scholarly journals Agreement between Inertia and Optical Based Motion Capture during the VU-Return-to-Play- Field-Test

Sensors ◽  
2020 ◽  
Vol 20 (3) ◽  
pp. 831
Author(s):  
Chris Richter ◽  
Katherine A. J. Daniels ◽  
Enda King ◽  
Andrew Franklyn-Miller

The validity of an inertial sensor-based motion capture system (IMC) has not been examined within the demands of a sports-specific field movement test. This study examined the validity of an IMC during a field test (VU®) by comparing it to an optical marker-based motion capture system (MMC). Expected accuracy and precision benchmarks were computed by comparing the outcomes of a linear and functional joint fitting model within the MMC. The kinematics from the IMC in sagittal plane demonstrated correlations (r2) between 0.76 and 0.98 with root mean square differences (RMSD) < 5°, only the knee bias was within the benchmark. In the frontal plane, r2 ranged between 0.13 and 0.80 with RMSD < 10°, while the knee and hip bias was within the benchmark. For the transversal plane, r2 ranged 0.11 to 0.93 with RMSD < 7°, while the ankle, knee and hip bias remained within the benchmark. The findings indicate that ankle kinematics are not interchangeable with MMC, that hip flexion and pelvis tilt higher in IMC than MMC, while other measures are comparable to MMC. Higher pelvis tilt/hip flexion in the IMC can be explained by a one sensor tilt estimation, while ankle kinematics demonstrated a considerable level of disagreement, which is likely due to four reasons: A one sensor estimation, sensor/marker attachment, movement artefacts of shoe sole and the ankle model used.

2010 ◽  
Vol 26 (3) ◽  
pp. 290-294 ◽  
Author(s):  
Richard W. Bohannon ◽  
Jason Smutnick

Motion of the femur and pelvis during hip flexion has been examined previously, but principally in the sagittal plane and during nonfunctional activities. In this study we examined femoral elevation in the sagittal plane and pelvic rotation in the sagittal and frontal planes while subjects flexed their hips to ascend single steps. Fourteen subjects ascended single steps of 4 different heights leading with each lower limb. Motion of the lead femur and pelvis during the flexion phase of step ascent was tracked using an infrared motion capture system. Depending on step height and lead limb, step ascent involved elevation of the femur (mean 47.2° to 89.6°) and rotation of the pelvis in both the sagittal plane (tilting: mean 2.6° to 9.7°) and frontal plane (listing: mean 4.2° to 11.9°). Along with maximum femoral elevation, maximum pelvic rotation increased significantly (p< .001) with step height. Femoral elevation and pelvic rotation during the flexion phase of step ascent were synergistic (r= .852–.999). Practitioners should consider pelvic rotation in addition to femoral motion when observing individuals’ ascent of steps.


Author(s):  
Gunjan Patel ◽  
Rajani Mullerpatan ◽  
Bela Agarwal ◽  
Triveni Shetty ◽  
Rajdeep Ojha ◽  
...  

Wearable inertial sensor-based motion analysis systems are promising alternatives to standard camera-based motion capture systems for the measurement of gait parameters and joint kinematics. These wearable sensors, unlike camera-based gold standard systems, find usefulness in outdoor natural environment along with confined indoor laboratory-based environment due to miniature size and wireless data transmission. This study reports validation of our developed (i-Sens) wearable motion analysis system against standard motion capture system. Gait analysis was performed at self-selected speed on non-disabled volunteers in indoor ( n = 15) and outdoor ( n = 8) environments. Two i-Sens units were placed at the level of knee and hip along with passive markers (for indoor study only) for simultaneous 3D motion capture using a motion capture system. Mean absolute percentage error (MAPE) was computed for spatiotemporal parameters from the i-Sens system versus the motion capture system as a true reference. Mean and standard deviation of kinematic data for a gait cycle were plotted for both systems against normative data. Joint kinematics data were analyzed to compute the root mean squared error (RMSE) and Pearson’s correlation coefficient. Kinematic plots indicate a high degree of accuracy of the i-Sens system with the reference system. Excellent positive correlation was observed between the two systems in terms of hip and knee joint angles (Indoor: hip 3.98° ± 1.03°, knee 6.48° ± 1.91°, Outdoor: hip 3.94° ± 0.78°, knee 5.82° ± 0.99°) with low RMSE. Reliability characteristics (defined using standard statistical thresholds of MAPE) of stride length, cadence, walking speed in both outdoor and indoor environment were well within the “Good” category. The i-Sens system has emerged as a potentially cost-effective, valid, accurate, and reliable alternative to expensive, standard motion capture systems for gait analysis. Further clinical trials using the i-Sens system are warranted on participants across different age groups.


2015 ◽  
Vol 47 (1) ◽  
pp. 41-49 ◽  
Author(s):  
Isaac Estevan ◽  
Coral Falco ◽  
Julia Freedman Silvernail ◽  
Daniel Jandacka

AbstractIn taekwondo, there is a lack of consensus about how the kick sequence occurs. The aim of this study was to analyse the peak velocity (resultant and value in each plane) of lower limb segments (thigh, shank and foot), and the time to reach this peak velocity in the kicking lower limb during the execution of the roundhouse kick technique. Ten experienced taekwondo athletes (five males and five females; mean age of 25.3 ±5.1 years; mean experience of 12.9 ±5.3 years) participated voluntarily in this study performing consecutive kicking trials to a target located at their sternum height. Measurements for the kinematic analysis were performed using two 3D force plates and an eight camera motion capture system. The results showed that the proximal segment reached a lower peak velocity (resultant and in each plane) than distal segments (except the peak velocity in the frontal plane where the thigh and shank presented similar values), with the distal segment taking the longest to reach this peak velocity (p < 0.01). Also, at the instant every segment reached the peak velocity, the velocity of the distal segment was higher than the proximal one (p < 0.01). It provides evidence about the sequential movement of the kicking lower limb segments. In conclusion, during the roundhouse kick in taekwondo inter-segment motion seems to be based on a proximo-distal pattern.


Sensors ◽  
2021 ◽  
Vol 21 (12) ◽  
pp. 4240
Author(s):  
Byong Hun Kim ◽  
Sung Hyun Hong ◽  
In Wook Oh ◽  
Yang Woo Lee ◽  
In Ho Kee ◽  
...  

Gait analysis has historically been implemented in laboratory settings only with expensive instruments; yet, recently, efforts to develop and integrate wearable sensors into clinical applications have been made. A limited number of previous studies have been conducted to validate inertial measurement units (IMUs) for measuring ankle joint kinematics, especially with small movement ranges. Therefore, the purpose of this study was to validate the ability of available IMUs to accurately measure the ankle joint angles by comparing the ankle joint angles measured using a wearable device with those obtained using a motion capture system during running. Ten healthy subjects participated in the study. The intraclass correlation coefficient (ICC) and standard error of measurement were calculated for reliability, whereas the Pearson coefficient correlation was performed for validity. The results showed that the day-to-day reliability was excellent (0.974 and 0.900 for sagittal and frontal plane, respectively), and the validity was good in both sagittal (r = 0.821, p < 0.001) and frontal (r = 0.835, p < 0.001) planes for ankle joints. In conclusion, we suggest that the developed device could be used as an alternative tool for the 3D motion capture system for assessing ankle joint kinematics.