scholarly journals The Effects of Erbium-Doped Yttrium Aluminum Garnet Laser (Er: YAG) Irradiation on Sandblasted and Acid-Etched (SLA) Titanium, an In Vitro Study

Materials ◽  
2020 ◽  
Vol 13 (18) ◽  
pp. 4174
Author(s):  
Antonio Scarano ◽  
Felice Lorusso ◽  
Francesco Inchingolo ◽  
Francesca Postiglione ◽  
Morena Petrini

The treatment of peri-implantitis implies the decontamination of the surface of the fixture. This study aims to analyze the effect of the erbium-doped yttrium aluminum garnet laser (Er: YAG) on sandblasted and acid-etched (SLA) titanium. 30 titanium SLA disks were divided into three groups. In Group 1, the disks were left intact; on the contrary, both Groups 2 and 3 were irradiated with the Er: YAG laser at different settings, with a pulse duration of 300 μs and a period of 30 s. Group 2 was irradiated at 1 W and 100 mJ/pulse and Group 3 at 4 W and 400 mJ/pulse. The superficial changes at chemical, nano, and microscopical levels were detected through the use of Fourier-transform infrared spectroscopy, atomic force microscopy, and scanning electron microscope. The Kruskal–Wallis test, followed by the Dunn–Bonferroni Post Hoc analysis, detected the presence of statistically significant differences among the groups. The level of significance was p ≤ 0.05. Results showed that Er: YAG irradiation promoted a significant (p < 0.05) increase of oxides and a decrease of microscopical roughness and porosity on SLA disks. However, the protocol tested on group 3 seemed to be too aggressive for the titanium surface, as shown by the presence of micro-cracks and signs of coagulation, melting, and microfractures. In conclusion, Group 2 showed significantly minor surface alterations with respect to Group 3, and the increase of superficial oxide level, the decrease of porosity, and micro-roughness represent a positive alteration that could protect the materials against bacterial adhesion.

2007 ◽  
Vol 18 (1) ◽  
pp. 20-23 ◽  
Author(s):  
João Vicente Baroni Barbizam ◽  
Matheus Souza ◽  
Doglas Cecchin ◽  
Jakob Dabbel

The purpose of this in vitro study was to evaluate the ability of a silicon-based root canal sealer, compared to zinc oxide and eugenol and an epoxy resin-based sealers, for filling of simulated lateral canals. Thirty extracted single-rooted human teeth were selected, conventional access was made and the working length was established 1 mm from the apical foramen. Three simulated lateral canals, one in each root third (coronal, middle and apical) were prepared in both the mesial and distal surfaces of each tooth using a size 15 reamer adapted to a low-speed handpiece. Each root canal was instrumented using ProTaper rotary files up to file F3 at the working length, and then irrigated with 2.5% NaOCl followed by EDTA. The teeth were assigned to 3 groups (n=10), according to the root canal sealer: Roeko Seal (Group 1), Sealer 26 (group 2) and Grossman's sealer (Group 3). Gutta-percha cold lateral condensation technique was performed in all groups. Postoperative radiographs were taken and the images were projected for evaluation of the quality of lateral canal filling. Data were submitted to statistical analysis by Kruskal Wallis test at 5% significance level. The results showed that Grossman's sealer filled a larger number of lateral canals than Roeko Seal (p<0.05) and Sealer 26 (p<0.01). It may be concluded that Roeko Seal silicone-based root canal sealer was not as effective as the Grossman's sealer for filling of simulated lateral canals. The lateral canals localized in the apical third of the root were more difficult to be filled.


Author(s):  
Deebah Choudhary

Aim: The aim of this study was to evaluate the canal cleaning efficacy of these three file systems using scanning electron microscopy. Place and Duration of Study: The study was conducted in the Department of Conservative dentistry and Endodontics, Institute of Dental Sciences Sehora, between October 2020 and December 2020. Materials and Methods: Access cavity preparation was performed on sixty extracted human mandibular premolar teeth and working length was determined. The samples were randomly divided into three groups (n=20) depending upon the file system used i.e. Group 1 (Reciproc Blue), Group 2 (Waveone Gold) and Group 3 (F360). Samples were split into two halves by creating longitudinal grooves on the buccal and lingual surfaces. The samples were sputter-coated with gold and examined under scanning electron microscope at 5000X. The dentinal wall of root canal at coronal, middle and apical thirds of each sample were evaluated for the presence of determining the canal cleanliness and then analyzed using a five-score index. Results: The results of this study revealed that Group 1 (Reciproc Blue) exhibited better cleaning efficacy than samples of Group 2 (WaveOne Gold) and Group 3 (F360) at different locations in the canal i.e. coronal, middle and apical. The mean debris present was highest in coronal area for both group 2 and group 3 i.e. 2.1 and least was seen in apical area of group 1 i.e. 0.3. (p<0.05) Conclusion: Reciproc Blue single-file showed highest cleaning efficacy followed by Waveone Gold and F360. Reciproc file also showed effective cleaning in the apical third of the canal.


2007 ◽  
Vol 77 (4) ◽  
pp. 701-706 ◽  
Author(s):  
Rodney G. Northrup ◽  
David W. Berzins ◽  
Thomas Gerard Bradley ◽  
William Schuckit

Abstract Objective: To evaluate and compare the shear bond strengths of two adhesives using two types of brackets: a conventional and a self-ligating bracket system. Materials and Methods: Sixty extracted human premolars were collected. The premolars were randomly divided into three groups of 20 teeth. All three groups were direct bonded. Groups 1 and 2 used light-cured adhesive and primer (Transbond XT) with a conventional (Orthos) and a self-ligating bracket (Damon 2), respectively. Group 3 used a light-cured primer (Orthosolo) and a light-cured adhesive (Blūgloo) with a self-ligating bracket (Damon 2). The specimens were stored in distilled water at 37°C for 40 ± 2 hours, after which they were debonded and inspected for Adhesive Remnant Index (ARI) scoring. Results: The mean shear bond strength was 15.2 MPa for group 1, 23.2 MPa for group 2, and 24.8 MPa for group 3. A one-way analysis of variance and post hoc Tukey test showed significant differences in bond strength (P &lt; .001) between group 1 and groups 2 and 3 but no significant difference (P &gt; .05) between groups 2 and 3. A Weibull analysis demonstrated that all three groups provided sufficient bond strength with over 90% survival rate at normal masticatory and orthodontic force levels. A Kruskal-Wallis test showed no significant difference (P &gt; .05) in ARI scores among all three groups. Conclusions: All three groups demonstrated clinically acceptable bond strength. The Damon 2 self-ligating bracket exhibited satisfactory in vitro bond strength with both adhesive systems used.


Author(s):  
A. Anushree ◽  
Ashutosh Shetty ◽  
Crystal Runa Soans ◽  
M. N. Kuttappa ◽  
Akhil Shetty ◽  
...  

Abstract Aim: The study aimed to evaluate the shear bond strength (SBS) of metal brackets and adhesive properties of bonded irradiated and non-irradiated teeth. Methods: Sixty-six extracted premolar samples were randomly divided into three groups—(a) Control group consisting of 22 non-irradiated, non-aged teeth (Group 1), (b) 22 non-irradiated, aged samples (Group 2) and (c) 22 irradiated, aged samples (Group 3). Irradiation was done using gamma irradiation with a fractionated dose of 60 Gy for 5 consecutive days per week over 6 weeks. Metal brackets were bonded on all samples with light cure adhesive and subjected to SBS test using universal testing machine. The samples were assessed under the scanning electron microscope to check for the adhesive remnant index (ARI) and tag depth. Results: There was a statistically significant decrease in the mean SBS of the irradiated samples compared to the non-irradiated teeth. The non-irradiated, aged samples showed a majority of ARI scoring 1 and 2. Whereas, the irradiated samples showed ARI scoring 2 and 3. Approximately, 77·3% of the non-irradiated samples showed no adhesive present on the tooth surface, and 27·2% of the irradiated samples had more than 50% adhesive present on the enamel surface. Conclusion: There is a statistically significant decrease in SBS of irradiated enamel compared to that of non-irradiated teeth. However, the SBS observed in the three groups was well above the ideal SBS for orthodontic bonding, that is, 5·6–6·8 MPa. The adhesive remnant was found on all samples of the irradiated group. Deeper adhesive resin tags were found in the irradiated group in the resin–enamel interface.


Sign in / Sign up

Export Citation Format

Share Document