scholarly journals Comparative Evaluation of Cleaning Efficacy of Three Different Single File Systems: An In Vitro Study

Author(s):  
Deebah Choudhary

Aim: The aim of this study was to evaluate the canal cleaning efficacy of these three file systems using scanning electron microscopy. Place and Duration of Study: The study was conducted in the Department of Conservative dentistry and Endodontics, Institute of Dental Sciences Sehora, between October 2020 and December 2020. Materials and Methods: Access cavity preparation was performed on sixty extracted human mandibular premolar teeth and working length was determined. The samples were randomly divided into three groups (n=20) depending upon the file system used i.e. Group 1 (Reciproc Blue), Group 2 (Waveone Gold) and Group 3 (F360). Samples were split into two halves by creating longitudinal grooves on the buccal and lingual surfaces. The samples were sputter-coated with gold and examined under scanning electron microscope at 5000X. The dentinal wall of root canal at coronal, middle and apical thirds of each sample were evaluated for the presence of determining the canal cleanliness and then analyzed using a five-score index. Results: The results of this study revealed that Group 1 (Reciproc Blue) exhibited better cleaning efficacy than samples of Group 2 (WaveOne Gold) and Group 3 (F360) at different locations in the canal i.e. coronal, middle and apical. The mean debris present was highest in coronal area for both group 2 and group 3 i.e. 2.1 and least was seen in apical area of group 1 i.e. 0.3. (p<0.05) Conclusion: Reciproc Blue single-file showed highest cleaning efficacy followed by Waveone Gold and F360. Reciproc file also showed effective cleaning in the apical third of the canal.

2007 ◽  
Vol 18 (1) ◽  
pp. 20-23 ◽  
Author(s):  
João Vicente Baroni Barbizam ◽  
Matheus Souza ◽  
Doglas Cecchin ◽  
Jakob Dabbel

The purpose of this in vitro study was to evaluate the ability of a silicon-based root canal sealer, compared to zinc oxide and eugenol and an epoxy resin-based sealers, for filling of simulated lateral canals. Thirty extracted single-rooted human teeth were selected, conventional access was made and the working length was established 1 mm from the apical foramen. Three simulated lateral canals, one in each root third (coronal, middle and apical) were prepared in both the mesial and distal surfaces of each tooth using a size 15 reamer adapted to a low-speed handpiece. Each root canal was instrumented using ProTaper rotary files up to file F3 at the working length, and then irrigated with 2.5% NaOCl followed by EDTA. The teeth were assigned to 3 groups (n=10), according to the root canal sealer: Roeko Seal (Group 1), Sealer 26 (group 2) and Grossman's sealer (Group 3). Gutta-percha cold lateral condensation technique was performed in all groups. Postoperative radiographs were taken and the images were projected for evaluation of the quality of lateral canal filling. Data were submitted to statistical analysis by Kruskal Wallis test at 5% significance level. The results showed that Grossman's sealer filled a larger number of lateral canals than Roeko Seal (p<0.05) and Sealer 26 (p<0.01). It may be concluded that Roeko Seal silicone-based root canal sealer was not as effective as the Grossman's sealer for filling of simulated lateral canals. The lateral canals localized in the apical third of the root were more difficult to be filled.


2015 ◽  
Vol 5 (2) ◽  
pp. 65-68
Author(s):  
Shruti Patil ◽  
Prajna Shetty

ABSTRACT Background The dentin desensitizers available for in-office application for prevention and/or treatment of post restorative dentinal hypersensitivity, act by blocking the open dentinal tubules. In doing so, they may influence the bond strength of the restorative resins. Thus, the aim of the study was to evaluate the effect of desensitizers on the shear bond strength of dentin adhesives and to check the extent of dentinal tubule occlusion caused by these desensitizers. Materials and Methods Sixty-four premolars were randomly divided into four groups of sixteen each. The middle depth dentin was exposed by on the buccal surface and was etched using 37% phosphoric acid and rinsed. They were assigned to, Group 1: Gluma desensitizer, Group 2: Vivasens desensitizer, Group 3: Gluma Comfort Bond and desensitizer, and Group 4: Adper Single Bond 2. Composite resin post of 2 mm in height and width were built on these specimens. The samples were then mounted in acrylic resin blocks. Universal testing machine was used to test the shear bond strength. The data were analyzed using one-way analysis of variance (ANOVA) and post hoc Tukey's test. Results The mean values of the shear bond strength were for: Group 1—18.61 ± 1.03 MPa, Group 2—17.53 ± 1.36 MPa, Group 3—22.63 ± 1.61 MPa and Group 4—23.12 ± 1.02 MPa. There was a statistically significant difference (p < 0.05) among the groups. Conclusion The use of dentin desensitizers’ influences bond strength between the tooth and the adhesive. Among the various agents, the single bottle system containing Gluma comfort bond and desensitizer had the best adhesion among the desensitizer groups. How to cite this article Patil S, Naik B, Shetty P. A Comparative Evaluation of Three Commercially Available Dentin Desensitizers on the Shear Bond Strength of Composite Resins: An in vitro Study. J Contemp Dent 2015;5(2):65-68.


2019 ◽  
Vol 64 (5) ◽  
pp. 555-562 ◽  
Author(s):  
Marie Kotthaus ◽  
Istabrak Hasan ◽  
Ludger Keilig ◽  
Manfred Grüner ◽  
Christoph Bourauel ◽  
...  

Abstract The aim of this study was to investigate the retention forces of secondary telescopic crowns made of polyetherketoneketone (PEKK) in combination with primary crowns made of four different dental alloys and to determine whether the retention forces change in the course of up to 5000 simulated wear cycles. A total of four groups of telescopic crowns were investigated: group 1: 10 primary crowns made of a gold alloy (NEOCAST®3), group 2: 10 primary crowns made of a non-precious metal alloy (Girobond NB), group 3: 10 primary crowns made of zirconium (Cercon®base) and group 4: 10 primary crowns made from PEKK (Pekkton®ivory). The corresponding secondary crowns were made from PEKK in all the four groups. Each pair was fixed axially in a wear simulator specifically designed for the study. Overall, 10,000 joining and separating cycles were performed for each group. To simulate intraoral conditions, a saliva substitute served as a lubricant. Force transducers were used to record the retention forces and after completing 10,000 cycles, the surface of each primary crown was examined using a scanning electron microscope (SEM). All groups showed an increase in the retention force for the first 2000 cycles which stayed constant for the remaining 8000 cycles. The Pekkton®ivory/Pekkton®ivory and NEOCAST®3/Pekkton®ivory combinations displayed mean retention force values of 16 N after a slight increase in the retention force. The Cercon®base/Pekkton®ivory and Girobond NB/Pekkton®ivory combinations displayed an initially high increase in the retention force and then showed a mean retention force of up to 29 N. All primary crowns displayed surface wear. Zirconium primary crowns showed the least wear compared to PEKK and the gold and non-precious metal alloys.


Author(s):  
Derivaldo Moura Gois Filho ◽  
Vanessa Tavares de Gois-Santos ◽  
Ronaldo Santos Silva ◽  
Antônio Carlos Marqueti ◽  
Arthur Rodriguez Gonzalez Cortes ◽  
...  

Introduction: The adaptation of prostheses fixed over implants involves biomechanical aspects that are directly associated with treatment success. Objective: The aim of this in vitro study was to evaluate the presence of microgaps in the abutment/inner connection interface of cone morse dental implants. Materials and methods: Two groups of implants were analyzed. The first group (n = 16) employed single-manufacturer dental implants and abutments, whereas the second group (n = 16) combined multi-manufacturer materials. The sets were analyzed through scanning electron mi­croscopy, wherein microgaps between the implant connection and the abutment were observed. Results: Group 1 had an average microgap of 5.69 μm (SD ± 8.46 μm). Group 2 had an average microgap of 1.24 μm (SD ± 0.44 μm). A significant difference was found between the two groups (p = 0.002). Conclusion: Within the limitations of this study, results suggest that the group formed by multi-manufacturer implants and abutments (group 2) had smaller microgap values, and, therefore, a higher in vitro adaptation of components. DESCRIPTORS | Dental Implants; Dental Abutments; Scanning Electron Microscopy.


2018 ◽  
Vol 14 (2) ◽  
Author(s):  
K Licla

Objetive: To compare the microleakage of a resinsealant using fifth generation adhesive systems,seventh generation with or without preconditioningof orthophosphoric acid at 37%. Materials and Methods: An in vitro study wasmade on 60 human premolars, randomized into4 groups of 15 elements each. Group 1 (control):phosphoric acid at 37%, sealant; Group 2: orthophosphoricacid, adhesive of fifth generation, sealant; Group 3: adhesive of seventh generation,sealant; Group 4: orthophosphoric acid, adhesiveof seventh generation, sealant. They were puton a thermocycler, 500 cycles (5° y 55°C) per 30seconds on higher and lower temperatures, afterthat the specimens were drawn for 24 hours on1% methylene blue, cut off on a bucco-lingualway and evaluated on a stereomicroscope on 16x.Chi square test was used with a 0.05 significancelevel. Results: The greater percentage of microleakageshowed: control-adhesive without (53.3%), fifthgeneration (20%), the seventh generation (80%)and conditioning with orthophosphoric acid andadhesive seventh generation (67.7%). Conclusion: Microfiltration grade adhesivesealant fifth generation was lower than using theother adhesives.


2016 ◽  
Vol 20 (2) ◽  
pp. 99-103
Author(s):  
Katerina Zlatanovska ◽  
Ljuben Guguvcevski ◽  
Risto Popovski ◽  
Cena Dimova ◽  
Ana Minovska ◽  
...  

Summary Background: The aim of this in vitro study was to examine the fracture load of composite veneers using three different preparation designs. Material and methods: Fifteen extracted, intact, human maxillary central incisors were selected. Teeth were divided into three groups with different preparation design: 1) feather preparation, 2) bevel preparation, and 3) incisal overlap- palatal chamfer. Teeth were restored with composite veneers, and the specimens were loaded to failure. The localization of the fracture was recorded as incisal, gingival or combined. Results: Composite veneers with incisal overlap - palatal chamfer showed higher fracture resistance compared to feather preparation and bevel preparation. The mean (SD) fracture loads were: Group 1: 100.6±8.0 N, Group 2: 107.4±6.8 N, and Group 3: 122.0±8.8 N. The most common mode of failure was debonding for veneers with feather preparation and fracture when incisal edge is reduced. The most frequent localization of fracture was incisal. Conclusion: The type of preparation has a significant effect on fracture load for composite veneers. This study indicates that using an incisal overlap- palatal chamfer preparation design significantly increases the fracture resistance compared to feather and bevel preparation designs.


2013 ◽  
Vol 14 (4) ◽  
pp. 629-634 ◽  
Author(s):  
E Sujayeendranath Reddy ◽  
Dinapadu Sainath ◽  
M Narenderreddy ◽  
Srikanth Pasari ◽  
Sangeetha Vallikanthan ◽  
...  

ABSTRACT Aim This in vitro study is an attempt to compare the effectiveness in cleaning oval shaped root canals usingAnatomic Endodontic Technology (AET®), ProFile system® and Manual Instrumentation with K-files Methodology Sixty oval shaped single rooted maxillary and mandibular premolars with straight canals were divided in to three groups. The root canals were, confirmed as being oval shape by means of radiographs made in a buccolingual and mesiodistal direction. Automated canal preparation was performed using Anatomic Endodontic Technology (group 1) and the ProFile system® (group 2). Manual instrumentation (group 3) was performed with k-files. Irrigation was performed using alternatively 3% NaOCl and 17% EDTA, followed by rinsing with normal saline. The roots were split longitudinally into two halves and examined under a scanning electron microscope. The presence of debris and smear layer was recorded at distances 1, 5 and 10 mm from the working length using a three step scoring scale. Mean scores for debris and smear layer was calculated and statistically analyzed for between and within groups significance, using the Kruskal-Wallis nonparametric ANOVA test and Bonferroni's multiple comparison test. Results At 1, 5 and 10 mm levels the root canals prepared with AET had significantly less surface debris and smear layer on the canal walls as compared to canals prepared with ProFile system® or manual instrumentation. For all three groups significantly lower mean smear layer scores (p < 0.05) were recorded at 5 and 10 mm levels compared with the 1 mm level. Significantly lower mean debris scores (p < 0.05) were also recorded at 5 and 10 mm levels for the AET group whereas no significant differences were found between the three levels for the ProFile system® and manual instrumentation groups. Conclusion Although better instrumentation scores were obtained in canals prepared with AET, complete cleanliness was not achieved with any of the techniques and instruments investigated. How to cite this article Reddy ES, Sainath D, Narenderreddy M, Pasari S, Vallikanthan S, Sindhurareddy G. Cleaning Efficiency of Anatomic Endodontic Technology, ProFile System and Manual Instrumentation in Oval-shaped Root Canals: An in vitro Study. J Contemp Dent Pract 2013;14(4):629-634.


2013 ◽  
Vol 14 (5) ◽  
pp. 790-795 ◽  
Author(s):  
G Vinay Kumar ◽  
Basanagouda S Patil ◽  
BK Raghavendra Rao ◽  
SM Sharathchandra ◽  
Reshma Hegde

ABSTRACT Aim The aim of the present study was to investigate the effectiveness of the one total-etch self-priming adhesive, one two-step self-etching primer adhesive, and one ‘all-in-one’ selfetching adhesive system on the adhesion of a resin composite to enamel. Materials and methods Thirty-six freshly extracted human mandibular molars were selected for this study. A flat area about 5 mm in diameter was created on the exposed mesial surface of enamel of each tooth by moist grinding with 320, 420 and 600 grit silicon carbide paper. Twelve teeth were randomly assigned into three groups. In group 1, Adper Easy One (3M ESPE), a one step self-etching primer adhesive was applied and light curing unit for 10 seconds. In group 2, Adper SE Plus, a twostep self-etching primer with bottle A containing the aqueous primer and bottle B containing the acidic adhesive was applied and light cured for 10 seconds. Group 3 (control)—etchant 37% phosphoric acid is applied to the surface for 15 seconds and rinsed with water and air dried and adhesive (single bond 2) is applied to the surface and tube is placed and light cured for 20 seconds. Composite material (Z350) was placed in the tube and light cured for 40 seconds in all the groups. Bond strength testing was done using universal testing machine at the enamel-composite interface. The debonded enamel surface was evaluated in stereomicroscope to assess the cohesive, adhesive or mixed fracture. Data was statistically analyzed by one way analysis of variance (ANOVA). Results Group 1 performed least among all groups with a mean score of 19.46 MPa. Group 2 had a mean score of 25.67 MPa. Group 3 had a mean score of 27.16 MPa. Conclusion Under the conditions of this in vitro study, the bond strength values of the two-step self-etching primer systems tested were similar to the total-etch. And, one step self-etching primers have lower bond strength compared to the total-etch. How to cite this article Patil BS, Rao BKR, Sharathchandra SM, Hegde R, Kumar GV. Comparative Evaluation of Selfetching Primers and Phosphoric Acid Effectiveness on Composite to Enamel Bond: An in vitro Study. J Contemp Dent Pract 2013;14(5):790-795.


2021 ◽  
Vol 10 (28) ◽  
pp. 2089-2093
Author(s):  
Sanath Kumar Shetty ◽  
Feba Maria Varghese ◽  
Mohammed Zahid ◽  
Savitha Dandekeri ◽  
Fowzaan Feroz

BACKGROUND This in-vitro study was conducted to compare the effect of different sintering cycles on the surface hardness of full contour monolithic Zirconia. METHODS In this in-vitro study, a total of 28 bar shaped Zirconia samples of final dimensions 20 x 4 x 2 mm were fabricated using Amann Girrbach CAD - CAM unit. These samples were randomly allocated into four groups with 7 samples in each group namely, Group 1, 2, 3 and 4 (Group 1: Long sintering cycle, Group 2: Intermediate sintering cycle, Group 3: Short sintering cycle, Group 4: Ultra-short sintering cycle) and sintered under the respective sintering cycles. The Ceramill® Therm sintering furnace provided 3 sintering cycles ranging from the longest Group - 1 (19 hours), to the short sintering cycle Group - 3 (8 hours), with an intermediate sintering cycle Group - 2 (15hours). The Zircom sintering furnace provided an ultra-short sintering cycle Group - 4 (2 hours). The testing of surface hardness was performed using TECSOL hardness tester. Statistical analysis of the collected data was performed by one - way ANOVA using SPSS software. Multiple comparison was done using post-hoc Tukey’s test. RESULTS One - way ANOVA showed statistically significant difference in the surface hardness of different samples (P < 0.05). The highest mean hardness was observed in Group 3 with 2713.757 + 233.89 VHN, followed by Group 2 with 2595.714 + 62.35 VHN, followed by Group 4 with 2518.600 + 103.65 VHN and Group 1 with the least, 1734.300 + 460.20 VHN. CONCLUSIONS The surface hardness of full contour monolithic Zirconia was influenced to some extent by various sintering cycles. The longest sintering cycle showed the least surface hardness whereas, the short sintering cycle showed the highest surface hardness. Also the ultra-short sintering cycle of 2 hours exhibited surface hardness comparable to the other sintering cycles with longer duration, making it a viable alternative to the conventional sintering cycles. KEY WORDS Monolithic Zirconia, CAD - CAM, Sintering, Hardness


2011 ◽  
Vol 2 (1) ◽  
pp. 35-38
Author(s):  
BS Keshava Prasad ◽  
Sunu Sudhakaran

ABSTRACT The aim of this study was to compare and evaluate the coronal microleakage following endodontic treatment of teeth restored with three different intracoronal restorations using calcium-45 radioisotope and autoradiography. A total of 48 extracted human mandibular premolars with single canals were divided into three experimental groups of 16 specimens each. The teeth were sectioned horizontally at the cementoenamel junction and at the middle-third of the root, orifices and canals were enlarged with Gates Glidden bur and finished using K files, and obturated with gutta-percha cones using lateral condensation technique. 3 mm of gutta-percha were removed from the coronal part of the teeth to prepare a clean 3 mm deep cavity for the coronal restorative material. Group 1 consisted of teeth restored with Ketac Molar Easymix; group 2 with Miracle Mix and group 3 with Filtek Z350. The teeth were then thermocycled and tested for microleakage using calcium-45 radioisotope. The results were analyzed using Kruskal-Wallis test and Mann-Whitney test. Filtek Z350 exhibited the least leakage followed by Ketac Molar Easymix and Miracle Mix, and the microleakage among the three restorative materials was statistically significant.


Sign in / Sign up

Export Citation Format

Share Document