) and whole blood (slope=1.01; r=0.98) samples (Figure 1). Conclusion Results indicate that the Procise IFX assay is sensitive, specific, and precise yielding results within 5 minutes from both whole blood and serum without the operator needing to specify sample type. Additionally, it shows very good correlation to a comparator assay that takes several hours and sample manipulation to yield results. This makes the Procise IFX assay ideal for obtaining fast and accurate IFX quantitation, thus allowing for immediate drug level dosing decisions to be made by the physician during patient treatment.


Sensors ◽  
2021 ◽  
Vol 21 (12) ◽  
pp. 4166
Author(s):  
Román Fernández ◽  
María Calero ◽  
Yolanda Jiménez ◽  
Antonio Arnau

Monolithic quartz crystal microbalance (MQCM) has recently emerged as a very promising technology suitable for biosensing applications. These devices consist of an array of miniaturized QCM sensors integrated within the same quartz substrate capable of detecting multiple target analytes simultaneously. Their relevant benefits include high throughput, low cost per sensor unit, low sample/reagent consumption and fast sensing response. Despite the great potential of MQCM, unwanted environmental factors (e.g., temperature, humidity, vibrations, or pressure) and perturbations intrinsic to the sensor setup (e.g., mechanical stress exerted by the measurement cell or electronic noise of the characterization system) can affect sensor stability, masking the signal of interest and degrading the limit of detection (LoD). Here, we present a method based on the discrete wavelet transform (DWT) to improve the stability of the resonance frequency and dissipation signals in real time. The method takes advantage of the similarity among the noise patterns of the resonators integrated in an MQCM device to mitigate disturbing factors that impact on sensor response. Performance of the method is validated by studying the adsorption of proteins (neutravidin and biotinylated albumin) under external controlled factors (temperature and pressure/flow rate) that simulate unwanted disturbances.


2021 ◽  
Vol 156 (Supplement_1) ◽  
pp. S134-S135
Author(s):  
T Berent ◽  
T Rothstein ◽  
S Buckwalter ◽  
R Patel

Abstract Introduction/Objective Molecular assays for Bartonella species are important in diagnosing infection and expediting patient treatment. Real time polymerase chain reaction (RT-PCR) using fluorescent resonance energy transfer (FRET) hybridization probes can be used to detect Bartonella species in blood and fresh/fixed tissue biopsies in RT-PCR instruments. Over time, new technologies and reagents are introduced and existing PCR primers and FRET probes must be re-validated on new platforms. This study aimed to compare the performance of a Bartonella RT-PCR assay using the sunsetting Roche LightCycler® 2.0 (Roche Diagnostics, Indianapolis, IN) and newer LightCycler® 480 RT- PCR instruments. Methods/Case Report DNA was extracted from 132 historically positive, whole organism spiked, and historically negative whole blood and formalin fixed paraffin embedded (FFPE) samples. Samples were run on the LightCycler® 2.0 using instrument specific LightCycler® FastStart DNA Master HybProbe enzyme and compared to results generated using the LightCycler® 480 and its instrument specific LightCycler® 480 Genotyping Master enzyme. During optimization, MgCl2 concentrations and thermocycling profiles were adjusted. Accuracy, specificity, inclusivity, and limit of detection studies were performed. Crossing point (Cp), melting temperature (Tm), fluorescent peak and fluorescent background values were compared between the two instruments. Results (if a Case Study enter NA) The agreement in accuracy between the LightCycler® 2.0 and the LightCycler® 480 was 100% for whole blood samples. For historically positive FFPE samples, LightCycler® 2.0 sensitivity and LightCycler® 480 sensitivity were 86% and 100%, respectively. Specificity and inclusivity of the assay were identical between the two instruments. The limit of detection in whole blood was 5-fold lower on the LightCycler® 480 (50 copies/µL) compared to the LightCycler® 2.0 (250 copies/µL). Mean Cp and fluorescent peak intensity values increased by 5.1% and 65-fold, respectively. Conclusion The study demonstrates similar performance and improved limit of detection for the Bartonella FRET hybridization probe RT-PCR assay on the LightCycler® 480 compared to the LightCycler® 2.0.


Geophysics ◽  
2019 ◽  
Vol 84 (2) ◽  
pp. MR73-MR84 ◽  
Author(s):  
Fatemeh Razavirad ◽  
Myriam Schmutz ◽  
Andrew Binley

We have evaluated several published models using induced polarization (IP) and nuclear magnetic resonance (NMR) measurements for the estimation of permeability of hydrocarbon reservoir samples. IP and NMR measurements were made on 30 samples (clean sands and sandstones) from a Persian Gulf hydrocarbon reservoir. We assessed the applicability of a mechanistic IP-permeability model and an empirical IP-permeability model recently proposed. The mechanistic model results in a broader range of permeability estimates than those measured for sand samples, whereas the empirical model tends to overestimate the permeability of the samples that we tested. We also evaluated an NMR permeability prediction model that is based on porosity [Formula: see text] and the mean of the log transverse relaxation time ([Formula: see text]). This model provides reasonable permeability estimations for the clean sandstones that we tested but relies on calibrated parameters. We also examined an IP-NMR permeability model, which is based on the peak of the transverse relaxation time distribution, [Formula: see text] and the formation factor. This model consistently underestimates the permeability of the samples tested. We also evaluated a new model. This model estimates the permeability using the arithmetic mean of log transverse NMR relaxation time ([Formula: see text]) and diffusion coefficient of the pore fluid. Using this model, we improved estimates of permeability for sandstones and sand samples. This permeability model may offer a practical solution for geophysically derived estimates of permeability in the field, although testing on a larger database of clean granular materials is needed.


2016 ◽  
Vol 31 (3) ◽  
Author(s):  
Gabriele Bianco ◽  
Cristina Costa ◽  
Andrea Piceghello ◽  
Francesca Sidoti ◽  
Mareva Giacchino ◽  
...  

In this study, the occurrence and clinical impact of adenovirus (AdV) infection was investigated in paediatric hematopoietic stem cell transplantation (HSCT) recipients. A number of 603 specimens (including whole blood, respiratory and other samples) from 181 patients were tested by real-time polymerase chain reaction; clinical outcome was investigated. Overall, 118/603 (19.6%) specimens from 21/181 (11.6%) patients resulted positive to AdV (including 17.3, 29.9, 17.6, and 15.8% of total number of whole blood, respiratory, urine and other specimens, respectively). On whole blood specimens, viral loads ranged from &lt;600 (limit of detection) to &gt;5×10<sup>6</sup> copies/mL, with a median value 2×104. Multiple specimens were positive in patients in which viral load on whole blood was high. Adenoviral positivity on whole blood was associated to poor prognosis, as death occurred in three of ten (30%) patients with persistent positivity on whole blood specimens, also despite the administration of an antiviral agent (cidofovir). Adenovirus infection can account for systemic and/or organ-specific signs/symptoms in approximately 10% of paediatric HSCT recipients. At moment, there is no indication for routine monitor of AdV in these patients, although AdV aetiology of infectious transplant complications should be taken in account.