Seismic Performance of Oblique Columns in High Rise Building

Author(s):  
Nikha Santhosh ◽  
Gayathri Krishna Kumar
2014 ◽  
Vol 580-583 ◽  
pp. 1551-1554
Author(s):  
Gen Tian Zhao ◽  
Xu Ting Kou

With the project case, the seismic performance of girder transfer floor member and the plate transfer floor member were discussed. Contrast calculation was carried out in girder transfer floor member and the plate transfer floor member with SATWE method to analyze its reasonable and unreasonable places. Based on overall structure calculation of a high rise building, the seismic design requirements for buildings applying thick transferring plate have been presented. The conclusion is that the seismic performance of girder transfer floor member is more advantageous and affordable, more convenient and more economical in ingredients.


2010 ◽  
Vol 163-167 ◽  
pp. 1281-1285
Author(s):  
Bin Wang ◽  
Huan Jun Jiang ◽  
Jian Bao Li ◽  
Wen Sheng Lu ◽  
Xi Lin Lu

The reinforced concrete (RC) frame-tube structure considered in the study has two towers with lapping transfer columns. The lapping transfer columns, considering aesthetic requirement in elevation, lead to a complex vertical force transfer system. The large irregularity in elevation, according to Chinese code, necessitates a detailed study. A 1/15-scaled model of the high-rise building was tested on a shaking table to evaluate its seismic performance. The model was subjected to earthquake inputs representing frequent, basic, rare, and extremly rare earthquakes. The results of shaking table test in terms of the global and local responses as well as the dynamic properties are presented. The tests demonstrate that the designed structural system satisfies the pre-defined performance objectives and the lapping transfer columns have good seismic peformance. To better control seismic damages of the building, some suggestions for improving the design of this structure are also put forward at last.


2021 ◽  
Vol 2021 ◽  
pp. 1-14
Author(s):  
Haotian Zhang ◽  
Fuju Li ◽  
Ji Tai ◽  
Jun Zhou

In the high intensity areas, the application of interlayer spacing technology can achieve the unity of quality and seismic performance of high-rise buildings with enlarged base and multiple tower layers. Through the comparison and analysis of the structural schemes of an enlarged base multiple tower-layer high-rise building, the ultimate seismic isolation scheme was adopted, and its seismic response and seismic performance were analyzed and studied. The results show that the overall seismic isolation effect of the story isolation technique is good, which can greatly reduce the seismic response, and is an effective means to improve the seismic safety of the structure. Considering the structural characteristics of the project, the improvement of the economy and the quality of the building, the use of story isolation technique in the enlarged base multiple tower-layer structure in the high-intensity region is an optimal scheme. Finally, several key technical issues such as the combined seismic isolation scheme of the enlarged base story isolation technique and the additional bending moment of the isolator and the tensile device of the isolator were discussed, which can provide some references for similar engineering practices.


2014 ◽  
Vol 584-586 ◽  
pp. 1841-1844
Author(s):  
Fang Fang Yang

Super high-rise building seismic design of complex shape is very important, can not be carried out according to the traditional design method. This paper gives a design principle based on behavior, it in the engineering design and more attention. Method based on behavior on the properties of reaction structures under earthquake is evaluated. High-rise buildings must be based on the method of state to confirm that the building to meet seismic performance.


2010 ◽  
Vol 163-167 ◽  
pp. 2203-2208
Author(s):  
De Jian Shen ◽  
Sen Qiu ◽  
Ling Song ◽  
Cong Bin Huang

In this paper, the effect of viscous damper on seismic performance of steel-concrete hybrid structure for high-rise building is analyzed. The result shows that viscous damper has little effect on dynamic properties of structure. The story lateral displacement, story drift rotation and damage of structure can be reduced effectively by viscous damper. The effect of the viscous damper on structure seismic performance is better with the increase of seismic intensity. Under the 7, 8 and 9 degree seismic seldom intensity, the story lateral displacement of the top floor decreases at 17.2%, 23.3%, 33.4% and the story drift rotation decreases at 20.8%, 27.2%, 44.7% respectively. The seismic analysis result may be referred by designer and researcher.


2015 ◽  
Vol 104 (1) ◽  
pp. 1-6
Author(s):  
Seiya Kimura ◽  
Yuichi Koitabashi ◽  
Masato Ishii ◽  
Shinichi Fuji

Sign in / Sign up

Export Citation Format

Share Document