scholarly journals Eco-Friendly UPLC–MS/MS Method for Determination of a Fostamatinib Metabolite, Tamatinib, in Plasma: Pharmacokinetic Application in Rats

Molecules ◽  
2021 ◽  
Vol 26 (15) ◽  
pp. 4663
Author(s):  
Essam Ezzeldin ◽  
Muzaffar Iqbal ◽  
Yousif A. Asiri ◽  
Ahmed Y. A. Sayed ◽  
Rashad Alsalahi

Fostamatinib is a prodrug of the active metabolite tamatinib, which is a spleen tyrosine kinase (Syk) inhibitor used in the treatment of primary chronic adult immune thrombocytopenia and rheumatoid arthritis. A highly sensitive, rapid, reliable, and green method was developed and validated using ultra-performance liquid chromatography and tandem mass spectrometry (UPLC–MS/MS) for quantification of tamatinib in rat plasma. Ibrutinib was used as internal standard and liquid–liquid extraction was applied using tert-butyl methyl ether. The analyte was separated on an AcquityTM CSH C18 (2.1 mm × 100 mm, 1.7 µm) column using mobile phase consisting of 10 mM ammonium acetate and acetonitrile (10:90) and the flow rate was 0.25 mL/min. Electrospray ionization (ESI) was carried out in positive mode. Quantitation of tamatinib and the IS was performed using multiple reaction monitoring mode with precursor-to-product transitions of m/z 471.1 > 122.0 and m/z 441.1 > 84.0, respectively. The calibration range was 0.1–1000.0 ng/mL and the linearity of the method was ≥0.997. The developed method greenness was investigated. All principal parameters for the method, including linearity, accuracy, precision, recovery, and stability, were within acceptable ranges. Tamatinib pharmacokinetic study in rats was successfully carried out using the developed method.

INDIAN DRUGS ◽  
2020 ◽  
Vol 57 (06) ◽  
pp. 32-38
Author(s):  
H. Potluri ◽  

A specific and sensitive method of liquid chromatography–tandem mass spectrometry was demonstrated for the experimental determination of venetoclax in human plasma utilising venetoclax-D8 as an internal standard. The column Xbridge C18, 50 × 4.6mm, 5 µm was used for attaining chromatographic separation by utilising 10mM ammonium formate and methanol as isocratic mobile phase in the composition ratio of 20:80 (V/V). The flow-rate selected was 0.7ml/min. Venetoclax and venetoclax-D8 are identified in multiple reaction monitoring (MRM) positive mode with proton adducts at m/z 869.53 →553.21 and m/z 877.14 → 553.23, respectively. For the successful extraction of drug as well as internal standard, liquid-liquid extraction technique was efficiently utilised. The developed technique was established in a linear concentration range of 5.0-5000.0 pg/ml along with correlation coefficient (r2) of 0.9994. Intra and inter-day precisions were found to be 0.7 to 1.90% and 0.7 to 2.0 % for venetoclax and venetoclax-D8, respectively. Accuracy was found to be within 98.6 to 101.99% and 99.17 to 101.14 % for venetoclax and venetoclax-D8, respectively. It was observed that throughout the bench top studies, post-operative stability studies and freeze-thawing cycles, venetoclax retained stability.


Molecules ◽  
2019 ◽  
Vol 24 (7) ◽  
pp. 1403 ◽  
Author(s):  
Xiaoyong Zheng ◽  
Feng Feng ◽  
Xiunan Jiang ◽  
Jieying Qiu ◽  
Xiaojun Cai ◽  
...  

Gomisin D, a lignan compound isolated from Fructus Schisandra, is a potential antidiabetic and anti-Alzheimer’s agent. Recently, gomisin D was used as a quality marker of some traditional Chinese medicine (TCM) formulas. In this study, a rapid ultra-performance liquid chromatography/tandem mass spectrometry method (UPLC-MS/MS) was developed and validated to quantify gomisin D in rat plasma for a pharmacokinetic and bioavailability study. Acetonitrile was used to precipitate plasma proteins. Separations were performed on a BEH C18 column with a gradient mobile phase comprising of acetonitrile and water (0.1% formic acid). An electrospray ionization source was applied and operated in the positive ion mode. The multiple reaction monitoring mode (MRM) was utilized to quantify gomisin D and nomilin (internal standard, IS) using the transitions of m/z 531.2 → 383.1 and m/z 515.3 → 161.0, respectively. The calibration curve was linear over the working range from 1 to 4000 ng/mL (R2 = 0.993). The intra- and interday precision ranged from 1.9% to 12.9%. The extraction recovery of gomisin D was in the range of 79.2–86.3%. The validated UPLC-MS/MS method was then used to obtain the pharmacokinetic characteristics of gomisin D after intravenous (5 mg/kg) and intragastric (50 mg/kg) administration to rats. The bioavailability of gomisin D was 107.6%, indicating that this compound may become a promising intragastrical medication. Our results provided useful information for further preclinical studies on gomisin D.


2019 ◽  
Vol 15 (3) ◽  
pp. 231-242
Author(s):  
Ping Wang ◽  
Shenmeng Jiang ◽  
Yu Zhao ◽  
Shuo Sun ◽  
Xiaoli Wen ◽  
...  

Background: It is urgently needed to clarify the pharmacokinetic mechanism for the multibioactive constituents in Traditional Chinese Medicines for its clinical applications. A rapid, sensitive and reliable ultra-performance liquid chromatography-tandem mass spectrometry method was developed and validated for the simultaneous determination of Danshensu, Ferulic acid, Astragaloside IV, Naringin, Neohesperidin and Puerarin after oral administration of Naoshuantong Granule using Carbamazepine as internal standard (IS). Methods: The plasma samples were pretreated by liquid-liquid extraction method using ethyl acetate after acidification, and separated on a Waters ACQUITY UPLC® BEH C18 column (50×2.1 mm, i.d., 1.7 µm) by gradient elution with a mobile phase composing of water (containing 0.1% formic acid) and acetonitrile at a flow rate of 0.2 mL/min. Multiple reaction monitoring (MRM) mode with both positive and negative ion mode was operated using an electrospray ionization (ESI) to detect the six compounds. Result: All calibration curves showed good linearity (r>0.99) over a wide concentration range. The intra- and inter-day precision (RSD%) was below 8.4% and the accuracy (RE%) ranged from 91.1% to 107.5%. The extraction recoveries of the six analytes and IS in the plasma were more than 77.9% and no severe matrix effect was observed. Conclusion: The fully validated method was successfully applied to the pharmacokinetics of Naoshuantong Granule.


2010 ◽  
Vol 93 (5) ◽  
pp. 1666-1671 ◽  
Author(s):  
Xi Xia ◽  
Xiaowei Li ◽  
Shuangyang Ding ◽  
Jianzhong Shen

Abstract A sensitive and reliable method has been developed and validated for the determination of chloramphenicol in poultry and swine liver using SPE and ultra-performance liquid chromatography (UPLC)/MS/MS. The liver samples were extracted with ethyl acetate, defatted with n-hexane, and further cleaned up using SPE cartridges with polymeric sorbent. An Acquity BEH C18 column was used for gradient UPLC separation, with water and acetonitrile as the mobile phase. The multiple reaction monitoring mode was used for two precursor-product ion transitions for chloramphenicol and one for the internal standard. The method was validated at 0.1, 0.3, and 1.0 µg/kg. Mean recoveries from fortified samples ranged from 95.5 to 106.7% with an RSD of 12.2%. The method LOD was <0.02 µg/kg.


2020 ◽  
Vol 32 (2) ◽  
pp. 145-148 ◽  
Author(s):  
Siyuan Chen ◽  
Jianshe Ma ◽  
Xianqin Wang ◽  
Peiwu Geng

Hair is a stable specimen and has a longer detection window (from weeks to months) than blood and urine. Through the analysis of hair, the long-term information of the drug use of the identified person could be explored. Our work is to establish an ultra-performance liquid chromatography–tandem mass spectroscopy (UPLC–MS/MS) method for simultaneous determination of methamphetamine, amphetamine, morphine, monoacetylmorphine, ketamine, norketamine, 3,4-methylenedioxymethamphetamine (MDMA), and 3,4-methylenedioxyamphetamine (MDA) in hair. Methoxyphenamine was used as an internal standard. The chromatographic separation was performed on a UPLC ethylene bridged hybrid (BEH) C18 (2.1 mm × 50 mm, 1.7 μm) column using a mobile phase of acetonitrile–water with 10 mmol/L ammonium acetate solution which containing 0.05% ammonium hydroxide. The multiple reaction monitoring in positive electrospray ionization was used for quantitative determination. The intra-day and inter-day precisions (relative standard deviation [RSD]) were below 15%. The accuracy ranged between 85.5% and 110.4%, the average recovery rate was above 72.9%, and the matrix effect ranged between 92.7% and 109.2%. Standard curves were in the range of 0.05–5.0 ng/mg, and the correlation coefficients were greater than 0.995. The established UPLC–MS/MS method was applied to analyze the hair samples successfully.


2014 ◽  
Vol 2014 ◽  
pp. 1-8 ◽  
Author(s):  
Renjie Xu ◽  
Mengyue Wang ◽  
Ying Peng ◽  
Xiaobo Li

Isoalantolactone and alantolactone are two major active ingredients that are present in many medicinal plants. In this study, a sensitive and rapid ultraperformance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method was developed for determination of the two compounds in rat plasma, separately. In this method, an electrospray ionization source was applied and operated in positive ion mode; multiple reaction monitoring (MRM) was selected for quantification using target fragment ions 233.2→187.1 for isoalantolactone (alantolactone) and 245.1→189.1 for internal standard (IS). Retention time of the lactones and IS was within 3.0 min. Further calibration suggested a linear regression can be calculated within 2.5–500 ng/mL for isoalantolactone and 4–500 ng/mL for alantolactone. This method was used to compare the pharmacokinetic characteristics of isoalantolactone and alantolactone at a single dose of 5 mg/kg into male Sprague-Dawley rats by intravenous administration separately. The levels oft1/2, Kel, CL,Cmax, and AUC were significantly increased in the alantolactone group compared to isoalantolactone. These results suggested that isoalantolactone was distributed and eliminated more rapidly than alantolactone in rats when administered, respectively.


2010 ◽  
Vol 46 (4) ◽  
pp. 665-677 ◽  
Author(s):  
Demétrius Fernandes do Nascimento ◽  
Manoel Odorico de Moraes ◽  
Fernando Antônio Frota Bezerra ◽  
Andréa Vieira Pontes ◽  
Célia Regina Amaral Uchoa ◽  
...  

To develop and validate a rapid, specific and highly sensitive method to quantify nimodipine in human plasma using dibucaine as the internal standard (IS). The analyte and IS were extracted from plasma samples by liquid-liquid extraction using hexane-ethyl acetate (1:1 v/v). The chromatographic separation was performed on a Varian® Polaris C18 analytical column (3 μm, 50 x 2.0 mm) and pre-column SecurityguardTM C18 (4.0 x 3.0 mm) with a mobile phase of Acetonitrile-Ammonium acetate 0.02 ml/L (80:20v/v). The method had a chromatographic run time of 4.5 min and linear calibration curve over the range of 0.1- 40 ng/mL (r > 0.9938). The limit of quantification was 100 pg/mL. Acceptable precision and accuracy were obtained for concentrations over the standard curve ranges. This validated method was successfully applied in determining the pharmacokinetic profile of nimodipine tablets of 30 mg administered to 24 healthy volunteers. The proposed method of analysis provided a sensitive and specific assay for nimodipine determination in human plasma. The time for the determination of one plasma sample was 4.5 min. This method is suitable for the analysis of nimodipine in human plasma samples collected for pharmacokinetic, bioavailability or bioequivalence studies in humans.


2020 ◽  
Vol 2020 ◽  
pp. 1-6
Author(s):  
Siyuan Chen ◽  
Jianshe Ma ◽  
Xianqin Wang ◽  
Quan Zhou

In this paper, a UPLC-MS/MS method was developed for the determination of ropivacaine and its metabolite 3-hydroxy ropivacaine in cerebrospinal fluid. The cerebrospinal fluid was processed by ethyl acetate liquid-liquid extraction. The multiple reaction monitoring (MRM) mode was used for quantitative analysis by monitoring the transitions of m/z 275.3 → 126.2 for ropivacaine, m/z 291.0 → 126.0 for 3-hydroxy ropivacaine, and m/z 290.2 → 198.2 for the internal standard. Standard curves for ropivacaine and 3-hydroxy ropivacaine in cerebrospinal fluid were conducted over the concentration range of 0.2–2000 ng/mL, demonstrating excellent linearity, and the lower limit of quantification was 0.2 ng/mL. The intraday precision of ropivacaine and 3-hydroxy ropivacaine was less than 11%, while the interday precision was less than 7%. The accuracy ranged between 87% and 107%, the average extraction efficiency was higher than 79%, and the matrix effect was between 89% and 98%. The developed method was then applied to a case of suspected poisoning of ropivacaine.


2020 ◽  
Vol 32 (1) ◽  
pp. 49-52
Author(s):  
Xi Bao ◽  
Bingge Huang ◽  
Yiting Mao ◽  
Zhiguang Zhang ◽  
Yunfang Zhou ◽  
...  

Byakangelicol is one of coumarins from Baizhi and has been shown to inhibit the release of PGE2 from human lung epithelial A549 cells in a dose-dependent manner. A sensitive ultra-performance liquid chromatography–tandem mass spectrometry (UPLC–MS/MS) method was developed and full validated for the quantification of byakangelicol in rat plasma. The pharmacokinetics of byakangelicol after both intravenous (5 mg/kg) and oral (15 mg/kg) administrations were studied. Chromatographic separation was performed on an ultra-performance liquid chromatography ethylene bridged hybrid (UPLC BEH) C18 column with acetonitrile and 0.1% formic acid as the mobile phase at a flow rate of 0.4 mL/min; fargesin was used as the internal standard (IS). The following quantitative analysis of byakangelicol was utilized in the multiple reaction monitoring mode. The samples were extracted from rat plasma via protein precipitation using acetonitrile. In the concentration range of 1–2000 ng/mL, the method correlated linearity (r > 0.995) with a lower limit of quantitation (LLOQ) of 1 ng/mL. Intra-day precision was less than 11%, and inter-day precision was less than 12%. The accuracy was between 92.0% and 108.7%, the recovery was better than 89.6%, and the matrix effect was between 85.9% and 98.6%. The method was successfully applied to a pharmacokinetic study of byakangelicol after intravenous and oral administration, and the absolute bioavailability was 3.6%.


Drug Research ◽  
2020 ◽  
Vol 71 (01) ◽  
pp. 36-42
Author(s):  
Harsha K. Tripathy ◽  
Nair S.V. Manju ◽  
Sreekanth Dittakavi ◽  
Ashok Zakkula ◽  
Ramesh Mullangi

AbstractIdelalisib is a selective and second-generation PI3K-δ inhibitor, approved for the treatment of non-Hodgkin lymphoma and chronic lymphocytic leukemia. In this paper, we present a fully validated dried blood spot (DBS) method for the quantitation of idelalisib from mice blood using an LC-MS/MS, which was operated under multiple reaction monitoring mode. To the punched DBS discs, acidified methanol enriched with internal standard (IS; larotrectinib) was added and extracted using tert-butyl methyl ether as an extraction solvent with sonication. Chromatographic separation of idelalisib and the IS was achieved on an Atlantis dC18 column using a mixture of 10 mM ammonium formate:acetonitrile (25:75, v/v). The flow-rate and injection volume were 0.80 mL/min and 2.0 µL, respectively. Idelalisib and the IS were eluted at ~0.98 and 0.93 min, respectively and the total run time was 2.00 min. Idelalisib and the IS were analyzed using positive ion scan mode and parent-daughter mass to charge ion (m/z) transition of 416.1→176.1 and 429.1→342.1, respectively was used for the quantitation. The calibration range was 1.01−4 797 ng/mL. No matrix effect and carry over were observed. Haematocrit did not influence DBS idelalisib concentrations. All the validation parameters met the acceptance criteria. The applicability of the validated method was shown in a mice pharmacokinetic study.