Study of the reduction of the onset temperature in a loop-tube-type thermoacoustic prime mover using Conical Phase Adjuster.- Based study on the installation position and onset temperature of Conical Phase Adjuster -
Abstract In this report, we proposed the installation of a Conical Phase Adjuster (CPA) in a thermoacoustic prime mover as a method for reducing the onset temperature and investigated the effect of the installation position of CPA on the onset temperature using stability analysis. The onset temperature of CPA also was investigated experimentally by changing the installation position of CPA. As a result, when CPA was installed at 1000 mm from the high-temperature end of the stack, the onset temperature was 195 K lower than the onset temperature without CPA, that is, the installation of CPA in a loop-tube-type thermoacoustic prime mover reduced the onset temperature by 29 %. Comparing onset temperatures of PA had installed in a system, CPA is considered to have the same effect as PA because the onset temperature tendency of CPA to reduce at the installation position agrees with that of PA.