scholarly journals Performance of a Nozzle to Control Bath Level Oscillations and Turbulence of the Metal-Flux Interface in Slab Molds

Metals ◽  
2022 ◽  
Vol 12 (1) ◽  
pp. 140
Author(s):  
María Guadalupe González-Solórzano ◽  
Rodolfo Davila Morales ◽  
Javier Guarneros ◽  
Carlos Rodrigo Muñiz-Valdés ◽  
Alfonso Nájera Bastida

The characterization of the turbulent flow of liquid steel in a slab mold using a commercial nozzle was carried out through physical experiments and mathematical models. Six ultrasonic sensors were located at each side of the nozzle to obtain real-time plotting of the bath levels during the experimental time. An ultrasonic transducer located in the mold, 20 mm below the meniscus, determines the velocities and the turbulent variables along with the distance from the narrow face to the position of the nozzle’s outer wall. These data, together with the mathematical simulations, demonstrated a high correlation of bath level oscillations and the time-dependent behavior of the discharging jets. The flow inside the mold shows low-frequency non-symmetric patterns without a severe turbulent in the meniscus. The source of this instability is the partial opening of the slide valve gate used to control the mass flow of liquid.

Water ◽  
2021 ◽  
Vol 13 (13) ◽  
pp. 1757
Author(s):  
Yesica Vicente-Martínez ◽  
Manuel Caravaca ◽  
Antonio Soto-Meca ◽  
Miguel Ángel Martín-Pereira ◽  
María del Carmen García-Onsurbe

This paper presents a novel procedure for the treatment of contaminated water with high concentrations of nitrates, which are considered as one of the main causes of the eutrophication phenomena. For this purpose, magnetic nanoparticles functionalized with silver (Fe3O4@AgNPs) were synthesized and used as an adsorbent of nitrates. Experimental conditions, including the pH, adsorbent and adsorbate dose, temperature and contact time, were analyzed to obtain the highest adsorption efficiency for different concentration of nitrates in water. A maximum removal efficiency of 100% was reached for 2, 5, 10 and 50 mg/L of nitrate at pH = 5, room temperature, and 50, 100, 250 and 500 µL of Fe3O4@AgNPs, respectively. The characterization of the adsorbent, before and after adsorption, was performed by energy dispersive X-ray spectroscopy, scanning electron microscopy, Brunauer-Emmett-Teller analysis and Fourier-transform infrared spectroscopy. Nitrates can be desorbed, and the adsorbent can be reused using 500 µL of NaOH solution 0.01 M, remaining unchanged for the first three cycles, and exhibiting 90% adsorption efficiency after three regenerations. A deep study on equilibrium isotherms reveals a pH-dependent behavior, characterized by Langmuir and Freundlich models at pH = 5 and pH = 1, respectively. Thermodynamic studies were consistent with physicochemical adsorption for all experiments but showed a change from endothermic to exothermic behavior as the temperature increases. Interference studies of other ions commonly present in water were carried out, enabling this procedure as very selective for nitrate ions. In addition, the method was applied to real samples of seawater, showing its ability to eliminate the total nitrate content in eutrophized waters.


2004 ◽  
Author(s):  
Jean-Guy Tartarin ◽  
Geoffroy Soubercaze-Pun ◽  
Abdelali Rennane ◽  
Laurent Bary ◽  
Robert Plana ◽  
...  

2018 ◽  
Vol 141 (4) ◽  
Author(s):  
Giovanni Pace ◽  
Dario Valentini ◽  
Angelo Pasini ◽  
Ruzbeh Hadavandi ◽  
Luca d'Agostino

The paper describes the results of recent experiments carried out in the Cavitating Pump Rotordynamic Test Facility for the dynamic characterization of cavitation-induced flow instabilities as simultaneously observed in the stationary and rotating frames of a high-head, three-bladed axial inducer with tapered hub and variable pitch. The flow instabilities occurring in the eye and inside the blading of the inducer have been detected, identified, and monitored by means of the spectral analysis of the pressure measurements simultaneously performed in the stationary and rotating frames by multiple transducers mounted on the casing near the inducer eye and on the inducer hub along the blade channels. An interaction between the unstable flows in the pump inlet and in the blade channels during cavitating regime has been detected. The interaction is between a low frequency axial phenomenon, which cyclically fills and empties each blade channel with cavitation, and a rotating phenomenon detected in the inducer eye.


FLORESTA ◽  
2015 ◽  
Vol 45 (4) ◽  
pp. 723 ◽  
Author(s):  
Thaís Pereira Freitas ◽  
Lairo David Feuchard ◽  
José Tarcísio Silva Oliveira ◽  
Juarez Benigno Paes ◽  
Marina Donária Chaves Arantes

Este trabalho teve como objetivo a caracterização anatômica e físico-mecânica da madeira de Liquidambar sp. Para tanto, foram utilizadas três árvores com oito anos de idade, provenientes de um arboreto localizado do município de Guaçuí, Espírito Santo. As características anatômicas analisadas foram as dimensões das fibras (comprimento, diâmetro total e do lume e espessura da parede), dos elementos de vasos (diâmetro tangencial e frequência) e dos raios (altura, largura e frequência). Para a caracterização físico-mecânica foram avaliadas a massa específica (básica, aparente a 12% de umidade e anidra), as contrações totais lineares e volumétrica, a resistência à flexão estática, à compressão paralela às fibras, ao cisalhamento e dureza Janka. Constatou-se frequência vascular numerosa com vasos de pequeno diâmetro tangencial, raios heterocelulares ocorrendo em baixa frequência, e fibras libriformes longas de paredes delgadas a espessas. A massa específica básica da madeira proveniente de discos retirados a 1,30 m do nível do solo foi de 0,48 g cm-3, sendo considerada média, a estabilidade dimensional foi considerada baixa, e houve grande influência da umidade nos valores de resistência da madeira. AbstractAnatomical and physical-mechanical characterization of Liquidambar sp. wood. This research aimed to improve anatomical, physical and mechanical characterization of Liquidambar sp.wood. Three trees were obtained, at eight years of age, from an arboretum located in Guaçuí, Espírito Santo State, Brazil. The analyzed variables were dimensions of the fibers (length, total diameter and diameter of the lumen and wall thickness), the vessel elements (tangential diameter and frequency), and ray (height, width and frequency). The specific gravity (basic, at 12% moisture content and dry), and total volumetric and linear shrinkages, resistance to bending, compression parallel to the fibers, shear and Janka hardness. For anatomical description it was found numerous vessels often with small tangential diameter, heterocellular rays occurring at low frequency, and long libriform fibers with thick to thin walls. The specific gravity of wood from disks taken at 1.30 m from ground level was 0.48 g cm-3, wich we considered average, the dimensional stability was low, and there was great influence of moisture in the resistance values in wood.Keywords: Anatomy; specific gravity; dimensional stability; mechanical strength.