scholarly journals The Fouling Behavior of Steam Generator Tube at Different Positions in the High-Temperature Water

Metals ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 684
Author(s):  
Tong Zhang ◽  
Guihui Qiu ◽  
Hongying Yu ◽  
Peng Zhou ◽  
Shicheng Wang ◽  
...  

The fouling behavior of a steam generator (SG) tube was investigated at different positions after 500 h of immersion in high-temperature water. A triple-layer structure of fouling appeared at both the crevice position and the free span position, namely, the large, dispersedly distributed deposition layer on the top; the small and faceted outer layer; and the relatively continuous inner layer. There was no obvious positional effect on the thickness of the inner layer. However, in the crevice position, the density of the deposited particle and the thickness of the outer layer was much higher than those of the free span position. The tube support plate (TSP) made of 410 stainless steel contributed significantly to the fouling behavior of the SG tube in the crevice between the SG tube and the TSP.

CORROSION ◽  
10.5006/1803 ◽  
2016 ◽  
Vol 72 (5) ◽  
pp. 655-664 ◽  
Author(s):  
Jibo Tan ◽  
Xiaoqiang Liu ◽  
Xuelian Xu ◽  
En-Hou Han ◽  
Xinqiang Wu ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document