scholarly journals Facile Molecular Weight Determination of Polymer Brushes Grafted from One-Dimensional Diffraction Grating by SI-ATRP Using Reflective Laser System

Polymers ◽  
2021 ◽  
Vol 13 (23) ◽  
pp. 4270
Author(s):  
Jem-Kun Chen ◽  
Feng-Ping Lin ◽  
Chi-Jung Chang ◽  
Chien-Hsing Lu ◽  
Chih-Feng Huang

Gelatin was immobilized selectively on the amide groups-modified bottom of a trench array of a photoresist template with 2 μm resolution by the ethyl(dimethylaminopropyl) carbodiimide/N-hydroxysuccinimide reaction. The gelatin-immobilized line array was brominated to generate a macroinitiator for atom transfer radical polymerization. Poly(methacrylic acid) (PMAA) brushes were grafted from the macroinitiator layer as line arrays of one-dimensional diffraction gratings (DGs) for various grafting polymerization times. A laser beam system was employed to analyze the optical feature with a characteristic diffraction effect of the PMAA DGs at a 45° incident angle along the transverse magnetic and transverse electric polarization. The growth of the PMAA brush lines increased both their heights and widths, leading to a change in the reflective diffraction intensity. The PMAA brushes under various grafting polymerization times were cleaved from the substrate by digestion of gelatin with trypsin, and their molecular weights were obtained by gel permeation chromatography. The change degree of the diffraction intensity varied linearly with the molecular weight of the PMAA brushes over a wide range, from 135 to 1475 kDa, with high correlation coefficients. Molecular weight determination of polymer brushes using the reflective diffraction intensity provides a simple method to monitor their growth in real time without polymer brush cleavage.

2013 ◽  
Vol 47 (1) ◽  
pp. 269-275 ◽  
Author(s):  
Chengjun Kang ◽  
Rowena M. Crockett ◽  
Nicholas D. Spencer

1975 ◽  
Vol 39 (8) ◽  
pp. 1527-1531
Author(s):  
Zen-ichiro Hamauzu ◽  
Yukio Kamazuka ◽  
Hirokazu Kanazawa ◽  
Daizo Yonezawa

2021 ◽  
Author(s):  
Feng-Ping Lin ◽  
Hui-Ling Hsu ◽  
Hui-Chung Lin ◽  
Hsin-Hsien Huang ◽  
Chien-Hsing Lu ◽  
...  

Abstract Background: Because of the low sensitivity of commercial products, development of a facile method to rapidly identify plague on-site remains highly attractive. Line arrays of poly(methacrylic acid) (PMAA) brushes were grafted using a photoresist template to fabricate one-dimensional diffraction gratings (DGs). The as-prepared samples first bound protein G to immobilize and orient the tails of the antibody of Yersinia pestis (abY). A laser beam was employed to analyze the 2D and 3D reflective signals of DGs at an incident angle of 45°. The abY-tailed PMAA DG possessed an optical feature with a characteristic diffraction effect along the SII, in which the projection of the laser beam on the plane of the DG chip was parallel to the strips, and ST configurations, in which they were perpendicular. A fluidic diffraction chip based on the abY-tailed PMMA DG was fabricated to examine the ability to detect Yersinia pestis along the ST configuration. Results: Upon flowing through the chip, Yersinia pestis was attached to the abY-tailed PMMA DG, which changed the diffraction intensity. The degree of the diffraction intensity exhibited a linear response to Yersinia pestis at concentrations from 102 to 107 CFU mL−1, and the limit of detection was 75 CFU mL−1, 1000 times lower than a commercial product (Alexter Bio-Detect Test). The diffractive sensor could selectively detect Yersinia pestis in spiked serum samples, with excellent standard deviation and recovery. Conclusion: Our platform provides a simple, label-free method for on-site plague diagnosis to prevent the highly rapid transmission of plague.


Sign in / Sign up

Export Citation Format

Share Document