scholarly journals Seismic Performance of Grille-Type Steel Plate Concrete Composite Walls with Application in a Super-High-Rise Building

2021 ◽  
Vol 11 (16) ◽  
pp. 7580
Author(s):  
Yang Liu ◽  
Hao Wu ◽  
Qiao Yu ◽  
Yun Li ◽  
Jianan Li ◽  
...  

The grille-type steel plate concrete composite wall (GSPCW) is an innovative shear wall system that mainly consists of steel faceplates, steel tie plates and infilled concrete. Compared to traditional steel plate concrete composite shear walls, the advantages of GSPCW walls include: (1) relatively high lateral and buckling resistance; and (2) simple structural measures for convenient construction and implementation. This paper presents the results of extensive numerical investigations regarding GSPCW systems, examining both GSPCW wall components and their application in a super-high-rise building as a case study. First, typical GSPCW wall models are established using DIANA software, and the numerical models are validated on the basis of comparison with results from previously reported experimental tests. The verified models are further used to perform parametric analyses with the aim of further understanding the effects of various design parameters on the seismic performance of GSPCW systems, including steel ratio, axial load ratio, height-to-width ratio, aspect ratio of the grille steel plate, and concrete compressive strength. Second, a super-high-rise building was selected for application to perform a case study of a GSPCW system. The seismic performance of the tall building in the case study was comparatively evaluated on the basis of both nonlinear time history analysis and modal pushover analysis (MPA), and the results from both of these methods validated the use of GSPCW is an efficient structural wall system appropriate for use in super-high-rise buildings. Finally, a simple economic assessment of the GSPCW building was performed, and the results were compared with those obtained for conventional reinforced concrete wall buildings.

2014 ◽  
Vol 580-583 ◽  
pp. 1551-1554
Author(s):  
Gen Tian Zhao ◽  
Xu Ting Kou

With the project case, the seismic performance of girder transfer floor member and the plate transfer floor member were discussed. Contrast calculation was carried out in girder transfer floor member and the plate transfer floor member with SATWE method to analyze its reasonable and unreasonable places. Based on overall structure calculation of a high rise building, the seismic design requirements for buildings applying thick transferring plate have been presented. The conclusion is that the seismic performance of girder transfer floor member is more advantageous and affordable, more convenient and more economical in ingredients.


1992 ◽  
Vol 11 (1) ◽  
pp. 19-23
Author(s):  
Belden Menkus

ce/papers ◽  
2017 ◽  
Vol 1 (2-3) ◽  
pp. 3181-3189 ◽  
Author(s):  
Abhishek Verma ◽  
Dipti Ranjan Sahoo

2010 ◽  
Vol 163-167 ◽  
pp. 1281-1285
Author(s):  
Bin Wang ◽  
Huan Jun Jiang ◽  
Jian Bao Li ◽  
Wen Sheng Lu ◽  
Xi Lin Lu

The reinforced concrete (RC) frame-tube structure considered in the study has two towers with lapping transfer columns. The lapping transfer columns, considering aesthetic requirement in elevation, lead to a complex vertical force transfer system. The large irregularity in elevation, according to Chinese code, necessitates a detailed study. A 1/15-scaled model of the high-rise building was tested on a shaking table to evaluate its seismic performance. The model was subjected to earthquake inputs representing frequent, basic, rare, and extremly rare earthquakes. The results of shaking table test in terms of the global and local responses as well as the dynamic properties are presented. The tests demonstrate that the designed structural system satisfies the pre-defined performance objectives and the lapping transfer columns have good seismic peformance. To better control seismic damages of the building, some suggestions for improving the design of this structure are also put forward at last.