scholarly journals Effects of Different Fluting Medium Geometries on Von-Mises Stress and Deformation in Single Fluted Board: A Three-Dimensional Finite Element Analysis

Author(s):  
Mohd Salahuddin Mohd Basri ◽  
Mohd Zuhair Mohd Nor ◽  
Rosnah Shamsudin ◽  
Intan Syafinaz Mohamed Amin Tawakkal ◽  
Nur Hamizah Abdul Ghani ◽  
...  

Paperboard box produced in large volume for packaging purpose either to pack light or heavy product. When a heavy product is packed, high strength and structural stability against compression and deformation of the paperboard box are demanded. This paper investigates the effects of different shape of fluting mediums on the von Mises stress and deformation using finite element analysis (FEA) tool. Solidworks and ANSYS software were used to design a 3-D model and perform static structural analysis, respectively. The result from the analysis and simulation revealed that common s-shape geometry experienced the lowest von Mises stress and deformation. Honeycomb geometry experienced the highest von Mises stress of 0.19576 MPa while triangle fluting medium recorded the highest deformation at 1.8695E-4mm.

2020 ◽  
Vol 28 (6) ◽  
pp. 603-613 ◽  
Author(s):  
Efe Can Sivrikaya ◽  
Mehmet Sami Guler ◽  
Muhammed Latif Bekci

BACKGROUND: Zirconia has become a popular biomaterial in dental implant systems because of its biocompatible and aesthetic properties. However, this material is more fragile than titanium so its use is limited. OBJECTIVES: The aim of this study was to compare the stresses on morse taper implant systems under parafunctional loading in different abutment materials using three-dimensional finite element analysis (3D FEA). METHODS: Four different variations were modelled. The models were created according to abutment materials (zirconia or titanium) and loading (1000 MPa vertical or oblique on abutments). The placement of the implants (diameter, 5.0 × 15 mm) were mandibular right first molar. RESULTS: In zirconia abutment models, von Mises stress (VMS) values of implants and abutments were decreased. Maximum and minimum principal stresses and VMS values increased in oblique loading. VMS values were highest in the connection level of the conical abutments in all models. CONCLUSIONS: Using conical zirconia abutments decreases von Mises stress values in abutments and implants. However, these values may exceed the pathological limits in bruxism patients. Therefore, microfractures may be related to the level of the abutment.


2020 ◽  
Vol 899 ◽  
pp. 94-102
Author(s):  
Nur Faiqa Ismail ◽  
Muhammmad Aiman Firdaus Bin Adnan ◽  
Solehuddin Shuib ◽  
Nik Ahmad Hambali Nik Abd Rashid

External fixator has played an important role in repairing fractured ankle bone. This surgery is done due to the several factors which are the bone is not normal position or has broken into several pieces. The external fixator will help the broken bone to grow and remodel back to the original appearance. However, there are some issues regarding to the stability of this fixation. Improper design and material are the major factor that decreased the stability since it is related to the deformation of the external fixator to hold the bone fracture area. This study aims to design a stable structure for constructing delta frame ankle external fixator to increase the stability of the fixation. There are two designs of external fixator with two types of material used in this present study. Both external fixators with different materials are analyzed in terms of von Mises stress and deformation by using a conventional Finite Element Analysis software; ANSYS Workbench V15. The result obtained shows the Model 1 with stainless steel has less stress and deformation distributions compared to the Model 2. Hence, by using Model 1 as the external fixator, the stability of the fixation can be increased.


2020 ◽  
Vol 46 (1) ◽  
pp. 3-12
Author(s):  
Ji-Hyeon Oh ◽  
Young-Seong Kim ◽  
Joong Yeon Lim ◽  
Byung-Ho Choi

The all-on-4 concept, which is used to rehabilitate edentulous patients, can present with mechanical complications such as screw loosening and fracture. The purpose of this study was to evaluate the stress patterns induced in the prosthetic screws by the different prosthetic screw and abutment designs in the all-on-4 concept using finite element analysis. Von Mises stress values on 6 groups of each screw type, including short and narrow screw, short abutment; short and wide screw, short abutment; long and wide screw, short abutment; short and narrow screw, long abutment; short and wide screw, long abutment; and long and wide screw, long abutment, were compared under a cantilever loading of 200 N that was applied on the farther posterior to the position of the connection between the distal implant and the metal framework. Posterior prosthetic screws showed higher stress values than anterior prosthetic screws. The stress values in posterior prosthetic screws decreased as the length and diameter increased. In conclusion, the long and wide screw design offers advantages in stress distribution when compared with the short and narrow design.


2015 ◽  
Vol 41 (2) ◽  
pp. 163-171 ◽  
Author(s):  
Gianpaolo Sannino

The aim of this work was to study the biomechanical behavior of an All-on-4 implant-supported prosthesis through a finite element analysis comparing 3 different tilt degrees of the distal implants. Three-dimensional finite element models of an edentulous maxilla restored with a prosthesis supported by 4 implants were reconstructed to carry out the analysis. Three distinct configurations, corresponding to 3 tilt degrees of the distal implants (15°, 30°, and 45°) were subjected to 4 loading simulations. The von Mises stresses generated around the implants were localized and quantified for comparison. Negligible differences in von Mises stress values were found in the comparison of the 15° and 30° models. From a stress-level viewpoint, the 45° model was revealed to be the most critical for peri-implant bone. In all the loading simulations, the maximum stress values were always found at the neck of the distal implants. The stress in the distal implants increased in the apical direction as the tilt degree increased. The stress location and distribution patterns were very similar among the evaluated models. The increase in the tilt degree of the distal implants was proportional to the increase in stress concentration. The 45° model induced higher stress values at the bone-implant interface, especially in the distal aspect, than the other 2 models analyzed.


Author(s):  
Yasufumi Kosugi ◽  
Makoto Hirota ◽  
Naohito Tamai ◽  
Hikaru Takasu ◽  
Toshinori Iwai ◽  
...  

This study was conducted to determine the most secure implant positioning on the marginally resected mandible to support a fixed complete denture through finite element analysis. Three or four implants were placed at near, middle, or far positions from the resected margin in a simulation model with a symmetrical marginal defect in the mandibular symphysis. The height of the residual bone was 5, 10, or 15 mm. The four possible implant patterns for 3 or 4 implants were defined as: (1) asymmetrically isolated position one to position two, (2) asymmetrically isolated position one to position three, (3) asymmetrically isolated with greater length position one to position two, and (4) two implants symmetrically positioned on each side of the defect. The von Mises stress in the resected and peri-implant bone with respect to the occlusal force was calculated. Initially, as the peri-implant bone stress around isolated implant at the near position was greater than at the middle and far positions regardless of the residual bone height, the near position was excluded. Second, the von Mises stress in the resected bone region was > 10 MPa when the isolated implant was at the far position, and it increased inversely depending on the bone height. However, the stress was < 10 MPa when the isolated implant was placed at the middle position regardless of the bone height, and it was significantly lower compared to the far position, and equivalent to the symmetrically positioned implants. Furthermore, the use of greater length implant reduced the peri-implant bone stress, which was even lower than that of the symmetrically positioned implants. These results suggest that the asymmetrically positioned three-implant-supported fixed denture, using a greater length isolated implant, placed neither too close to nor too far from the resected margin, can be an effective alternative to the symmetrically positioned four-implant-supported fixed denture.


2011 ◽  
Vol 1 (2) ◽  
pp. 55
Author(s):  
Özkan ADIGÜZEL ◽  
Sadullah KAYA ◽  
Senem YİĞİT ÖZER ◽  
Yalçın DEĞER ◽  
Emine GÖNCÜ BAŞARAN ◽  
...  

Aim: This study compared the stress distributions of endodontically treated tooth restored with carbon and titanium post during different loading conditions. Methodology: A 3-dimensional finite element model was created to represent an endodontically treated maxillary central incisor tooth with its supporting structures. Stress distribution and stress values were then calculated by considering the three dimensional von Mises stress criteria. Results: A 100-N static vertical occlusal load was applied on the node at the center of occlusal surface of the tooth. The von Mises stress values for carbon post model was on the coronal third and the cervical area of the root in the range of 353.149 and 13.878 MPa,  for titanium post model was 540.736 and 22.777 MPa. Conclusion: This study shows that the titanium post yields larger stresses than the carbon post.  How to cite this article: Adıgüzel Ö, Kaya S, Yiğit Özer S, Değer Y, Göncü Başaran E, Yavuz İ. Three-dimensional Finite Element Analysis of Endodontically Treated Tooth Restored with Carbon and Titanium Posts. Int Dent Res 2011;2:55-59. Linguistic Revision: The English in this manuscript has been checked by at least two professional editors, both native speakers of English.


2013 ◽  
Vol 07 (04) ◽  
pp. 484-491 ◽  
Author(s):  
Wagner Moreira ◽  
Caio Hermann ◽  
Jucélio Tomás Pereira ◽  
Jean Anacleto Balbinoti ◽  
Rodrigo Tiossi

ABSTRACT Objective: The purpose of this study was to evaluate the mechanical behavior of two different straight prosthetic abutments (one- and two-piece) for external hex butt-joint connection implants using three-dimensional finite element analysis (3D-FEA). Materials and Methods: Two 3D-FEA models were designed, one for the two-piece prosthetic abutment (2 mm in height, two-piece mini-conical abutment, Neodent) and another one for the one-piece abutment (2 mm in height, Slim Fit one-piece mini-conical abutment, Neodent), with their corresponding screws and implants (Titamax Ti, 3.75 diameter by 13 mm in length, Neodent). The model simulated the single restoration of a lower premolar using data from a computerized tomography of a mandible. The preload (20 N) after torque application for installation of the abutment and an occlusal loading were simulated. The occlusal load was simulated using average physiological bite force and direction (114.6 N in the axial direction, 17.1 N in the lingual direction and 23.4 N toward the mesial at an angle of 75° to the occlusal plan). Results: The regions with the highest von Mises stress results were at the bottom of the initial two threads of both prosthetic abutments that were tested. The one-piece prosthetic abutment presented a more homogeneous behavior of stress distribution when compared with the two-piece abutment. Conclusions: Under the simulated chewing loads, the von Mises stresses for both tested prosthetic-abutments were within the tensile strength values of the materials analyzed which thus supports the clinical use of both prosthetic abutments.


2014 ◽  
Vol 607 ◽  
pp. 713-716
Author(s):  
Wen Liang Tang ◽  
Chun Yue Huang ◽  
Tian Ming Li ◽  
Ying Liang ◽  
Guo Ji Xiong ◽  
...  

In this paper, ANSYS-LSDYNA simulation software is used to build the three-dimensional finite element model of the ball bond and to get the Von Mises stress. The change of stress about the bump is researched which base on the model in different bonding pressure, bonding power and bonding time. The result show that: The stress increase with bonding pressure increase within a certain bonding pressure range, and then the stress will maintain a table number, however, the stress will continue to increase when the bonding pressure reach a certain value; increasing the bonding power, the area of lager stress will grow; prolonging the bonding time, the stress of the pad will increase with time, but when time increase to a certain value, the stress of the pad will not increase over time.


Author(s):  
Mateus Favero Barra Grande ◽  
Marcelo Lucchesi Teixeira ◽  
André Antônio Pelegrine ◽  
Guilherme Da Rocha Scalzer Lopes ◽  
Julio Ferraz Campos ◽  
...  

The effect of the different dental implants positioning region on the stress performance of the implant-supported prosthesis is not yet clear. This study evaluated the dental treatment with six dental implants in three different models and three different occlusal loading conditions, in terms of the biomechanical response of implants, prosthetic screw and maxilla, using three-dimensional finite element analysis. The finite element models were modelled containing external hexagon implants, as well as a Cobalt-Chromium superstructure. Three types of loads were applied: in the area of ​​the central incisors, first premolar and in the second molars. For the finite element simulations, the von-Mises stress peaks in the implant and in the surrounding cortical bone were analyzed. All recorded results reported higher values ​​for the implant-supported prosthesis in group C compared to the groups A and B. The highest stress values, ​​regardless the evaluated model, was in the prosthesis in group C and in screws, the smallest were in group A.


Sign in / Sign up

Export Citation Format

Share Document