scholarly journals True 2-D Resistivity Imaging from Vertical Electrical Soundings to Support More Sustainable Rural Water Supply Borehole Siting in Malawi

2021 ◽  
Vol 11 (3) ◽  
pp. 1162
Author(s):  
Romain Leborgne ◽  
Michael O. Rivett ◽  
Gift J. Wanangwa ◽  
Philippe Sentenac ◽  
Robert M. Kalin

To improve borehole siting for rural water supply, an advanced resistivity method was adapted for developing country use and demonstrated in Malawi. The method was designed to be low cost, developing-country accessible, efficient. It allows single or multiple operators to acquire the multiple vertical electrical soundings (VESs) required that are inverted together in 2-D, to give a true cross-section of subsurface resistivity. Application at four sites generated true cross-sections of subsurface resistivity to around 100 m depth relevant to groundwater-resource investigation. A wide range of (hydro)geological features was identified, including fractured/weathered basement, gneiss domes, well-developed fault zones and several types of deltaic deposits. Imaging performance appears comparable to that of 2-D surface ERT (electrical resistivity tomography) that uses more expensive equipment, often unaffordable in developing countries. Based on the subsurface configurations determined and hydrogeological conceptualisation subsequently undertaken, the local aquifer potential could be evaluated, thereby providing a decision-making basis for future borehole siting at the sites surveyed. The technology is far superior to conventional 1-D VES, electromagnetic profiling or magnetic profiling currently used for borehole siting in Malawi. Technology adoption currently under consideration nationally would make use of existing VES capacity and permit much improved targeting of aquifer resource, more sustainable siting of boreholes and greater future resilience of Malawi’s rural water-supply infrastructure.

Waterlines ◽  
1982 ◽  
Vol 1 (2) ◽  
pp. 28-31
Author(s):  
Adrian Clark

1990 ◽  
Vol 21 (3) ◽  
pp. 205-216 ◽  
Author(s):  
A. Idowu Olayinka

Ground electromagnetic profiling, using a Geonics EM34-3 instrument, has been employed to identify areas of high conductivity in a Precambrian basement complex terrain of Nigeria. Field examples, conducted as part of a rural water supply programme, are presented. They indicate that the apparent conductivities are generally lower than about 60 mmho m−1. Subsequent borehole drilling suggests a good correlation between high EM34 anomalies, deep weathering and high well yield (> 1 1 s−1). On the other hand, boreholes sited on conductivity lows penetrated a thinner regolith with relatively lower yields.


Water Policy ◽  
2014 ◽  
Vol 16 (4) ◽  
pp. 650-668 ◽  
Author(s):  
Satyapriya Rout

The paper reports the main findings of a study, designed to develop a better understanding of institutional variations in working with the demand responsive approach (DRA) in rural water supply in the state of Odisha in India. Data for the paper were collected from twelve village communities, where water is being supplied either through their community based institution or through the local government institution of the Gram Panchayat. The findings suggest that the two types of institutions performed differently in implementing the DRA. It depicted that the DRA under the broader rubric of institutional reforms in the water sector has failed to address the question of social inequality, and rather had reinforced and extended the already existing inequity of Indian society to access to safe and secure drinking water in rural areas. The study highlights that participation, cost recovery, full operation and management transfer may be an efficient proposition, but not sustainable in the long run without proper investment in institution building and support from the state, especially in provisioning of basic services like drinking water to rural poor.


Sign in / Sign up

Export Citation Format

Share Document