scholarly journals Comparative Assessment of Various Low-Dissipation Combined Models for Three-Terminal Heat Pump Systems

Entropy ◽  
2021 ◽  
Vol 23 (5) ◽  
pp. 513
Author(s):  
Zhexu Li ◽  
Haibo Cao ◽  
Hanxin Yang ◽  
Juncheng Guo

Thermally driven heat pump systems play important roles in the utilization of low-grade thermal energy. In order to evaluate and compare the performances of three different constructions of thermally driven heat pump and heat transformer, the low-dissipation assumption has been adopted to establish the irreversible thermodynamic models of them in the present paper. By means of the proposed models, the heating loads, the coefficients of performance (COPs) and the optimal relations between them for various constructions are derived and discussed. The performances of different constructions are numerically assessed. More importantly, according to the results obtained, the upper and lower bounds of the COP at maximum heating load for different constructions are generated and compared by the introduction of a parameter measuring the deviation from the reversible limit of the system. Accordingly, the optimal constructions for the low-dissipation three-terminal heat pump and heat transformer are determined within the frame of low-dissipation assumption, respectively. The optimal constructions in accord with previous research and engineering practices for various three-terminal devices are obtained, which confirms the compatibility between the low-dissipation model and endoreversible model and highlights the validity of the application of low-dissipation model for multi-terminal thermodynamic devices. The proposed models and the significant results obtained enrich the theoretical thermodynamic model of thermally driven heat pump systems and may provide some useful guidelines for the design and operation of realistic thermally driven heat pump systems.

Author(s):  
Noman Yousuf ◽  
Timothy Anderson ◽  
Roy Nates

Abstract Despite being identified nearly a century ago, the diffusion absorption refrigeration (DAR) cycle has received relatively little attention. One of the strongest attractions of the DAR cycle lies in the fact that it is thermally driven and does not require high value work. This makes it a prime candidate for harnessing low grade heat from solar collectors, or the waste heat from stationary generators, to produce cooling. However, to realize the benefits of the DAR cycle, there is a need to develop an improved understanding of how design parameters influence its performance. In this vein, this work developed a new parametric model that can be used to examine the performance of the DAR cycle for a range of operating conditions. The results showed that the cycle's performance was particularly sensitive to several factors: the rate of heat added and the temperature of the generator, the effectiveness of the gas and solution heat exchangers, the mass flowrate of the refrigerant and the type of the working fluid. It was shown that can deliver good performance at low generator temperatures if the refrigerant mass fraction in the strong solution is made as high as possible. Moreover, it was shown that a H2O-LiBr working pair could be useful for achieving cooling at low generator temperatures.


2020 ◽  
Vol 143 (1) ◽  
Author(s):  
Azzam Abu-Rayash ◽  
Ibrahim Dincer

Abstract This paper features the integration of two renewable energy sources, making a new trigeneration system for residential applications. The system is primarily powered by solar photovoltaic-thermal (PVT) along with geothermal energy. This trigeneration system consists of a ground source heat pump, solar system, high-grade and low-grade heat exchangers, a heat pump system, and a water storage tank (WST). The objective of this system is to provide the main commodities for residential use including domestic hot water (DHW), electricity, and space heating. The system is analyzed energetically and exergetically using thermodynamic-based concepts. The overall energy and exergy efficiencies of the proposed system are found to be 86.9% and 74.7%, respectively. In addition, the energy and exergy efficiencies of the PVT system are obtained to be 57.91% and 34.19%, respectively. The exergy destructions at the high-grade heat exchanger and the water storage tank add up to 36.9 kW, which makes up 80% of the total exergy destruction of the system. Additionally, parametric studies are conducted to evaluate the degree of impact that various important parameters have on the overall system performance.


Sign in / Sign up

Export Citation Format

Share Document