scholarly journals Occurrence and Control of Legionella in Recycled Water Systems

Pathogens ◽  
2015 ◽  
Vol 4 (3) ◽  
pp. 470-502 ◽  
Author(s):  
Patrick Jjemba ◽  
William Johnson ◽  
Zia Bukhari ◽  
Mark LeChevallier
2004 ◽  
Vol 2 (2) ◽  
pp. 83-96 ◽  
Author(s):  
A.-M. Bomo ◽  
M. V. Storey ◽  
N. J. Ashbolt

The occurrence of Aeromonas spp. within biofilms formed on stainless steel (SS), unplasticized polyvinyl chloride (uPVC) and glass (GL) substrata was investigated in modified Robbins Devices (MRD) in potable (MRD-p) and recycled (MRD-r) water systems, a Biofilm Reactor™ (BR) and a laboratory-scale pipe loop (PL) receiving simulated recycled wastewater. No aeromonads were isolated from the MRD-p whereas 3–10% of SS and uPVC coupons (mean 3.85 CFU cm−2 and 12.8 CFU cm−2, respectively) were aeromonad-positive in the MRD-r. Aeromonads were isolated from six SS coupons (67%) (mean 63.4 CFU cm−2) and nine uPVC coupons (100%) (mean 6.50×102 CFU cm−2) in the BR™ fed with recycled water and from all coupons (100%) in the simulated recycled water system (PL). Mean numbers of aeromonads on GL and SS coupons were 5.83×102 CFU cm−2 and 8.73×102 CFU cm−2, respectively. No isolate was of known human health significance (i.e. Aeromonas caviae, A. hydrophila or A. veronii), though they were confirmed as Aeromonas spp. by PCR and fluorescence in situ hybridization (FISH). Challenging the PL biofilms with a slug dose of A. hydrophila (ATCC 14715) showed that biofilm in the PL accumulated in the order of 103–104A. hydrophila cm−2, the number of which decreased over time, though could not be explained in terms of conventional 1st order decay kinetics. A sub-population of FISH-positive A. hydrophila became established within the biofilm, thereby demonstrating their ability to incorporate and persist in biofilms formed within distribution pipe systems. A similar observation was not made for culturable aeromonads, though the exact human health significance of this remains unknown. These findings, however, further question the adequacy of culture-based techniques and their often anomalous discrepancy with direct techniques for the enumeration of bacterial pathogens in environmental samples.


2020 ◽  
Vol 17 (8) ◽  
pp. 681-681
Author(s):  
David Butler ◽  
Raziyeh Farmani ◽  
Slobodan Djordjević

2010 ◽  
Vol 61 (1) ◽  
pp. 155-162 ◽  
Author(s):  
A. C. Hambly ◽  
R. K. Henderson ◽  
A. Baker ◽  
R. M. Stuetz ◽  
S. J. Khan

A rapid, highly sensitive method for detection of cross-connections between recycled and potable water in dual reticulation systems is required. The aim of this research was to determine the potential of fluorescence spectroscopy as a monitoring tool at three Australian dual distribution (drinking and recycled water) systems. Weekly grab samples of recycled and potable water were obtained over 12 weeks at each site and analysed for fluorescence excitation-emission matrix (EEM) spectroscopy, UV254, dissolved organic carbon (DOC), electrical conductivity and pH. Fluorescence EEM spectroscopy was able to differentiate between recycled and potable water at each site by monitoring the protein-like fluorescence at peak T—an excitation-emission wavelength pair of λex/em = 300/350 nm. While electrical conductivity was also able to distinguish between recycled and potable water, the differentiation was greatest when using fluorescence. For example, the peak T fluorescence in recycled water was up to 10 times that of potable water in comparison with electrical conductivity that had a maximum 5 times differentiation. Furthermore, by comparing the protein-like fluorescence at peak T and humic-like fluorescence at peak A (λex/em = 235/426 nm), the three different recycled water systems were able to be differentiated. Overall, fluorescence shows promise as a monitoring tool for detecting cross-connections.


2008 ◽  
Vol 9 (1) ◽  
pp. 22 ◽  
Author(s):  
Thorsten Ufer ◽  
Sabine Werres ◽  
Martin Posner ◽  
Hans-Peter Wessels

Three filtration systems using slow sand filtration (SSF) and one using lava grain filtration (LGF) were tested for their ability to eliminate Phytophthora spp. from recycled water in commercial ornamental nurseries over four years. Samples were taken in May, August, and October of each year. Phytophthora spp. could not be detected in any of the filter effluents when filters were operating normally. Water stored in clean water reservoirs that were filled only with filtered water and were well protected from contamination via soil and air remained free of Phytophthora. All four filtration systems produced sufficient quantities of water for nursery production. The maximum annual quantity of water demanded by the nurseries ranged from 30,000 to 163,000 m3. The cost for 1 m3 filtered water was lowest for slow sand filtration compared with lava grain filtration. Recommendations for designing systems suitable for large ornamental nurseries with open air recycling systems are discussed. Accepted for publication 20 December 2007. Published 14 March 2008.


2020 ◽  
Vol 252 ◽  
pp. 119745 ◽  
Author(s):  
Carlo Giudicianni ◽  
Manuel Herrera ◽  
Armando di Nardo ◽  
Armando Carravetta ◽  
Helena M. Ramos ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document