scholarly journals Neural Network based - Arrhythmia Monitoring Device: A Pivotal Clinical Trial

Arrhythmia or irregular heart beat had wide range of clinical manifestations, from benign arrhythmia that not need any medication to life threatening condition. It can occur permanently or intermittently. Intermittent arrhythmia needs specific diagnostic tools that can record the electrocardiogram continuously. This research was sought to analysed the sensitivity, specificity, Positive Predictive Value, and Negative Predictive Value of arrhythmia monitoring device that based on neural network based artificial intelligent. The pivotal clinical trial was involved a total 103 people (health and stable arrhythmia patients). This research used a diagnostic test by comparing the electrocardiography (ECG) from prototype with standard ECG for diagnose arrhythmia. The Arrhythmia Monitoring System that we developed has three hardware components; smartphones, server for arrhythmia detection and patchable ECG recorder. All three components are connected with internet of things (IoT) technology. The architecture of Arrhythmia software monitoring included ECG signals pre-processing, beats detection, features extraction for detecting VT/VF, and classification for detecting VT/VF. Features extraction such as heart rate variability (HRV) and T wave alternans. We compared the ECG of arrhythmia prototype monitoring device with standard Holter monitoring. We enrolled 103 patients. There was no significant difference of heart rate between arrhythmia prototype monitoring device and standard Holter (87.26 ± 11.2 vs 86.07±9.15, P=0.43). There was significant different of maximum and minimum heart rate between arrhythmia prototype monitoring device and standard holter monitoring (121.3±31.7 vs 131.0±10.8, p= 0.000, and 65.1±13.5 vs 73.07±10.02, p=0.000). This device has low sensitivity 80% (95% CI 75% – 82%) and high specificity 91.8% (95% CI 85% – 92%) for detecting the abnormal ECG. The Positive Predictive Value (PPV) was 63.2% (95% CI 58.8% – 67.52%) and Negative Predictive Value (NVP) was 96.3% (95% CI 94.7% – 98.3%). This device demonstrates an ability to detect PVC and PAC (Sensitivity 71.4% (95% CI 66.4% - 76.4%) and 75% (95% CI 72%-78%), Specificity 97.8% (95% CI 95.8-99.8%) and 91.7% (95% CI 83.4%- 99.7%, respectively). The PPV of this device to detect PVC and PAC was 71.4% (95% CI 66.4%-76.4%) and 72.7%. (95% CI 68.7%-76.7%) The NPV of this device to detect PVC and PAC was 97.8% (95% CI 95.8%-99.85) and 98.9% (95% CI 98.1%-99.7%), respectively. This study found that the device to be a valuable diagnostic tool that has relatively low sensitivity but high specificity for diagnosing Abnormal ECG, PVC and PAC. According to the results of our study, we found that the device to be a valuable diagnostic tool that has relatively high sensitivity and specificity for diagnosing Abnormal ECG, PVC and PAC.

2021 ◽  
Vol 2 (1) ◽  

Background: Systematic cultures of drain tips or drainage fluids are commonly used by surgical teams for the early detection of Surgical Site Infection (SSI), even in the absence of clinical suspicion of infection. However, their prognostic values are controversial. Method: This was a prospective study of patients undergoing spine surgery at our institute during the study period. Patients already diagnosed with spine infection were excluded from the study. At the time of drain removal, the drain tip was cut and sent to microbiology laboratory for bacterial culture. All patients were treated with antimicrobial prophylaxis based on evidence-based guidelines and were monitored for at least 6 months after surgery for the development of Surgical Site Infection (SSI). SSI was defined according to Centers for Disease Control and Prevention criteria. Results: The study comprised of 183 patients including 85 males and 98 females. The rate of Surgical Site Infection in our study was 2.73 % (5 patients). Drain Tip Culture (DTC) was positive in 4 patients (2.18 %). Association of DTC with SSI was found to have high Specificity (98.31 %) and Negative Predictive Value (97.76 %) but low Sensitivity (20 %) and Positive Predictive Value (25 %). Conclusion: Culture of drain tip after spine surgery does not conclusively predict the presence or absence of surgical site infection. However, statistical significance was observed between drain tip culture and surgical site infection with high specificity, high negative predictive value, low sensitivity and low positive predictive value. Keywords: Drain tip culture; Spinal Surgery; Surgical site infection.


2020 ◽  
Vol 4 (Supplement_1) ◽  
Author(s):  
Federica Saponaro ◽  
Filomena Cetani ◽  
Laura Mazoni ◽  
Matteo Apicella ◽  
Marco Scalese ◽  
...  

Abstract The 4th International Workshop for the management of asymptomatic PHPT included, among the criteria for parathyroidectomy, the presence of hypercalciuria (dUCa> 400 mg/day) and increased biochemical stone risk profile. The aim of the present study was to evaluate the biochemical stone risk profile in 176 consecutive patients (143 females and 33 males) with asymptomatic PHPT. We recorded clinical and biochemical data, including 24 hours urinary measurements of the following parameters: volume and pH, creatinine, calcium, magnesium, sodium, potassium, ammonium, uric acid, oxalate, citrate, phosphate, inorganic sulphate and chloride and kidney ultrasound. In our cohort dUCa> 400mg/day showed a low sensitivity and positive predictive value (PPV) for nephrolithiasis with high specificity (46.2, 32.7, 73.0% respectively), while hypercalciuria by 4 mg/kg/bw (d-UCa>4mg/kg) had a high sensibility, with low PPV and specificity (79.5, 27.7, 40.1%) Daily hypomagnesuria (d-HypoMg), but not any other urinary parameter, was an independent predictor of nephrolithiasis in the univariate (OR 2.97 CI 1.27-7.09 P=0.014) and multivariate analyses adjusting for age, sex, BMI, and eGFR (OR 3.13 CI 1.17-8.42 P=0.02). d-HypoMg was relatively lower in the regression analysis with urinary calcium in patients with nephrolithiasis compared with those without. The mean ratio between (dUCa) and (dUMg) was higher in patients with nephrolithiasis compared with those without (4.6±2.0 vs 3.3±4.1; P<0.001). In the univariate and multivariate analyses the dUCa/dUMg ratio was a significant predictor of nephrolithiasis [OR 4.9 (2.3-10.5); P<0.001; OR 5.3 (2.4-11.6), P<0.001, respectively]. The AUC using the dUCa/dUMg ratio as variables was 0.69 (CI 0.60-0.79; P<0.0001). The best cut-off value, set at the highest Youden index, was equal to 4.0, with a sensitivity of 59.0% and a specificity of 77.4%. In patients with hypercalciuria (>400 mg/24-hour) dUMg was positively correlated with dUCa in those without nephrolithiasis (r=0.50, β=0.2, P=0.002) but not in those with nephrolithiasis (r=0.05, β= 0.014; P=0.8). In patients without hypercalciuria we found that hypomagnesuria remained a predictor of nephrolithiasis using either 400 mg/die (P=0.002, OR 5.12 (1.84-14.24) or 4 mg/kg bw (P=0.014, OR 6.24 (1.45-26.8). Moreover, the OR for nephrolithiasis improved using the combination of d-HypoMg with d-UCa>4mg/kg (OR 8.12, CI 1.92-34.18, P=0.004), but not with dUCa> 400mg/day. The current urinary calcium threshold of >400 mg/24-hour has a low sensitivity in detecting nephrolithiasis; our data suggest that sensitivity, specificity and positive predictive value could be improved including dUMg, dUCa/dUMg ratio and the combination of d-HypoMg with d-UCa>4mg/kg in the stone risk evaluation.


2021 ◽  
Vol 60 (6-7) ◽  
pp. 304-313
Author(s):  
Shailender Madani ◽  
Rohit Madani ◽  
Suchi Parikh ◽  
Ahila Manivannan ◽  
Wilma R. Orellana ◽  
...  

Our study aims to assess improvement with symptomatic treatment of pain-related functional gastrointestinal disorders (FGIDs) in a biopsychosocial construct and evaluate validity of Rome III criteria. Children with chronic abdominal pain diagnosed with an FGID or organic disease were followed for 1 year: 256/334 were diagnosed with an FGID and 78/334 were diagnosed with a possible organic disease due to alarm signs or not meeting Rome III criteria. After 1 year, 251 had true FGID and 46 had organic diseases. Ninety percent of FGID patients improved with symptomatic treatment over an average of 5.4 months. With a 95% confidence interval, Rome criteria predicted FGIDs with sensitivity 0.89, specificity 0.90, positive predictive value 0.98, and negative predictive value 0.59. We conclude that symptomatic treatment of pain-related FGIDs results in clinical improvement and could reduce invasive/expensive testing. Rome III criteria’s high specificity and positive predictive value suggest they can rule in a diagnosis of FGID.


Author(s):  
Teng Hoo ◽  
Ee Mun Lim ◽  
Mina John ◽  
Lloyd D’Orsogna ◽  
Andrew McLean-Tooke

Background Calculated globulin fraction is derived from the liver function tests by subtracting albumin from the total protein. Since immunoglobulins comprise the largest component of the serum globulin concentration, increased or decreased calculated globulins and may identify patients with hypogammaglobulinaemia or hypergammaglobulinaemia, respectively. Methods A retrospective study of laboratory data over 2.5 years from inpatients at three tertiary hospitals was performed. Patients with paired calculated globulins and immunoglobulin results were identified and clinical details reviewed. The results of serum electrophoresis testing were also assessed where available. Results A total of 4035 patients had paired laboratory data available. A calculated globulin ≤20 g/L (<2nd percentile) had a low sensitivity (5.8%) but good positive predictive value (82.5%) for hypogammaglobulinaemia (IgG ≤5.7 g/L), with a positive predictive value of 37.5% for severe hypogammaglobulinaemia (IgG ≤3 g/L). Paraproteins were identified in 123/291 (42.3%) of patients with increased calculated globulins (≥42 g/L) who also had a serum electrophoresis performed. Significantly elevated calculated globulin ≥50 g/L (>4th percentile) were seen in patients with either liver disease (37%), haematological malignancy (36%), autoimmune disease (13%) or infections (9%). Conclusions Calculated globulin is an inexpensive and easily available test that assists in the identification of hypogammaglobulinaemia or hypergammaglobulinaemia which may prompt further investigation and reduce diagnostic delays.


Author(s):  
Rakuhei Nakama ◽  
Ryo Yamamoto ◽  
Yoshimitsu Izawa ◽  
Keiichi Tanimura ◽  
Takashi Mato

Abstract Background Unnecessary whole-body computed tomography (CT) may lead to excess radiation exposure. Serum D-dimer levels have been reported to correlate with injury severity. We examined the predictive value of serum D-dimer level for identifying patients with isolated injury that can be diagnosed with selected-region CT rather than whole-body CT. Methods This single-center retrospective cohort study included patients with blunt trauma (2014–2017). We included patients whose serum D-dimer levels were measured before they underwent whole-body CT. “Isolated” injury was defined as injury with Abbreviated Injury Scale (AIS) score ≤ 5 to any of five regions of interest or with AIS score ≤ 1 to other regions, as revealed by a CT scan. A receiver operating characteristic curve (ROC) was drawn for D-dimer levels corresponding to isolated injury; the area under the ROC (AUROC) was evaluated. Sensitivity, specificity, positive predictive value, and negative predictive value were calculated for several candidate cut-off values for serum D-dimer levels. Results Isolated injury was detected in 212 patients. AUROC was 0.861 (95% confidence interval [CI]: 0.815–0.907) for isolated injury prediction. Serum D-dimer level ≤ 2.5 μg/mL was an optimal cutoff value for predicting isolated injury with high specificity (100.0%) and positive predictive value (100.0%). Approximately 30% of patients had serum D-dimer levels below this cutoff value. Conclusion D-dimer level ≤ 2.5 μg/mL had high specificity and high positive predictive value in cases of isolated injury, which could be diagnosed with selected-region CT, reducing exposure to radiation associated with whole-body CT.


Author(s):  
Dagmar Lagerberg ◽  
Margaretha Magnusson ◽  
Claes Sundelin

Abstract Background: The Edinburgh Postnatal Depression Scale (EPDS) is widely used in early child health care. This study examined the appropriateness of the recommended EPDS cut-off score 11/12. Methods: Two main analyses were performed: 1. Associations between EPDS scores and maternal health behaviour, stress, life events, perceived mother-child interaction quality and child behaviour. 2. Screening parameters of the EPDS, i.e., sensitivity, specificity and positive predictive value. EPDS scores were available for 438 mothers and maternal questionnaires for 361 mothers. Results: Already in the EPDS score intervals 6–8 and 9–11, there were notable adversities, according to maternal questionnaires, in stress, perceived quality of mother-child interaction, perceived child difficultness and child problem behaviours. Using maternal questionnaire reports about sadness/distress postpartum as standard, the recommended EPDS cut-off score 11/12 resulted in a very low sensitivity (24%). The cut-off score 6/7 yielded a sensitivity of 61%, a specificity of 82% and a positive predictive value of 61%. Conclusions: In terms of both clinical relevance and screening qualities, an EPDS cut-off score lower than 11/12 seems recommendable.


Author(s):  
Lijuan Wang ◽  
Hong Lv ◽  
Guojun Zhang

Background The study aimed to evaluate a fully automated chemiluminescent immunoassay and compared it with a quantitative RNA assay and anti-HCV assay to verify the utility of this automated Ag assay as an alternative method for hepatitis C diagnosis. Methods A total of 229 serum samples previously tested for anti-HCV concentrations by the Architect Anti-HCV assay, were selected for HCV RNA testing by real time RT-PCR kit (Shanghai ZJ Bio-Tec Co., Ltd) and 125 specimens were tested for HCV Ag by the Architect HCV core Antigen kit. Results The log10 HCVAg and HCV RNA concentrations were highly correlated [ r = 0.834); with HCV RNA as the comparator test, HCVAg had 100% specificity, 100% positive predictive value (PPV) and 94.8% sensitivity. We found 1 pg/mL of total HCV core Ag is equivalent to approximately 6607HCV RNA international units (IU)/mL. Receiver operator characteristic curve analysis showed that the area under the curve of HCV core Ag (0.989) was greater than HCV Ab (0.871). HCV Ag concentrations and RNA-to-Ag ratio of the groups for HCV RNA concentrations ≤105 and >105 IU/mL were both significantly different from each other ( P < 0.05). Conclusion The Architect HCV core Ag assay may be an alternative method for hepatitis C diagnosis, performed on the same analytical platform and sample as the anti-HCV assay, shortening the diagnostic window period, demonstrating good correlation with HCV RNA assay with high specificity and positive predictive value.


2009 ◽  
Vol 25 (5) ◽  
pp. 1017-1024 ◽  
Author(s):  
Carolina Castro Martins ◽  
Loliza Chalub ◽  
Ynara Bosco Lima-Arsati ◽  
Isabela Almeida Pordeus ◽  
Saul Martins Paiva

The aim of this study was to assess agreement in the diagnosis of dental fluorosis performed by a standardized digital photographic method and a clinical examination (gold standard). 49 children (aged 7-9 years) were clinically evaluated by a trained examiner for the assessment of dental fluorosis. Central incisors were evaluated for the presence or absence of dental fluorosis and were photographed with a digital camera. Photographs were presented to three pediatric dentists, who examined the images. Data were analyzed using Cohen's kappa and validity values. Agreement in the diagnosis performed by the photographic method and clinical examination was good (0.67) and accuracy was 83.7%. The prevalence of dental fluorosis was reported to be higher in the clinical examination (49%) compared with the photographic method (36.7%). The photographic method presented higher specificity (96%) than sensitivity (70.8%), a positive predictive value (PPV) of 94.4% and a negative predictive value (NPV) of 77.4%. The diagnosis of dental fluorosis performed using the photographic method presented high specificity and PPV, which indicates that the method is reproducible and reliable for recording dental fluorosis.


2012 ◽  
Vol 2 (2) ◽  
pp. 51 ◽  
Author(s):  
Krystal A.T. Gayle ◽  
Marshall K. Tulloch-Reid ◽  
Rainford J. Wilks ◽  
Trevor S. Ferguson

This study evaluated the ability of the slipping slipper sign (defined as unknowingly losing a slipper while walking) to identify diabetic neuropathy in Jamaican patients. A single question was used to ascertain the presence of the slipping slipper sign (SSS) among 69 patients attending a diabetes clinic. Nurses assessed pain, vibration and pressure perception among the same patients in order to detect diabetic neuropathy. The sensitivity, specificity and positive predictive value for the SSS were calculated. Eight participants (men=5, women=3) reported positive SSS. The SSS had a sensitivity of 28.6%, specificity of 100% and positive predictive value (PPV) 100% for neuropathy on at least one of the three tests. These findings indicate that the SSS has high specificity and PPV for diabetic neuropathy but the sensitivity is low. The sign may be a useful adjuvant to conventional methods of screening for severe neuropathy


2019 ◽  
Vol 2019 ◽  
pp. 1-7 ◽  
Author(s):  
Konuralp Yakar

Aim. To compare the clinical performance of the Spot Vision Screener used to detect amblyopia risk factors (ARFs) in children before and after induction of cycloplegia; the children were referred because they met the screening criteria of the American Association for Pediatric Ophthalmology and Strabismus (AAPOS). Methods. The Spot Vision Screener and a standard autorefractometer were used to examine 200 eyes of 100 children aged 3–10 years, before and after cycloplegia induction, in terms of ARFs. Sensitivity, specificity, and positive and negative predictive values for the detection of significant refractive errors were measured using the AAPOS referral criteria. It was explored that Spot Screener data were affected by cycloplegia. The extent of agreement between cycloplegic/noncycloplegic photoscreening data and cycloplegic autorefraction measurements was assessed using Wilcoxon and Spearman correlation analyses. Results. The Spot’s sensitivity was improved from 60.9% to 85.3% and specificity from 94.9% to 87.4% with cycloplegia compared to cycloplegic standard autorefractometer results. The positive predictive value of Spot was 75.7%, and the negative predictive value was 90.4% without cycloplegia. With cycloplegia, the positive predictive value of Spot was 63.6% and the negative predictive value was 95.8%. Conclusions. The Spot Screener afforded moderate sensitivity and high specificity prior to cycloplegia. The sensitivity and negative predictive value improved after induction of cycloplegia. Examiners should be aware of the effects of cycloplegia on their findings.


Sign in / Sign up

Export Citation Format

Share Document