Faculty Opinions recommendation of 5'-triphosphate-dependent activation of PKR by RNAs with short stem-loops.

Author(s):  
Michael Gale
Keyword(s):  
2021 ◽  
Vol 10 (6) ◽  
pp. 1235
Author(s):  
Michael Fuchs ◽  
Marie-Anne Hein ◽  
Martin Faschingbauer ◽  
Mirco Sgroi ◽  
Ralf Bieger ◽  
...  

Because of preservation of proximal femoral bone stock and minimized soft tissue trauma, short-stem implants are becoming increasingly important in total hip arthroplasty (THA). The postulated advantage regarding the functional outcome has not been verified. We hypothesized an increased abductor muscle strength by the use of a short-stem design. Seventy consecutive patients of a randomized clinical trial were included. Of these, 67 patients met the inclusion criteria after 12 months. Thirty-five patients received a standard straight stem and 32 patients a short-stem femoral component. All surgeries were performed by a modified direct lateral approach. Isometric muscle strength of the hip abductors was evaluated preoperatively 3 and 12 months after surgery. Harris hip score (HHS) and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) scores were evaluated. After three months, there were no differences between the two groups; the abductor force was comparable to the preoperative initial values. After 12 months, a significant increase in muscle strength for the short stem patient group compared to preoperative baseline values was measured (straight-stem THA, 0.09 Nm/kg ± 0.4, p = 0.32; short-stem THA, 0.2 Nm/kg ± 0.3, p = 0.004). Comparison of the 12-month postoperative total HHS and WOMAC revealed no significant differences between both groups. A significant increase in hip abductor muscle strength 12 months after short-stem THA compared to conventional-stem THA was observed.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Georg Hauer ◽  
Maria Smolle ◽  
Sabrina Zaussinger ◽  
Joerg Friesenbichler ◽  
Andreas Leithner ◽  
...  

AbstractReturn to work (RTW) has been specifically identified as a high priority in patients undergoing total hip arthroplasty (THA). This investigation sought to assess the effect of the stem design on patients’ RTW. Secondly, the study aimed to identify risk factors that lead to a delayed RTW. Questionnaires inquiring about RTW, employment history, educational level, type of work, physical demands and joint awareness were administered by post. Further data were collected from patients’ hospital records. 176 patients who underwent THA using a short-stem and 97 patients using a straight-stem design were compared. The median return to work time was 10 weeks [IQR 7–14 weeks], with no significant difference between the two groups (short stems vs. straight stems; 10 [IQR 7–14] vs. 11 [7.5–13.5] weeks; p = 0.693). In the multivariate linear regression analysis, self-employment vs. employee (p = 0.001), dimension of preoperative workload (p = 0.001), preoperative sick leave (p < 0.001), and hospital length of stay (LOS) (p < 0.001) independently affected the period until work was resumed. The Forgotten-Joint-Score-12 showed no significant difference between the two groups. The data show that the majority of THA patients can expect to resume work and stem design has no impact on RTW. Employees with preoperative sick leave, prolonged hospital LOS and low workload are at higher risk for a delayed RTW.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Fabrizio Rivera ◽  
Alessandro Bardelli ◽  
Andrea Giolitti

Abstract Background In the last decade, the increase in the use of the direct anterior approach to the hip has contributed to the diffusion of the use of short stems in orthopedic surgery. The aim of the study is to verify the medium-term clinical and radiographic results of a cementless anatomic short stem in the anterior approach to the hip. We also want to verify whether the use of the standard operating room table or the leg positioner can affect the incidence of pre- and postoperative complications. Materials and methods All total hip arthroplasty patients with a 1-year minimum follow-up who were operated using the MiniMAX stem between January 2010 and December 2019 were included in this study. Clinical evaluation included the Harris Hip Score (HHS), Western Ontario and McMaster Universities Hip Outcome Assessment (WOMAC) Score, and Short Form-36 (SF-36) questionnaires. Bone resorption and remodeling, radiolucency, osteolysis, and cortical hypertrophy were analyzed in the postoperative radiograph and were related to the final follow-up radiographic results. Complications due to the use of the standard operating room table or the leg positioner were evaluated. Results A total of 227 patients (238 hips) were included in the study. Average age at time of surgery was 62 years (range 38–77 years). Mean follow-up time was 67.7 months (range 12–120 months). Kaplan–Meier survivorship analysis after 10 years revealed 98.2% survival rate with revision for loosening as endpoint. The mean preoperative and postoperative HHS were 38.35 and 94.2, respectively. The mean preoperative and postoperative WOMAC Scores were 82.4 and 16.8, respectively. SF-36 physical and mental scores averaged 36.8 and 42.4, respectively, before surgery and 72.4 and 76.2, respectively, at final follow-up. The radiographic change around the stem showed bone hypertrophy in 55 cases (23%) at zone 3. In total, 183 surgeries were performed via the direct anterior approach (DAA) on a standard operating room table, and 44 surgeries were performed on the AMIS mobile leg positioner. Comparison between the two patient groups did not reveal significant differences. Conclusion In conclusion, a short, anatomic, cementless femoral stem provided stable metaphyseal fixation in younger patients. Our clinical and radiographic results support the use of this short stem in the direct anterior approach. Level of evidence IV.


Author(s):  
Anatole Vilhelm Wiik ◽  
Adeel Aqil ◽  
Bilal Al-Obaidi ◽  
Mads Brevadt ◽  
Justin Peter Cobb

Abstract Aim The length of the femoral stem in total hip arthroplasty (THA) is a practical consideration to prevent gait impairment. The aim of this study was to determine if reducing the femoral stem length in THA would lead to impaired gait biomechanics. Methods Patients uniformly with the same brand implant of differing lengths (100 mm vs 140–166 mm) were taken retrospectively from a prospective trial introducing a new short stem. Twelve patients without any other disorder to alter gait besides contralateral differing length stem THA were tested at differing gradients and speed on a validated instrumented treadmill measuring ground reaction forces. An anthropometrically similar group of healthy controls were analysed to compare. Results With the same posterior surgical approach, the offset and length of both hips were reconstructed within 5 mm of each other with an identical mean head size of 36 mm. The short stem was the last procedure for all the hips with gait analysis occurring at a mean of 31 and 79 months postoperatively for the short and long stem THA, respectively. Gait analysis between limbs of both stem lengths demonstrated no statistical difference during any walking condition. In the 90 gait assessments with three loading variables, the short stem was the favoured side 51% of the time compared 49% for the long stem. Conclusion By testing a range of practical walking activities, no lower limb loading differences can be observed by reducing the femoral stem length. A shorter stem demonstrates equivalence in preference during gait when compared to a reputable conventional stem in total hip arthroplasty.


2021 ◽  
pp. 1-10
Author(s):  
Keisuke Uemura ◽  
Hidetoshi Hamada ◽  
Wataru Ando ◽  
Masaki Takao ◽  
Nobuhiko Sugano

Sign in / Sign up

Export Citation Format

Share Document