scholarly journals Enhanced Fault Current-Limiting Circuit Design for a DC Fault in a Modular Multilevel Converter-Based High-Voltage Direct Current System

2019 ◽  
Vol 9 (8) ◽  
pp. 1661 ◽  
Author(s):  
Kaipei Liu ◽  
Qing Huai ◽  
Liang Qin ◽  
Shu Zhu ◽  
Xiaobing Liao ◽  
...  

The main weakness of the half-bridge modular multilevel converter-based high-voltage direct current (MMC-HVDC) system lies in its immature solution to extremely high current under direct current (DC) line fault. The development of the direct current circuit breaker (DCCB) remains constrained in terms of interruption capacity and operation speed. Therefore, it is essential to limit fault current in the MMC-HVDC system. An enhanced fault current-limiting circuit (EFCLC) is proposed on the basis of fault current study to restrict fault current under DC pole-to-pole fault. Specifically, the EFCLC consists of fault current-limiting inductance L F C L and energy dissipation resistance R F C L in parallel with surge arrestor. L F C L reduces the fault current rising speed, together with arm inductance and smoothing reactor. However, in contrast to arm inductance and smoothing reactor, L F C L will be bypassed via parallel-connected thyristors after blocking converter to prevent the effect on fault interruption speed. R F C L shares the stress on energy absorption device (metal oxide arrester) to facilitate fault interruption. The DCCB requirement in interruption capacity and breaking speed can be satisfied effortlessly through the EFCLC. The working principle and parameter determination of the EFCLC are presented in detail, and its effectiveness is verified by simulation in RT-LAB and MATLAB software platforms.

Author(s):  
Araitz Iturregi ◽  
Agurtzane Etxegarai ◽  
D. Marene Larruskain ◽  
Pablo Eguia ◽  
Oihane Abarrategui

Goi-tentsioko korronte zuzeneko (ingelesez, High Voltage Direct Current HVDC) garraio-sistemak gero eta garrantzitsuagoak dira sistema elektrikoan, onura ekonomiko eta teknikoak direla eta. Hala ere, akatsen bat gertatzen denean, korrontea eteteak oraindik ere erronka izaten jarraitzen du HVDC sareetan. Desiragarriak ez diren korronteak eteteko, korronte zuzeneko etengailuak erabil daitezke, baina horien gaitasuna mugatua da. Egoera hala izanik, akats-korronteen mugagailuak (ingelesez, Fault Current Limiter FCL) dira proposamenik egokiena akats-korronteak maneiagarriagoak diren balioetara txikitzeko; hartara, sistema elektrikoaren garraio-ahalmena handitu daiteke, ekipamendua aldatu beharrik gabe. Sarean aldez aurretik legokeen ekipamendua gai izango litzateke korronte berriak kudeatzeko eta sistema era eraginkorrean babesteko FCLen erabilpenaz. Artikulu honetan, FCL tresnen ezaugarri orokorrak eta sailkapena aurkezten dira. Ondoren, egoera solidoko FCLa erabili da maila anizkoitzeko bihurgailudun (ingelesez, Modular Multilevel Converter MMC) VSC-HVDC (ingelesez, Voltage Source Converter) sistema batean, eta horren jokaera azaltzen da simulazio bidez.


Energies ◽  
2018 ◽  
Vol 11 (8) ◽  
pp. 2102 ◽  
Author(s):  
Liang Xiao ◽  
Yan Li ◽  
Huangqing Xiao ◽  
Zheren Zhang ◽  
Zheng Xu

A method for electromechanical modeling of line commutated converter (LCC)-modular multilevel converter (MMC)-based hybrid multi-terminal High Voltage Direct Current Transmission (HVDC) systems for large-scale power system transient stability study is proposed. Firstly, the general idea of modeling the LCC-MMC hybrid multi-terminal HVDC system is presented, then the AC-side and DC-side models of the LCC/MMC are established. Different from the conventional first-order DC-side model of the MMC, an improved second-order DC-side model of the MMC is established. Besides considering the firing angle limit of the LCC, a sequential power flow algorithm is proposed for the initialization of LCC-MMC hybrid multi-terminal HVDC system. Lastly, simulations of small scale and large scale power systems embedded with a three-terminal LCC-MMC hybrid HVDC system are performed on the electromechanical simulation platform PSS/E. It is demonstrated that if the firing angle limit is not considered, the accuracy of the power flow solutions will be greatly affected. Steady state calculation and dynamic simulation show that the developed LCC-MMC hybrid MTDC model is accurate enough for electromechanical transient stability studies of large-scale AC/DC system.


Sign in / Sign up

Export Citation Format

Share Document