scholarly journals Mechanical Assessment of Fatigue Characteristics between Single- and Multi-Directional Cyclic Loading Modes on a Dental Implant System

Materials ◽  
2020 ◽  
Vol 13 (7) ◽  
pp. 1545
Author(s):  
Won Hyeon Kim ◽  
Eun Sung Song ◽  
Kyung Won Ju ◽  
Dohyung Lim ◽  
Dong-Wook Han ◽  
...  

Mechanical testing based on ISO 14801 standard is generally used to evaluate the performance of the dental implant system according to material and design changes. However, the test method is difficult to reflect on the clinical environment because the ISO 14801 standard does not take into account the various loads from different directions during chewing motion. In addition, the fracture pattern of the implant system can occur both in the horizontal and the vertical directions. Therefore, the purpose of this study was to compare fatigue characteristics and fracture patterns between single directional loading conditions based on the ISO 14801 standard and multi-directional loading condition. Firstly, the static test was performed on five specimens to derive the fatigue load, and the fatigue load was chosen as 40% of the maximum load measured in the static test. Subsequently, the fatigue test was performed considering the single axial/occlusal (AO), AO with facial/lingual (AOFL) and AO with mesial/distal (AOMD) directions, and five specimens were used for each fatigue loading modes. In order to analyze the fatigue characteristics, the fatigue cycle at the time of specimen fracture and displacement change of the specimen every 500 cycles were measured. Field emission scanning electron microscopy (FE-SEM) was used to analyze the fracture patterns and the fracture surface. Compared to the AO group, the fatigue cycle of the AOFL and AOMD groups showed lower about five times, while the displacement gradually increased with every 500 cycles. From FE-SEM results, there were no different surface morphology characteristics among three groups. However, the AOMD group showed a vertical slip band. Therefore, our results suggest that the multi-directional loading mode under the worst-case environment can reproduce the vertical fracture pattern in the clinical situation and may be essential to reflect on the dental implant design including connection types and surface treatments.

1998 ◽  
Vol 17 (1) ◽  
pp. 106-118 ◽  
Author(s):  
Daniel Buser ◽  
Urs C. Belser ◽  
Niklaus P. Lang

2011 ◽  
Vol 36 (4) ◽  
pp. 325-328 ◽  
Author(s):  
V. Gokce ◽  
H. Oflaz ◽  
A. Dulgeroglu ◽  
A. Bora ◽  
I. Gunal

We have studied the biomechanical stability in vitro of three different Kirschner (K) wire configurations in three types of simulated scaphoid waist fractures. The fractures were created with a saw in Sawbones models. There were three fracture patterns: perpendicular to the long axis of the scaphoid model; and 30° and 20° oblique to that. Two 1.2 mm. K-wires were used in each scaphoid. The three configurations were: parallel; 20° oblique; and crossing. The oblique or crossing configurations of K-wires were the most stable depending on the fracture pattern.


2000 ◽  
Vol 11 ◽  
pp. 22-32 ◽  
Author(s):  
Marcel Scacchi ◽  
Beat R. Merz, ◽  
Alex R. Schär

2020 ◽  
Vol 10 (17) ◽  
pp. 5826
Author(s):  
Pei-Ju Lin ◽  
Kuo-Chih Su

A dental implant is currently the most commonly used treatment for patients with lost teeth. There is no biomechanical reference available to study the effect of different occlusion conditions on dental implants with different positions. Therefore, the aim of this study was to conduct a biomechanical analysis of the impact of four common occlusion conditions on the different positions of dental implants using the finite element method. We built a finite element model that included the entire mandible and implanted seven dental implant fixtures. We also applied external force to the position of muscles on the mandible of the superficial masseter, deep masseter, medial pterygoid, anterior temporalis, middle temporalis, and posterior temporalis to simulate the four clenching tasks, namely the incisal clench (INC), intercuspal position (ICP), right unilateral molar clench (RMOL), and right group function (RGF). The main indicators measured in this study were the reaction force on the temporomandibular joint (TMJ) and the fixed top end of the abutment in the dental implant system, and the stress on the mandible and dental implant systems. The results of the study showed that under the occlusion conditions of RMOL, the dental implant system (113.99 MPa) and the entire mandible (46.036 MPa) experienced significantly higher stress, and the reaction force on the fixed-top end of the abutment in the dental implant system (261.09 N) were also stronger. Under the occlusion of ICP, there was a greater reaction force (365.8 N) on the temporomandibular joint. In addition, it was found that the reaction force on the posterior region (26.968 N to 261.09 N) was not necessarily greater than that on the anterior region (28.819 N to 70.431 N). This information can help clinicians and dental implant researchers understand the impact of different chewing forces on the dental implant system at different positions after the implantation.


2018 ◽  
Vol 12 (04) ◽  
pp. 546-552
Author(s):  
Valenzuela Rocío ◽  
Daniel Valenzuela

ABSTRACT Objective: The aim of this study is to assess the surface roughness of the implant-retained mandibular bar overdenture (BOD) and the implant-retained mandibular ball joint overdenture (BJOD) in jaw and its relation with the adhesion of molds and yeasts and mesophyll aerobe, in time 30 and 180 days in mouth. Materials and Methods: Five-systems titanium bar CARES® and synOcta® Straumann® Dental Implant System, Holding AG Inc., Basel, Switzerland (BOD), and five-systems joint ball Klockner® Implant System; Soadco Inc., Escaldes-Engordany; Andorra (BJOD), were used in two parallel groups of five participants, in an essay to simple blind person. To 30 and 180 days, the overdentures were withdrawn and evaluated the Ra: ųm. SJ-301® Mitutoyo Corporation Inc., Kanagawa, Japan, and the adhesion of microorganisms (colony-forming unit/ml). Results: The results were as follows: the Ra: Um (30th and 180th): BOD, 0.965–1.351; BJOD, 1.325–2.384. Adhesion: Molds and yeasts, BOD, 2.6 × 102 and 4.6 × 103; BJOD, 3.0 × 102 and 5.3 × 104. Adhesion: Mesophyll aerobe, BOD, 3.8 × 106 and 5.8 × 106; BJOD, 4.3 × 106 and 7.1 × 107. Conclusions: At 30 days (P = 0.489), there were no differences in BOD and BJOD for adhesion of molds and yeasts and mesophyll aerobe between both overdentures. At 180 days (P = 0.723), there were differences in the adhesion of mold and yeast and mesophyll aerobe, being greater in BJOD.


2019 ◽  
Vol 223 ◽  
pp. 775-783 ◽  
Author(s):  
Songtao Lv ◽  
Chengdong Xia ◽  
Lingyun You ◽  
Xiaofeng Wang ◽  
Jianglong Li ◽  
...  