scholarly journals Clinical and Angiographic Outcomes After Stent-Assisted Coiling of Cerebral Aneurysms With Laser-Cut and Braided Stents: A Comparative Analysis of the Literatures

2021 ◽  
Vol 12 ◽  
Author(s):  
Longhui Zhang ◽  
Xiheng Chen ◽  
Linggen Dong ◽  
Peng Liu ◽  
Luqiong Jia ◽  
...  

Introduction: Stent-assisted coiling (SAC) plays an important role in endovascular treatment of intracranial aneurysms (IAs). This comparative analysis examines the safety and efficacy of SAC in general and compares clinical and angiographic outcomes between laser-cut stents and braided stents.Methods: Relevant English-language studies were identified via a PubMed search for published articles regarding outcomes of SAC using laser-cut stents and braided stents published from 2015 to 2020. Data from 56 studies that met our inclusion criteria were pooled and statistically compared.Results: A total of 4,373 patients harboring with 4,540 IAs were included. Patients were divided into two groups on the basis of stent type: laser-cut stents (2,076 aneurysms in 1991 patients; mean follow-up, 12.99 months) and braided stents (2,464 aneurysms in 2382 patients; mean follow-up, 18.41 months). Overall, the rates of successful stent deployment, thromboembolic events, stent stenosis, periprocedural intracranial hemorrhage, permanent morbidity, mortality, and recanalization were 97.72, 4.72, 2.87, 1.51, 2.14, 1.16, and 6.06%, respectively. Laser-cut stents were associated with a significantly higher rate of successful deployment (p = 0.003) and significantly lower rate of periprocedural intracranial hemorrhage (p = 0.048). Braided stents were associated with a significantly lower rate of permanent morbidity (p = 0.015).Conclusion: SAC of IAs using laser-cut stents or braided stents was effective and safe. Rates of thromboembolic events, stent stenosis, mortality, and recanalization were comparable between the stent types. Braided stents were associated with lower permanent morbidity while laser-cut stents were associated with more favorable rates of successful deployment and periprocedural intracranial hemorrhage.

2015 ◽  
Vol 21 (3) ◽  
pp. 332-336 ◽  
Author(s):  
Jean-Christophe Gentric ◽  
Joelle Brisson ◽  
André Lima Batista ◽  
Jimmy Ghostine ◽  
Jean Raymond ◽  
...  

Background and purpose We aimed to determine the safety of intra-arterial Abciximab injection in the management of thromboembolic complications during endovascular treatment of ruptured cerebral aneurysms. Methods In a monocentric consecutive series of endovascular treatment of 783 ruptured aneurysms, 42 (5.3%) patients received Abciximab after the aneurysm was secured. Bleeding complications were registered and dichotomized as follows: new intracranial hemorrhage and peripheral bleeding. For each patient, World Federation of Neurosurgery (WFNS) subarachnoid hemorrhage (SAH) grade, shunting, and clinical outcomes in the post-operative period and at 3–6 months were recorded. Results SAH WFNS grades were as follows: grade I n = 14, grade II n = 10, grade III n = 11, grade IV n = 4, grade V n = 3. Ten patients had intracranial hematoma additionally to the SAH prior to embolization. Four patients (9.5%) presented more blood on the post-embolization CT but only one suffered a new clinically relevant intracranial hemorrhage. Two patients (4.8%) experienced significant peripheral bleeding but none were associated with long-term disabilities. Fourteen patients had a shunt installed less than 24 h prior to Abciximab injection and one less than 48 h later. At 3–6-month follow-up, 31 patients (74%) achieved a modified Rankin Scale score (mRS) of 2 or less, six patients (14%) had a mRS of 3–5, three were dead (7%), and two were lost at follow-up. Conclusion When the aneurysm is secured, intra-arterial Abciximab injection is a low complication rate treatment modality for thromboembolic events during embolization of cerebral ruptured aneurysm.


2020 ◽  
Author(s):  
Xintong Zhao ◽  
Jiaqiang Liu ◽  
Huifang Wang ◽  
Zihuan Zhang ◽  
Zhenbao Li

Abstract Purpose Single coiling may be the optimal strategy for ruptured aneurysms. But assisted techniques may be needed in some aneurysms. The authors report their experience of double microcatheter technique in the treatment of ruptured aneurysms in anterior cerebral circulation. Methods Between 2012 and 2018, 82 patients with ruptured aneurysms in anterior cerebral circulation were treated with double microcatheter technique. The clinical records, angiographic results, procedure-related complications were reviewed. Clinical and angiographic follow-up was performed. Results Completely occlusion, neck remnant and partial occlusion were achieved in 56.6%, 36.1% and 7.2% in the whole procedures, respectively. The overall rate of morbidity was 8.5% (7/82). The rate of permanent morbidity was 3.7% (3/82). Three patients (3.7%) died before discharge. There was no procedure-related mortality. The favorable outcomes were obtained in 75.6% (62/82) of the whole patients at discharge. High Hunt-Hess grade and suffering from craniotomy or EVD were risk factors for clinical outcomes at discharge. Sixty-eight patients received clinical follow-up at a mean interval of 15.75±12.71 months. Favorable outcomes were obtained in 61 (89.7%) patients. Angiographic follow-up was performed in 44 patients at an average of 13.16±13.12 months. The recurrence rate is 34.1%. Seven of them (15.9%) received retreatment. Conclusion Double microcatheter technique is a safe and effective method for treatment of ruptured aneurysms in anterior cerebral aneurysms with low morbidity. Recurrence remains a problem. Patients should be followed up regularly.


2009 ◽  
Vol 15 (1) ◽  
pp. 29-36 ◽  
Author(s):  
D.H. Lee ◽  
A. Arat ◽  
H. Morsi ◽  
L-D. Jou ◽  
M.E. Mawad

We present our initial experience of concentric-filling technique using MicruSphere 3D coils (Micrus Endovascular, San Jose, CA) in the treatment of intracranial aneurysms. 149 intracranial saccular aneurysms in 142 consecutive patients (mean age 56.6 ± 12.7, ruptured in 54 (36.2%)) were treated with the concentric-filling technique. The mean aneurysm volume was 169.0 ± 363.0 mm3. Neck remodeling technique was used in 120 (80.5%). Procedure-related problems were recorded. Initial embolization results were evaluated, and the coil packing density was calculated. Clinical and angiographic follow-ups were performed after six months. Any changes in embolization status were classified as ‘improved’, ‘unchanged’, or ‘worse’. The overall packing density was 40.1% (range 10.5–90.9%). The permanent morbidity and mortality rates were 4.0% and 1.3%, respectively. The initial Raymond and Roy classification results were class 1 in 37 aneurysms (24.8%), class 2 in 50 (33.6%), and class 3 in 62 (41.6%). On the mean follow-up examination of 8.2 months in 103 patients (72.5%), there were one transient ischemic attack, one minor stroke, and one instance of rebleeding. Angiographic follow-up in 101 aneurysms (67.8%) showed the change in embolization status as ‘improved’ in 42 aneurysms (41.6%), ‘unchanged’ in 42 (41.6%), and ‘worse’ in 17 (recanalisation rate, 16.8%). The concentric-filling technique using Micrusphere 3D coils was effective in achieving high packing density which in turn resulted in stable embolization in the majority of the aneurysms. Longer follow-up is warranted to determine the durability of these results.


Author(s):  
Ehsan Dowlati ◽  
Kory B. Dylan Pasko ◽  
Jiaqi Liu ◽  
Charles A. Miller ◽  
Daniel R. Felbaum ◽  
...  

In-stent stenosis is a feared complication of flow diversion treatment for cerebral aneurysms. We present 2 cases of patients treated with pipeline flow diversion for unruptured cerebral aneurysms. Initial perioperative dual antiplatelet therapy (DAPT) consisted of standard aspirin plus clopidogrel. At 6-month follow-up cerebral angiography, the patients were noted to have developed significant in-stent stenosis (63% and 53%). The patients were treated with cilostazol and clopidogrel for at least 6 months. Subsequent angiography at 1-year post-treatment showed significant improvement of the in-stent stenosis from 63% to 34% and 53% to 21%. The role of cilostazol as treatment of intracranial in-stent stenosis has not been previously described. Cilostazol’s vasodilatory effect and suppression of vascular smooth muscle proliferation provides ideal benefits in this setting. Cilostazol plus clopidogrel may be a safe and effective alternative to standard DAPT for treatment of in-stent stenosis following flow diversion and warrants further consideration and investigation.


2014 ◽  
Vol 120 (5) ◽  
pp. 1158-1171 ◽  
Author(s):  
Naci Kocer ◽  
Civan Islak ◽  
Osman Kizilkilic ◽  
Burak Kocak ◽  
Muzaffer Saglam ◽  
...  

Object Flow diverter (FD) stents are relatively new and important devices in the treatment of cerebral aneurysms. The Flow Re-Direction Endoluminal Device has been recently released for clinical use. The authors' aim in this paper is to report their initial single-center FRED experience with short-term results. Methods Between February 2012 and May 2013, 33 patients with 37 aneurysms (35 unruptured and 2 previously ruptured aneurysms) were treated with the FRED. Clinical and radiological data of the patients were retrospectively reviewed. Results In all patients only 1 device was used without any additional device or material, such as a stent or coil. All procedures were successfully performed. The procedural complication rate was 3% (1 of 33). Thirty patients underwent clinical and radiological follow-up. During the follow-up period, changes in stent morphology, such as “fish mouth” and “foreshortening” phenomena, occurred in 5 patients. The mortality and permanent morbidity rates were 0%. The complete occlusion rates were 32% (6 of 19) at 0–1 month, 67% (8 of 12) at 2–3 months, 80% (4 of 5) at 4–6 months, and 100% (8 of 8) at 7–12 months. The rates for some aneurysms were assessed at more than one time point. Conclusions The FRED has an ability to serve neurointerventionalists in the treatment of cerebral aneurysms with its different technical advantages. The occlusion rates with FRED are similar to those with other FD devices. However, these short-term results need to be confirmed with mid- and long-term follow-up results of multicenter large series.


2014 ◽  
Vol 120 (4) ◽  
pp. 945-954 ◽  
Author(s):  
Stephen J. Monteith ◽  
Asterios Tsimpas ◽  
Aaron S. Dumont ◽  
Stavropoula Tjoumakaris ◽  
L. Fernando Gonzalez ◽  
...  

Object Despite advances in surgical and endovascular techniques, fusiform aneurysms remain a therapeutic challenge. Introduction of flow-diverting stents has revolutionized the treatment of aneurysms with wide necks and of complex morphology. The authors report their experience with the endovascular treatment of fusiform aneurysms using the Pipeline Embolization Device. Methods A retrospective review of 146 patients with cerebral aneurysms treated with the Pipeline Embolization Device between June 2011 and January 2013 was performed. Twenty-four patients were identified as having fusiform aneurysms. Twenty-four aneurysms in these 24 patients were treated. The mean patient age was 59 years. There were 9 men and 15 women. Angiographic and clinical data (including the modified Rankin Scale [mRS] score) were recorded at the time of treatment and at follow-up. The aneurysms were located in the internal carotid artery in 8 patients (33.3%), middle cerebral artery in 8 patients (33.3%), anterior cerebral artery in 1 patient (4%), and vertebrobasilar circulation in 7 patients (29%). The aneurysms were smaller than 10 mm in 3 patients, 10–25 mm in 16 patients, and larger than 25 mm in 5 patients. The mean largest dimension diameter was 18 mm. Results Stent deployment was successful in all cases. The minor procedural morbidity was 4% (1 case). Morbidity and mortality related to aneurysm treatment were 4.2% and 4.2%, respectively. The mean mRS scores preoperatively and at clinical follow-up (median 6.0 months, mean 6.9 months) were 0.71 and 1.2, respectively (91.7% presented with an mRS score of 2 or better, and 79.2% had an mRS score of 2 or better at the 6.0-month follow-up). At clinical follow-up, 82.6% of patients were stable or had improved, 13.0% worsened, and 4.2% had died. Twenty-two (91.7%) of 24 patients had follow-up angiography available (mean follow-up time 6.3 months); 59% had excellent angiographic results (> 95% or complete occlusion), 31.8% had complete aneurysm occlusion, 27.3% had greater than 95% aneurysm occlusion, 18.2% had a moderate decrease in size (50%–95%), 4.5% had a minimal decrease in size (< 50%), 13.6% had not changed, and 4.5% had an increase in size. Conclusions This series demonstrates that endovascular treatment of fusiform cerebral aneurysms with flow diversion was a safe and effective treatment. Procedural complications were low. Long-term morbidity and mortality rates were acceptable given the complex nature of these lesions.


Neurosurgery ◽  
2007 ◽  
Vol 61 (3) ◽  
pp. 460-469 ◽  
Author(s):  
Alessandra Biondi ◽  
Vallabh Janardhan ◽  
Jeffrey M. Katz ◽  
Kimberly Salvaggio ◽  
Howard A. Riina ◽  
...  

Abstract OBJECTIVE To evaluate the midterm results of intracranial stent-assisted coil embolization in the treatment of wide-necked cerebral aneurysms and to assess the efficacy of various strategies used in stent deployment. METHODS A retrospective study of 42 patients with 46 wide-necked cerebral aneurysms enrolled in a prospective single-center registry of patients treated with a Neuroform stent (Boston Scientific/Target, Fremont, CA), a flexible self-expanding nitinol stent, was performed. Twenty-seven of 46 aneurysms were unruptured aneurysms, 14 were recanalized aneurysms, and five were acutely ruptured. Thirty-nine aneurysms were located in the anterior and seven in the posterior circulation. Mean aneurysm size was 9.8 mm. Stenting before coiling was performed in 13 of 45 aneurysms (29%), coiling before stenting in 27 of 45 aneurysms (60%), and stenting alone in five of 45 aneurysms (11%). The balloon remodeling technique for coiling before stenting was performed in 77% of patients. Angiographic and clinical follow up was available in 31 patients with 33 aneurysms and ranged from 3 to 24 months. RESULTS Neuroform stenting was attempted in 46 wide-necked aneurysms (42 patients). Forty-nine stent sessions were performed, including three poststent retreatments. In 46 of 49 sessions (94%), successful deployment of 47 stents for 45 aneurysms was obtained. In 40 aneurysms treated with stent-assisted coiling, angiographic results showed 14 (35%) aneurysm occlusions, 18 (45%) neck remnants, and eight (20%) residual aneurysms. In five recanalized aneurysms treated with stenting alone, no changes were observed in four (80%) aneurysms and one (20%) neck remnant reduced in size. At angiographic follow-up in 30 aneurysms treated with stent-assisted coiling, there were 17 (57%) aneurysm occlusions, seven (23%) neck remnants, and six (20%) residual aneurysms. In three recanalized aneurysms treated with stent alone, two (67%) neck remnants remained unchanged and one (33%) neck remnant decreased in size. Procedural morbidity was observed in two of 42 patients (4.8%) and one patient died. On clinical follow-up, the modified Rankin Scale score was 0 in 27 patients (87%), 1 in three patients (10%), and 2 (3%) in one patient. No aneurysm bled during the follow-up period. CONCLUSION These results indicate that Neuroform stent-assisted coil embolization is a safe and effective technique in the treatment of wide-necked cerebral aneurysms. Further studies are needed to evaluate the long-term durability of stent-assisted aneurysm occlusion and tolerance to the stent.


2017 ◽  
Vol 10 (3) ◽  
pp. 297-300 ◽  
Author(s):  
Cameron M McDougall ◽  
Khurshid Khan ◽  
Maher Saqqur ◽  
Andrew Jack ◽  
Jeremy Rempel ◽  
...  

Background and purposeFlow diversion is a relatively new strategy used to treat complex cerebral aneurysms. The optimal method for radiographic follow-up of patients treated with flow diverters has not been established. The rate and clinical implications of in-stent stenosis for these devices is unclear. We evaluate the use of transcranial Doppler ultrasound (TCD) for follow-up of in-stent stenosis.Materials and methodsWe analyzed 28 patients treated with the Pipeline embolization device (PED) over the course of 42 months from January 2009 to June 2012. Standard conventional cerebral angiograms were performed in all patients. TCD studies were available in 23 patients.ResultsAngiographic and TCD results were compared and found to correlate well.ConclusionsTCD is a potentially useful adjunct for evaluating in-stent stenosis after flow diversion.


2020 ◽  
pp. 159101992093204 ◽  
Author(s):  
Tom De Beule ◽  
T Boulanger ◽  
S Heye ◽  
WJ van Rooij ◽  
WH van Zwam ◽  
...  

Background and purpose Flow diverters are increasingly used to treat intracranial aneurysms. We report the safety and efficacy of the p64 flow diverter, a resheathable and detachable device for intracranial aneurysms. Materials and methods We retrospectively reviewed 108 patients with 109 aneurysms treated with the p64 between March 2014 and July 2019. There were 87 women and 21 men, mean age 57 years. Of 109 aneurysms, 74 were discovered incidentally, 12 were symptomatic, 18 were previously treated, and five were ruptured dissection aneurysms. A total of 10 aneurysms were located in the posterior circulation. The mean aneurysm or remnant size was 8.1 mm. Results Hemorrhage by perforation with the distal guidewire occurred in two patients with permanent neurological deficits in one. In one patient, acute in-stent occlusion caused infarction with a permanent deficit. Permanent morbidity was 1.9% (2 of 108, 95%CI 0.1–6.9%); there was no mortality. During follow-up, three in-stent occlusions occurred, all asymptomatic. There were no delayed hemorrhagic complications. At six months, 77 of 96 aneurysms (80.2%) were completely occluded, and at last follow-up, this increased to 93 of 96 aneurysms (96.9%). In-stent stenosis at any degree occurred in 11 patients, progressing to asymptomatic complete occlusion in one. In the other patients, stenosis resolved or improved at further follow-up. Conclusion The p64 offers an effective and safe treatment option. Aneurysm occlusion rate was 97% at last follow-up, mostly achieved with a single device. There were no delayed hemorrhagic complications. Delayed in-stent stenosis infrequently progresses to occlusion but remains a matter of concern.


Sign in / Sign up

Export Citation Format

Share Document