scholarly journals Design of an Active Damping System for Vibration Control of Wind Turbine Towers

2021 ◽  
Vol 6 (11) ◽  
pp. 162
Author(s):  
Hao Bai ◽  
Younes Aoues ◽  
Jean-Marc Cherfils ◽  
Didier Lemosse

The vibration of wind turbine towers is relevant to the reliability of the wind turbine structure and the quality of power production. It produces both ultimate loads and fatigue loads threatening structural safety. This paper aims to reduce vibration in wind turbine towers using an active damper named the twin rotor damper (TRD). A single degree of freedom (SDOF) oscillator with the TRD is used to approximate the response of wind turbines under a unidirectional gusty wind with loss of the electrical network. The coincidence between the wind gust and the grid loss is studied to involve the maximum loading on the structure. The performance of the proposed damping system under the maximum loading is then evaluated on the state-of-the-art wind turbine NREL 5 MW. The effectiveness of the TRD is compared to a passive tuned mass damper (TMD) designed with similar requirements. The numerical results reveal that, at the 1st natural mode, the TRD outperforms the passive TMD by three to six times. Moreover, the results show that the TRD is effective in reducing ultimate loads on wind turbine towers.

Author(s):  
Touati Abdelwahed ◽  
Majdoul Radouane ◽  
Aboulfatah Mohamed ◽  
Rabbah Nabila

<p>The increasing integration of decentralized production from renewable energies on the electricity grids should contribute to improving the stability and quality of the energy produced. The main objective of this work is to prove how renewable energy sources can improve the quality of electrical energy in the grid. In particular, controlled by the oriented flux technique, a double - feed induction generator DFIG driven by a wind turbine is together used to produce active power to the electrical network and to compensate the currentharmonics generated by a non - linear load, which leads to improve the supplied energy quality. The Active filtering function consists first of all in identifying the current harmonics using the theory of instantaneous active and reactive powers quality (PQ). Then, the closed loop based on the fast terminal sliding mode control (FTSMC) control allows both the generator to follow the optimal operating point of the wind turbine and to compensate for the current harmonics. The analysis and simulation results using MATLAB/Simulink confirm the effectiveness and the limits of the proposed methods and also show the performances of the law control which provides flexibility, high precision and fast response.</p>


2016 ◽  
Vol 158 ◽  
pp. 122-138 ◽  
Author(s):  
M. Feyzollahzadeh ◽  
M.J. Mahmoodi ◽  
S.M. Yadavar-Nikravesh ◽  
J. Jamali

2020 ◽  
Vol 23 (2) ◽  
pp. 52-58
Author(s):  
S. SKRYPNYK ◽  

Our world with its high technologies has long been deeply dependent on the quality of electricity supply. In most countries of the world there are national power grids that combine the entire set of generating capacity and loads. This network provides the operation of household appliances, lighting, heating, refrigeration, air conditioning and transport, as well as the functioning of the state apparatus, industry, finance, trade, health services and utilities across the country. Without this utility, namely electricity, the modern world simply could not live at its current pace. Sophisticated technological improvements are firmly rooted in our lives and workplaces, and with the advent of e-commerce began the process of continuous transformation of the way individuals interact with the rest of the world. But with the achievement of intelligent technologies, an uninterrupted power supply is required, the parameters of which exactly meet the established standards. These standards maintain our energy security and create a reliable power system, that is maintaining the system in a trouble-free state. Overvoltage is the deviation of the rated voltage from the value of the corresponding quality standard (frequency, sinusoidal voltage and compliance of harmonics). Overvoltage in terms of fire hazard is one of the most dangerous emergency modes of electrical equipment, which causes conditions that in most cases are sufficient for the occurrence of fire hazards (exceeding the allowable voltage leads to disruption of normal operation or possible ignition). Against the background of deteriorating engineering systems, increased power consumption and poor maintenance, power supply of electrical installations, the main causes of overvoltage in electrical networks are thunderstorms (atmospheric overvoltage), switching switches, uneven phase load in electrical networks, etc. The physical picture of internal overvoltage is due to oscillatory transients from the initial to the established voltage distributions in the conductive sections due to the different situation in the electrical circuit. In the conditions of operation of electric networks planned, mode or emergency situations are possible. Therefore, the ranges of overvoltage are determined by the range from several hundred volts to tens and hundreds of kilovolts, and depend on the types of overvoltage. Atmospheric overvoltage is considered to be one of the most dangerous types of emergency modes of operation of the electrical network. This overvoltage occurs as a result of lightning discharge during precipitation by concentrating electricity on the surface of the object, the introduction of potential through engineering networks and


2017 ◽  
Vol 46 (2) ◽  
pp. 224-241 ◽  
Author(s):  
Jacob R. Fooks ◽  
Kent D. Messer ◽  
Joshua M. Duke ◽  
Janet B. Johnson ◽  
Tongzhe Li ◽  
...  

This study uses an experiment where ferry passengers are sold hotel room “views” to evaluate the impact of wind turbines views on tourists’ vacation experience. Participants purchase a chance for a weekend hotel stay. Information about the hotel rooms was limited to the quality of the hotel and its distance from a large wind turbine, as well as whether or not a particular room would have a view of the turbine. While there was generally a negative effect of turbine views, this did not hold across all participants, and did not seem to be effected by distance or hotel quality.


2011 ◽  
Vol 38 (3) ◽  
pp. 293-304 ◽  
Author(s):  
Elena Nuta ◽  
Constantin Christopoulos ◽  
Jeffrey A. Packer

The seismic response of tubular steel wind turbine towers is of significant concern as they are increasingly being installed in seismic areas and design codes do not clearly address this aspect of design. The seismic hazard is hence assessed for the Canadian seismic environment using implicit finite element analysis and incremental dynamic analysis of a 1.65 MW wind turbine tower. Its behaviour under seismic excitation is evaluated, damage states are defined, and a framework is developed for determining the probability of damage of the tower at varying seismic hazard levels. Results of the implementation of this framework in two Canadian locations are presented herein, where the risk was found to be low for the seismic hazard level prescribed for buildings. However, the design of wind turbine towers is subject to change, and the design spectrum is highly uncertain. Thus, a methodology is outlined to thoroughly investigate the probability of reaching predetermined damage states under any seismic loading conditions for future considerations.


2014 ◽  
Author(s):  
Chih-Hung Chiang ◽  
Chih-Peng Yu ◽  
Keng-Tsang Hsu ◽  
Chia-Chi Cheng ◽  
Ying-Tzu Ke ◽  
...  

2020 ◽  
Vol 11 (7-2020) ◽  
pp. 66-72
Author(s):  
Liubov A. Belova ◽  

The earth-termination system for towers of ground-based wind turbines in addition to protective and functional grounding provides lightning protection grounding, which is especially important since the wind turbine is susceptible to lightning strikes. If insufficient protective measures are taken, the risk of damage to a wind turbine due to a lightning strike increases. Therefore, a well-thought-out built-in grounding system for wind turbine towers is needed, which would function as necessary and guarantee long-term mechanical strength and corrosion resistance. The configuration of grounding systems for wind turbines is discussed in IEC 61400-24, which deals with the topic of lightning protection for wind turbines, including detailed information on the choice of lightning protection measures and surge protection. It is advisable to create a lightning protection concept at the initial stage of planning a wind turbine in order to avoid later costly repairs and retrofitting.


Sign in / Sign up

Export Citation Format