Minimum 10 years clinical results of an anatomical short stem with a proximal hydroxyapatite coating

2021 ◽  
pp. 1-10
Author(s):  
Keisuke Uemura ◽  
Hidetoshi Hamada ◽  
Wataru Ando ◽  
Masaki Takao ◽  
Nobuhiko Sugano
2021 ◽  
Vol 2 (1) ◽  
pp. 58-65
Author(s):  
Timothy James Karssiens ◽  
James Ritchie Gill ◽  
Karadi Hari Sunil Kumar ◽  
Søren Upton Sjolin

Aims The Mathys Affinis Short is the most frequently used stemless total shoulder prosthesis in the UK. The purpose of this prospective cohort study is to report the survivorship, clinical, and radiological outcomes of the first independent series of the Affinis Short prosthesis. Methods From January 2011 to January 2019, a total of 141 Affinis Short prostheses were implanted in 127 patients by a single surgeon. Mean age at time of surgery was 68 (44 to 89). Minimum one year and maximum eight year follow-up (mean 3.7 years) was analyzed using the Oxford Shoulder Score (OSS) at latest follow-up. Kaplan-Meier survivorship analysis was performed with implant revision as the endpoint. Most recently performed radiographs were reviewed for component radiolucent lines (RLLs) and proximal humeral migration. Results Five shoulders underwent revision surgery (3.5%); three for rotator cuff failure, one for infection, and one for component malposition. Survivorship of the implant was 95.4% (95% confidence interval 90.1% to 97.9%) at five and nine years. Mean OSS improved significantly compared to preoperative values from 19.0 (1 to 35) to 43.3 (7 to 48) (p < 0.001). Radiological analysis was undertaken for 99 shoulders. This revealed humeral RLLs in one case (1%), glenoid RLLs in 15 cases (15.2%), and radiological rotator cuff failure in 22 cases (22.2%). Conclusion This prospective cohort study shows encouraging short- to mid-term survivorship and clinical and radiological results for the Mathys Affinis Short, Short Stem Total Shoulder Prosthesis. Level of Evidence: IV Cite this article: Bone Jt Open 2021;2(1):58–65.


2015 ◽  
Vol 127 (9-10) ◽  
pp. 375-378 ◽  
Author(s):  
Martin Kaipel ◽  
Phillip Grabowiecki ◽  
Katrina Sinz ◽  
Sebastian Farr ◽  
Günter Sinz

Author(s):  
Benjamin D. Kleim ◽  
Christina Garving ◽  
Ulrich H. Brunner

Abstract Introduction The goal of this study was to provide an insight into the clinical results after modular short-stem shoulder arthroplasty for various indications. Materials and methods A consecutive cohort study of 76 patients followed up for 23–55 (mean 31.4) months. 23 anatomical (TSA), 32 reverse (RSA) and 21 hemi-prostheses with a pyrocarbon head (PyC), using a modular short stem with proximal porous coating were implanted. Range of motion, pain and Constant score (CS) were recorded. Comparisons of pre- vs postoperative outcomes, between prosthesis types and indications, were made. Results All prosthesis types brought about a significant improvement (p < 0.05) in all measured outcomes. TSA had a significantly higher increase in the CS than PyC and RSA (p = 0.002 and 0.003, respectively). TSA produced superior gains in all ROM compared with RSA (p < 0.02). RSA brought about significantly smaller improvements in internal rotation than TSA and PyC (p = 0.0001 and 0.008, respectively). TSA had greater pain relief than PyC (p = 0.02). TSA with Walch A glenoids seemed to improve more than type B in the CS. PyC patients with Walch B glenoids improved more than Walch A (p = 0.03). When implanted due to Osteoarthritis (OA), PyC had a comparable final outcome to TSA (p = 0.95), although the preoperatively worse TSA patients had a greater improvement in the CS (p = 0.026). The outcome of RSA did not differ between indications, but Walch A glenoids tended to improve more. Conclusions Using a second-generation short-stem shoulder prostheses, TSA achieves the best clinical improvements overall, especially for OA with a Walch A glenoid. Despite refixation of the subscapularis tendon in all cases, RSA has inferior internal rotation than TSA and PyC, suggesting a mechanical limitation. OA, a Walch B glenoid and arthritis caused by instability seem to be ideal indications when considering PyC.


1950 ◽  
Vol 14 (2) ◽  
pp. 214-227 ◽  
Author(s):  
Vernon A. Weinstein ◽  
Franklin Hollander ◽  
Frances U. Lauber ◽  
Ralph Colp

VASA ◽  
2002 ◽  
Vol 31 (1) ◽  
pp. 36-42 ◽  
Author(s):  
. Bucek ◽  
Hudak ◽  
Schnürer ◽  
Ahmadi ◽  
Wolfram ◽  
...  

Background: We investigated the long-term clinical results of percutaneous transluminal angioplasty (PTA) in patients with peripheral arterial occlusive disease (PAOD) and the influence of different parameters on the primary success rate, the rate of complications and the long-term outcome. Patients and methods: We reviewed clinical and hemodynamic follow-up data of 166 consecutive patients treated with PTA in 1987 in our department. Results: PTA improved the clinical situation in 79.4% of patients with iliac lesions and in 88.3% of patients with femoro-popliteal lesions. The clinical stage and ankle brachial index (ABI) post-interventional could be improved significantly (each P < 0,001), the same results were observed at the end of follow-up (each P < 0,001). Major complications occurred in 11 patients (6.6%). The rate of primary clinical long-term success for suprainguinal lesions was 55% and 38% after 5 and 10 years (femoro-popliteal 44% and 33%), respectively, the corresponding data for secondary clinical long-term success were 63% and 56% (60% and 55%). Older age (P = 0,017) and lower ABI pre-interventional (P = 0,019) significantly deteriorated primary clinical long-term success for suprainguinal lesions, while no factor could be identified influencing the outcome of femoro-popliteal lesions significantly. Conclusion: Besides an acceptable success rate with a low rate of severe complications, our results demonstrate favourable long-term clinical results of PTA in patients with PAOD.


VASA ◽  
2012 ◽  
Vol 41 (3) ◽  
pp. 163-176 ◽  
Author(s):  
Weidenhagen ◽  
Bombien ◽  
Meimarakis ◽  
Geisler ◽  
A. Koeppel

Open surgical repair of lesions of the descending thoracic aorta, such as aneurysm, dissection and traumatic rupture, has been the “state-of-the-art” treatment for many decades. However, in specialized cardiovascular centers, thoracic endovascular aortic repair and hybrid aortic procedures have been implemented as novel treatment options. The current clinical results show that these procedures can be performed with low morbidity and mortality rates. However, due to a lack of randomized trials, the level of reliability of these new treatment modalities remains a matter of discussion. Clinical decision-making is generally based on the experience of the vascular center as well as on individual factors, such as life expectancy, comorbidity, aneurysm aetiology, aortic diameter and morphology. This article will review and discuss recent publications of open surgical, hybrid thoracic aortic (in case of aortic arch involvement) and endovascular repair in complex pathologies of the descending thoracic aorta.


Sign in / Sign up

Export Citation Format

Share Document