scholarly journals Diurnal Body Temperature and Rate of Passage of Loggers in Lions

Animals ◽  
2020 ◽  
Vol 10 (8) ◽  
pp. 1388
Author(s):  
Ted Friend ◽  
Giulia Corsini ◽  
Vincent Manero ◽  
Raffaella Cocco

The documentation of diurnal patterns in body temperature in lions could be important because disruption of circadian patterns can be a useful measure of distress. This study quantified changes in body temperature of seven African lions (Panthera leo) at 5 min intervals during cold conditions from noon until the ingested body temperature loggers were expelled the next day. Thirteen loggers were fed to 11 lions during their daily noon feeding, while ambient temperatures were also recorded using six data loggers. The lions had continuous access to their dens and exercise pens during the day but were restricted to their heavily bedded dens that also contained a heat lamp from 23:00 until 08:00 the next day. Body temperatures averaged 37.95 ± 0.42 °C at 15:50, and 36.81 ± 0.17 °C at 06:50 the next day, 30 min before the first loggers passed from a lion, and were significantly different (t-test, t = 8.09, df = 6, p < 0.0003). The mean duration for the time of passage was 22 ± 2.69 (h ± SD), so future studies using the noninvasive feeding of temperature loggers need to consider that time frame.

1999 ◽  
Vol 77 (9) ◽  
pp. 1348-1357 ◽  
Author(s):  
Jacqueline D Litzgus ◽  
Jon P Costanzo ◽  
Ronald J Brooks ◽  
Richard E Lee, Jr.

Using mark-recapture techniques, temperature-sensitive radio transmitters, and miniature temperature data loggers we investigated the hibernation ecology of northern temperate zone spotted turtles (Clemmys guttata) in Georgian Bay, Ontario, over 4 winters (1993-1997). We observed 18 hibernacula that were occupied by 34 turtles; 11 hibernacula were apparently occupied by single turtles, and 7 were used communally by up to 9 individuals. Hibernacula were located in swamps and were of 2 types: sphagnum moss hummock (n = 15) and rock cavern (n = 3). Almost half of the individuals (16 of 34) used the same hibernaculum in at least 2 winters. Turtles entered hibernacula between mid-September and October, when their body temperature was between 12 and 16°C, and exited them in mid to late April, when ambient temperatures ranged between 1 and 5°C. A waterproof temperature data logger attached to a turtle indicated that this turtle was protected from freezing in a thermally stable hibernaculum (body temperature range 0.3-3.9°C) despite highly variable (a 37°C change over 5 days) and low air temperatures (minimum -35°C). Loss of body mass (2%) during hibernation was not significant. We observed no mortality within hibernacula over the 4 winters; however, 3 turtles were destroyed by predators near the hibernacula. These data provide insight into the role of climate in limiting the northern distribution of this species.


2010 ◽  
Vol 90 (3) ◽  
pp. 321-330 ◽  
Author(s):  
T D Knezacek ◽  
A A Olkowski ◽  
P J Kettlewell ◽  
M A Mitchell ◽  
H L Classen

Temperature conditions inside commercial trailers transporting market-age broilers during four winter journeys were measured, and changes in the rectal and core body temperature of birds were quantified. Pre-selected modules were equipped with data loggers recording temperature every 72 s. Rectal temperatures were taken from eight birds in each of four modules immediately before and after each trip, and two or three birds, with temperature recording implants, were placed in each of two selected modules. Temperature heterogeneity was found among modules on all loads with average crate temperatures ranging from 10.9 to 30.7, 8.9 to 28.1, 2.5 to 26.1 and -0.7 to 16.5°C for transportation times of 191, 193, 178 and 18 min and ambient temperatures of -7.1, -27.1, -28.2 and -18.4°C, respectively. Wet birds, condensation and frost provided evidence for moisture accumulation during transportation. Body temperature recordings indicated the potential for the development of both hypothermia and hyperthermia, showing that cold stress can occur near air inlets and heat stress in poorly ventilated areas. Passive ventilation inside trailers resulted in crate temperatures 17.7 to 55.2°C above outside temperature. Mortality ranged from 0.7 to 1.4% but several deaths occurred during lairage, prior to processing. A heterogeneous distribution of airflow resulted in undesirable temperate and humidity conditions for some birds. Key words: Broiler, transportation, temperature gradient, mortality, cold weather


2021 ◽  
pp. 1-6
Author(s):  
Anand K. Bery ◽  
Jayson Lee Azzi ◽  
Andre Le ◽  
Naomi S. Spitale ◽  
Judith Leech ◽  
...  

BACKGROUND: Obstructive sleep apnea (OSA) has been linked to vestibular dysfunction, but no prior studies have investigated the relationship between Persistent Postural Perceptual Dizziness (PPPD), a common cause of chronic dizziness, and OSA. OBJECTIVE AND METHODS: We determined the frequency of OSA in an uncontrolled group of PPPD patients from a tertiary dizziness clinic based on polysomnogram (PSG). We then assessed the sensitivity and specificity of common OSA questionnaires in this population. RESULTS: Twenty-five patients with PPPD underwent PSG (mean age 47, 60% female, mean BMI 29.5). A majority, or 56%, of patients were diagnosed with OSA, and in most, the OSA was severe. OSA patients were older (56 years versus 40 years, p = 0.0006) and had higher BMI (32 versus 26, p = 0.0078), but there was no clear gender bias (56% versus 64% female, p = 1.00). The mean sensitivity and specificity of the STOP BANG questionnaire for detecting OSA was 86% and 55%, respectively. Sensitivity and specificity of the Berlin Questionnaire was 79% and 45%, respectively. CONCLUSIONS: The prevalence of OSA was much higher in our small PPPD group than in the general population. Screening questionnaires appear to demonstrate good sensitivity to detect PPPD patients at risk of OSA in this small study. Future studies should confirm these findings and determine whether treatment of OSA improves symptoms in PPPD.


2020 ◽  
Vol 4 (02) ◽  
pp. 079-085
Author(s):  
Muralidhar Kanchi ◽  
Priya Nair ◽  
Rudresh Manjunath ◽  
Kumar Belani

Abstract Background Perioperative hypothermia is not uncommon in surgical patients due to anesthetic-induced inhibition of thermoregulatory mechanisms and exposure of patients to cold environment in the operating rooms. Core temperature reduction up to 35°C is often seen in off-pump coronary artery bypass graft (OP-CABG) surgery. Anesthetic depth can be monitored by using bispectral (BIS) index. The present study was performed to evaluate the influence of mild hypothermia on the anesthetic depth using BIS monitoring and correlation of BIS with end-tidal anesthetic concentration at varying temperatures during OP-CABG. Materials and Methods In a prospective observational study design in a tertiary care teaching hospital, patients who underwent elective OP-CABG under endotracheal general anesthesia, were included in the study. Standard technique of anesthesia was followed. BIS, nasopharyngeal temperature, and end-tidal anesthetic concentration of inhaled isoflurane was recorded every 10 minutes. The BIS was adjusted to between 45 and 50 during surgery. Results There were 40 patients who underwent OP-CABG during the study period. The mean age was 51.2 ± 8.7 years, mean body mass index 29.8 ± 2.2, and mean left ventricular ejection fraction was 55.4 ± 4.2%. Anesthetic requirement as guided by BIS between 45 and 50 correlated linearly with core body temperature (r = 0.999; p < 0.001). The mean decrease in the body temperature at the end of 300 minutes was 2.2°C with a mean decrease in end-tidal anesthetic concentration of 0.29%. The reduction in end-tidal anesthetic concentration per degree decrease in temperature was 0.13%. None of the patients reported intraoperative recall. Conclusion In this study, BIS monitoring was used to guide the delivery concentration of inhaled anesthetic using a targeted range of 45 to 50. BIS monitoring allowed the appropriate reduction of anesthetic dosing requirements in patients undergoing OP-CABG without risk of awareness. There was a significant reduction in anesthetic requirements associated with reduction of core temperature. The routine use of BIS is recommended in OP-CABG to titrate anesthetic requirement during occurrence of hypothermia and facilitate fast-track anesthesia in this patient population.


1975 ◽  
Vol 53 (6) ◽  
pp. 679-685 ◽  
Author(s):  
J. B. Holter ◽  
W. E. Urban Jr. ◽  
H. H. Hayes ◽  
H. Silver ◽  
H. R. Skutt

Six adult white-tailed deer (Odocoileus virginianus borealis) were exposed to 165 periods of 12 consecutive hours of controlled constant ambient temperature in an indirect respiration calorimeter. Temperatures among periods varied from 38 to 0 (summer) or to −20C (fall, winter, spring). Traits measured were energy expenditure (metabolic rate), proportion of time spent standing, heart rate, and body temperature, the latter two using telemetry. The deer used body posture extensively as a means of maintaining body energy equilibrium. Energy expenditure was increased at low ambient temperature to combat cold and to maintain relatively constant body temperature. Changes in heart rate paralleled changes in energy expenditure. In a limited number of comparisons, slight wind chill was combatted through behavioral means with no effect on energy expenditure. The reaction of deer to varying ambient temperatures was not the same in all seasons of the year.


1923 ◽  
Vol 22 (2) ◽  
pp. 123-155 ◽  
Author(s):  
J. Graham Forbes

1. The bacterial content of the air of the Underground Railways, when the average of all results of the bacteriological investigations is taken, does not numerically compare unfavourably with the outside air of London.2. The ratio of the number of organisms growing at room temperature appears to be about 14 for railway air to 10 outside air. For those growing at body temperature the ratio is considerably higher, namely 2 to 1 respectively. The mean per litre, for room temperature organisms, is about 9 in railway air, 6·3 in the outside air; for body temperature organisms 4·6 for railway air, 2·2 for outside air.3. The bacterial content of platform air, except on the City and South London Railway, would appear to be higher than that of carriage air; the total mean for platform air being 52 and for carriage air 42·8 organisms per 5 litres, or a ratio of 16·4 and 13·5 respectively to 10 of the open air. The higher proportion in platform air is generally speaking to be accounted for by the greater amount of draught and dust disturbance.4. The ratios of the total bacterial content of railway carriage air and carriage and platform air on the six lines to open air are estimated in the following proportions:


1964 ◽  
Vol 46 (4) ◽  
pp. 597-607 ◽  
Author(s):  
Jan Erik Kihlström ◽  
Otto Hornstein

ABSTRACT Recently some physiological characteristics of a sex cycle in male animals have been demonstrated. However, nothing is known at present about any morphological expressions of this cycle, and particularly about any rhythmical variation in exfoliation of cells comparable with that of the vaginal mucous membrane. On the assumption that such a rhythm may occur in the male urethra, the exfoliation of cells in this organ has been studied by taking daily smears. Cyclically varying frequencies of four different types of exfoliated cells, mainly in an immature stage, were demonstrated. Only a fifth type of cells, characterized by cornification and nuclear degeneration, is not subjected to such rhythmical variation. The mean duration of these cycles is about four days. Simultaneous investigations on the seminal volume and body temperature showed some relation to the cycle of cell desquamation. The results give additional evidence for the existence of a male sex cycle, probably with a hormonal background.


2015 ◽  
Vol 28 (17) ◽  
pp. 6823-6840 ◽  
Author(s):  
Froila M. Palmeiro ◽  
David Barriopedro ◽  
Ricardo García-Herrera ◽  
Natalia Calvo

Abstract Sudden stratospheric warmings (SSWs) are characterized by a pronounced increase of the stratospheric polar temperature during the winter season. Different definitions have been used in the literature to diagnose the occurrence of SSWs, yielding discrepancies in the detected events. The aim of this paper is to compare the SSW climatologies obtained by different methods using reanalysis data. The occurrences of Northern Hemisphere SSWs during the extended-winter season and the 1958–2014 period have been identified for a suite of eight representative definitions and three different reanalyses. Overall, and despite the differences in the number and exact dates of occurrence of SSWs, the main climatological signatures of SSWs are not sensitive to the considered reanalysis. The mean frequency of SSWs is 6.7 events decade−1, but it ranges from 4 to 10 events, depending on the method. The seasonal cycle of events is statistically indistinguishable across definitions, with a common peak in January. However, the multidecadal variability is method dependent, with only two definitions displaying minimum frequencies in the 1990s. An analysis of the mean signatures of SSWs in the stratosphere revealed negligible differences among methods compared to the large case-to-case variability within a given definition. The stronger and more coherent tropospheric signals before and after SSWs are associated with major events, which are detected by most methods. The tropospheric signals of minor SSWs are less robust, representing the largest source of discrepancy across definitions. Therefore, to obtain robust results, future studies on stratosphere–troposphere coupling should aim to minimize the detection of minor warmings.


Sign in / Sign up

Export Citation Format

Share Document