scholarly journals Solvothermal Preparation of a Lanthanide Metal-Organic Framework for Highly Sensitive Discrimination of Nitrofurantoin and l-Tyrosine

Molecules ◽  
2021 ◽  
Vol 26 (12) ◽  
pp. 3673
Author(s):  
Tian-Tian Wang ◽  
Jing-Yi Liu ◽  
Rui Guo ◽  
Jun-Dan An ◽  
Jian-Zhong Huo ◽  
...  

Metal-organic frameworks (MOFs) have been rapidly developed for their broad applications in many different chemistry and materials fields. In this work, a multi-dentate building block 5-(4-(tetrazol-5-yl)phenyl)-isophthalic acid (H3L) containing tetrazole and carbolxylate moieties was employed for the synthesis of a two-dimensional (2D) lanthanide MOF [La(HL)(DMF)2(NO3)] (DMF = N,N-dimethylformamide) (1) under solvothermal condition. The fluorescent sensing application of 1 was investigated. 1 exhibits high sensitivity recognition for antibiotic nitrofurantoin (Ksv: 3.0 × 103 M−1 and detection limit: 17.0 μM) and amino acid l-tyrosine (Ksv: 1.4 × 104 M−1 and detection limit: 3.6 μM). This work provides a feasible detection platform of 2D MOFs for highly sensitive discrimination of antibiotics and amino acids.


2020 ◽  
Vol 49 (37) ◽  
pp. 13003-13016 ◽  
Author(s):  
Yi Du ◽  
Huayong Yang ◽  
Ruijuan Liu ◽  
Caiyun Shao ◽  
Lirong Yang

Six Ln-MOFs have been synthesized. Eu-MOF behaves a multi-responsive luminescent chemosensor toward Fe3+, Cu2+, Cr2O72− and nitrobenzene with high sensitivity, selectivity and anti-interference ability. Sensing mechanisms are discussed in detail.



CrystEngComm ◽  
2021 ◽  
Author(s):  
Yang Qiao ◽  
Zeqi Li ◽  
Mei-Hui Yu ◽  
Ze Chang ◽  
Xian-He Bu

High sensitivity and selectivity for detection of metal ions are very important to protect human health. Fluorescent metal-organic framework (MOF) as a new sensing material has attracted more and more...



The Analyst ◽  
2019 ◽  
Vol 144 (9) ◽  
pp. 3111-3118 ◽  
Author(s):  
Marieeswaran Muppidathi ◽  
Panneerselvam Perumal ◽  
Ravikumar Ayyanu ◽  
Sivanesan Subramanian

In this work, we fabricated a metal–organic framework derived magnetic porous carbon (MPC) and with ssDNA achieved specific and efficient recognition of harmful arsenate ions. The detection limit was achieved at 630 pM.



2020 ◽  
Vol 8 (5) ◽  
pp. 1008-1016 ◽  
Author(s):  
Haihan Zou ◽  
Dongyan Tian ◽  
Chao Lv ◽  
Songmei Wu ◽  
Guanxuan Lu ◽  
...  

Co–Ni ultrathin metal organic framework nanosheets exhibited extremely high sensitivity, wide linear range, low detection limit and excellent selectivity as a glucose sensing electrode material.



2019 ◽  
Vol 55 (75) ◽  
pp. 11231-11234 ◽  
Author(s):  
Yuanjing Cui ◽  
Dan Yue ◽  
Yike Huang ◽  
Jun Zhang ◽  
Zhiyu Wang ◽  
...  

By utilizing the d-PET process between ligands 4,4′-bimbp and H2pta in a Co-based mixed-ligand MOF, ZJU-109, a fluorescent turn-on sensor for Fe3+ with a detection limit as low as 0.053 μM has been demonstrated.



2019 ◽  
Vol 48 (48) ◽  
pp. 17945-17952 ◽  
Author(s):  
Tian-Yu Liu ◽  
Xiang-Long Qu ◽  
Bing Yan

A novel luminescent probe based on a Eu3+ functionalized MOF hybrid (Eu3+@1) with high sensitivity and selectivity has been proved to possess enormous potential for the determination of fleroxacin in human serum and urine.



2013 ◽  
Vol 135 (41) ◽  
pp. 15559-15564 ◽  
Author(s):  
Xingtang Rao ◽  
Tao Song ◽  
Junkuo Gao ◽  
Yuanjing Cui ◽  
Yu Yang ◽  
...  


2021 ◽  
Vol 19 (1) ◽  
pp. 953-960
Author(s):  
Min-Min Huang ◽  
Li-Na Xu

Abstract A novel porous Cd(ii) metal–organic framework (MOF) with the chemical composition of {[H3O][Cd(bci)]} n ·2n(H2O) (1, H3bci = bis(2-carboxyethyl)isocyanurate) was prepared via hydrothermal responses of H3bci and Cd(NO3)2·4H2O. Luminescent property investigations indicated that compound 1 had high sensitivity toward Fe3+, and the detection limit of Fe3+ was as low as 2.15 × 10−4 M. The application values of Fe3+ on Hepatitis B were assessed, and its associated mechanism was identified simultaneously. First, the cytotoxic mediator (TNF-α) substance released into plasma was measured through the ELISA. In addition, real-time RT-PCR was employed to determine the Hepatitis B viral replication gene relative expression levels. Finally, the novel compound’s toxicity against human normal liver cells was tested by using the CCK-8 assay.



Author(s):  
Ting Tang ◽  
Min Liu ◽  
Zhao Chen ◽  
Xingxiang Wang ◽  
Chunguang Lai ◽  
...  


2017 ◽  
Vol 5 (36) ◽  
pp. 19378-19389 ◽  
Author(s):  
Yingpan Song ◽  
Fenghe Duan ◽  
Shuai Zhang ◽  
Jia-Yue Tian ◽  
Zhihong Zhang ◽  
...  

An Fe-MOF-derived Fe3O4@mC-based aptasensor was constructed to sensitively and selectivity detect trace oxytetracycline and a low detection limit was obtained.



Sign in / Sign up

Export Citation Format

Share Document