scholarly journals Techno-Economic Analysis of a Residential PV-Storage Model in a Distribution Network

Energies ◽  
2019 ◽  
Vol 12 (16) ◽  
pp. 3062 ◽  
Author(s):  
Xiong ◽  
Nour

The high penetration level of photovoltaic (PV) generation in distribution networks not only brings benefits like carbon savings, but also induces undesirable outcomes, like more harmonic components and voltage fluctuations. Driven by decreasing costs of energy storage, the focus of this paper is to investigate the feasibility of applying energy storage in the grid-connected PV system to mitigate its intermittency. Firstly, to appreciate the functionality of storage, a generic PV-battery-supercapacitor model was simulated in MATLAB/Simulink, and a flat load profile was obtained to enhance predictability from the network management point of view. However, the usage of supercapacitors at the residential level is limited, due to its high startup costs. Secondly, a detailed residential PV-battery model was implemented in the System Advisor Model (SAM) based on local data in Dubai. The optimal sizing of a battery system was determined by assessing two criteria: The number of excursions, and average target power, which are contradictory in optimization process. Statistical indicators show that a properly sized battery system can alleviate network fluctuations. The proposed sizing method can be also applied to other PV-storage systems. Finally, economic studies of PV-battery system demonstrated its competitiveness against standalone PV systems under appropriate tariff incentives.

Energies ◽  
2020 ◽  
Vol 13 (13) ◽  
pp. 3355 ◽  
Author(s):  
Jinkui He ◽  
Yongheng Yang ◽  
Dmitri Vinnikov

There is an increasing demand in integrating energy storage with photovoltaic (PV) systems to provide more smoothed power and enhance the grid-friendliness of solar PV systems. To integrate battery energy storage systems (BESS) to an utility-scale 1500 V PV system, one of the key design considerations is the basic architecture selection between DC- and AC-coupling. Hence, it is necessary to assess the reliability of the power conversion units, which are not only the key system components, but also represent the most reliability-critical parts, in order to ensure an efficient and reliable 1500 V PV-battery system. Thus, this paper investigates the BESS solutions of DC- and AC-coupled configurations for 1500 V PV systems with a comparative reliability analysis. The reliability analysis is carried out through a case study on a 160 kW/1500 V PV-system integrated DC- or AC-coupled BESS for PV power smoothing and ramp-rate regulation. In the analysis, all of the DC-DC and DC-AC power interfacing converters are taken into consideration along with component-, converter-, and system-level reliability evaluation. The results reveal that the reliability of the 1500 V PV inverter can be enhanced with the DC-coupled BESS, while seen from the system-level reliability (i.e., a PV-battery system), both of the DC- and AC-coupled BESSs will affect the overall system reliability, especially for the DC-coupled case. The findings can be added into the design phase of 1500 V PV systems in a way to further lower the cost of energy.


2012 ◽  
Vol 2012 ◽  
pp. 1-11
Author(s):  
Myo Htaik ◽  
Ryoichi Hara ◽  
Hiroyuki Kita

Most photovoltaic (PV) generation systems are connected with a utility grid and recognized as supplemental generation resources; but in some applications such as microgrid concept, a PV system works as a main resource. To improve the availability of PV systems, technological development for higher less output fluctuation in normal condition, higher fault tolerance in fault occurrence, and power demand and supply balancing in isolated condition are required. For these reasons, hybridization of a PV system and an energy storage system (ESS) would become an important technology in the future. This paper presented two kinds of circuit models, conventional “ac-connected PV-ESS,” and proposed “dc-connected PV-ESS” in which ESS is inserted at the dc-side of PV system. This paper also investigated dc-link voltage controlled by dc-dc converter of ESS in dc-connected PV-ESS and suitable control systems are also discussed normal, during fault occurrence and isolated operation.


Energies ◽  
2018 ◽  
Vol 11 (11) ◽  
pp. 3152 ◽  
Author(s):  
Huadian Xu ◽  
Jianhui Su ◽  
Ning Liu ◽  
Yong Shi

Conventional photovoltaic (PV) systems interfaced by grid-connected inverters fail to support the grid and participate in frequency regulation. Furthermore, reduced system inertia as a result of the integration of conventional PV systems may lead to an increased frequency deviation of the grid for contingencies. In this paper, a grid-supporting PV system, which can provide inertia and participate in frequency regulation through virtual synchronous generator (VSG) technology and an energy storage unit, is proposed. The function of supporting the grid is implemented in a practical PV system through using the presented control scheme and topology. Compared with the conventional PV system, the grid-supporting PV system, behaving as an inertial voltage source like synchronous generators, has the capability of participating in frequency regulation and providing inertia. Moreover, the proposed PV system can mitigate autonomously the power imbalance between generation and consumption, filter the PV power, and operate without the phase-locked loop after initial synchronization. Performance analysis is conducted and the stability constraint is theoretically formulated. The novel PV system is validated on a modified CIGRE benchmark under different cases, being compared with the conventional PV system. The verifications demonstrate the grid support functions of the proposed PV system.


Author(s):  
Zaid H. Ali ◽  
Ziyaad H. Saleh ◽  
Raid W. Daoud ◽  
Ahmed H. Ahmed

<p><span>This paper proposes a methodology for designing and operating a microgrid (MG) for the main campus of the Technical Institution Hawija. In this MG, a battery energy storage system (BESS), photovoltaic (PV) generation system, and controllable loads are included. Due to the high penetration of the PVs, over-voltage issues may occur in this MG. A novel operation strategy is considered by coordinating the BESS, PVs, and loads to prevent power outages and accomplish a secure operation of this MG. In this proposed approach, droop controllers have been implemented to provide the appropriate references for the PVs and BESS to maintain the voltage of the MG within a secure range. The generation of the PVs may be curtailed to guarantee the fidelity of the voltage. The intended simulations will be based on MATLAB/Simulink to show the efficacy of the intended design.</span></p><script type="text/javascript" src="https://cdnjs.cloudflare.com/ajax/libs/mathjax/2.7.0/MathJax.js?config=TeX-AMS-MML_HTMLorMML&amp;delayStartupUntil=configured"></script><script id="texAllTheThingsPageScript" type="text/javascript" src="chrome-extension://cbimabofgmfdkicghcadidpemeenbffn/js/pageScript.js"></script>


2013 ◽  
Vol 479-480 ◽  
pp. 590-594
Author(s):  
Wei Lin Hsieh ◽  
Chia Hung Lin ◽  
Chao Shun Chen ◽  
Cheng Ting Hsu ◽  
Chin Ying Ho ◽  
...  

The penetration level of a PV system is often limited due to the violation of voltage variation introduced by the large intermittent power generation. This paper discusses the use of an active power curtailment strategy to reduce PV power injection during peak solar irradiation to prevent voltage violation so that the PV penetration level of a distribution feeder can be increased to fully utilize solar energy. When using the proposed voltage control scheme for limiting PV power injection into the study distribution feeder during high solar irradiation periods, the total power generation and total energy delivered by the PV system over a 1-year period are determined according to the annual duration of solar irradiation. With the proposed voltage control to perform the partial generation rejection of PV systems, the optimal installation capacity of PV systems can be determined by maximizing the net present value of the system so that better cost effectiveness of the PV project and better utilization of solar energy can be obtained.


2020 ◽  
Vol 12 (15) ◽  
pp. 6154 ◽  
Author(s):  
Hui Wang ◽  
Jun Wang ◽  
Zailin Piao ◽  
Xiaofang Meng ◽  
Chao Sun ◽  
...  

High-penetration grid-connected photovoltaic (PV) systems can lead to reverse power flow, which can cause adverse effects, such as voltage over-limits and increased power loss, and affect the safety, reliability and economic operations of the distribution network. Reasonable energy storage optimization allocation and operation can effectively mitigate these disadvantages. In this paper, the optimal location, capacity and charge/discharge strategy of the energy storage system were simultaneously performed based on two objective functions that include voltage deviations and active power loss. The membership function and weighting method were used to combine the two objectives into a single objective. An energy storage optimization model for a distribution network considering PV and load power temporal changes was thus established, and the improved particle swarm optimization algorithm was utilized to solve the problem. Taking the Institute of Electrical and Electronic Engineers (IEEE)-33 bus system as an example, the optimal allocation and operation of the energy storage system was realized for the access of high penetration single-point and multi-point PV systems in the distribution network. The results of the power flow optimization in different scenarios were compared. The results show that using the proposed approach can improve the voltage quality, reduce the power loss, and reduce and smooth the transmission power of the upper-level grid.


Sign in / Sign up

Export Citation Format

Share Document