Near-infrared optical-feedback linear cavity-enhanced absorption spectroscopy

2021 ◽  
Vol 29 (5) ◽  
pp. 933-939
Author(s):  
Fei XU ◽  
◽  
Xiao-bin ZHOU ◽  
Zheng-bo LIU ◽  
Gang ZHAO ◽  
...  
2021 ◽  
Author(s):  
Gang Zhao ◽  
Jianfei Tian ◽  
Weiguang Ma ◽  
Adam Fleisher ◽  
Suotang Jia

2016 ◽  
Vol 8 (4) ◽  
pp. 110 ◽  
Author(s):  
Lucile Rutkowski ◽  
Alexandra C. Johansson ◽  
Damir Valiev ◽  
Amir Khodabakhsh ◽  
Arkadiusz Tkacz ◽  
...  

We report broadband detection of OH in a premixed CH4/air flat flame at atmospheric pressure using cavity-enhanced absorption spectroscopy based on an Er:fiber femtosecond laserand a Fourier transform spectrometer.By taking ratios of spectra measured at different heights above the burner we separate twenty OH transitions from the largely overlapping water background. Weretrieve from fits to the OH lines the relative variation of the OH concentration and flame temperature with height above the burner and compare them with 1-D simulations of the flamestructure. Full Text: PDF ReferencesG. Meijer, M. G. Boogaarts, R. T. Jongma, D. H. Parker and A. M. Wodtke, "Coherent cavity ring down spectroscopy", Chem. Phys. Lett. 217, 1, 112 (1994). CrossRef S. Cheskis, I. Derzy, V. A. Lozovsky, A. Kachanov and D. Romanini, "Cavity ring-down spectroscopy of OH radicals in low pressure flame", Appl. Phys. B 66, 3, 377 (1998). CrossRef X. Mercier, E. Therssen, J. F. Pauwels and P. Desgroux, "Cavity ring-down measurements of OH radical in atmospheric premixed and diffusion flames.: A comparison with laser-induced fluorescence and direct laser absorption", Chem. Phys. Lett. 299, 1, 75 (1999). CrossRef J. Scherer, D. Voelkel and D. Rakestraw, "Infrared cavity ringdown laser absorption spectroscopy (IR-CRLAS) in low pressure flames", Appl. Phys. B 64, 6, 699 (1997). CrossRef R. Peeters, G. Berden and G. Meijer, "Near-infrared cavity enhanced absorption spectroscopy of hot water and OH in an oven and in flames", Appl. Phys. B 73, 1, 65 (2001). CrossRef T. Aizawa, "Diode-laser wavelength-modulation absorption spectroscopy for quantitative in situ measurements of temperature and OH radical concentration in combustion gases", Appl. Opt. 40, 27, 4894 (2001). CrossRef B. Löhden, S. Kuznetsova, K. Sengstock, V. M. Baev, et al., "Fiber laser intracavity absorption spectroscopy for in situ multicomponent gas analysis in the atmosphere and combustion environments", Appl. Phys. B 102, 2, 331 (2011). CrossRef A. Matynia, M. Idir, J. Molet, C. Roche, et al., "Absolute OH concentration profiles measurements in high pressure counterflow flames by coupling LIF, PLIF, and absorption techniques", Appl. Phys. B 108, 2, 393 (2012). CrossRef R. S. Watt, T. Laurila, C. F. Kaminski and J. Hult, "Cavity Enhanced Spectroscopy of High-Temperature H2O in the Near-Infrared Using a Supercontinuum Light Source", Appl. Spectrosc. 63, 12, 1389 (2009). CrossRef C. Abd Alrahman, A. Khodabakhsh, F. M. Schmidt, Z. Qu and A. Foltynowicz, "Cavity-enhanced optical frequency comb spectroscopy of high-temperature H2O in a flame", Opt. Express 22, 11, 13889 (2014). CrossRef A. Foltynowicz, P. Maslowski, A. J. Fleisher, B. J. Bjork and J. Ye, "Cavity-enhanced optical frequency comb spectroscopy in the mid-infrared application to trace detection of hydrogen peroxide", Appl. Phys. B 110, 2, 163 (2013). CrossRef Z. Qu, R. Ghorbani, D. Valiev and F. M. Schmidt, "Calibration-free scanned wavelength modulation spectroscopy ? application to H2O and temperature sensing in flames", Opt. Express 23, 12, 16492 (2015). CrossRef L. Rutkowski, A. Khodabakhsh, A. C. Johansson, D. M. Valiev, et al., "Measurement of H2O and OH in a Flame by Optical Frequency Comb Spectroscopy", CLEO: Science and Innovations SW4H.8 (2016). CrossRef L. S. Rothman, I. E. Gordon, Y. Babikov, A. Barbe, et al., "The HITRAN2012 molecular spectroscopic database", J. Quant. Spectrosc. Radiat. Transf. 130, 4 (2013). CrossRef


The Analyst ◽  
2009 ◽  
Vol 134 (11) ◽  
pp. 2220 ◽  
Author(s):  
W. Denzer ◽  
M. L. Hamilton ◽  
G. Hancock ◽  
M. Islam ◽  
C. E. Langley ◽  
...  

2017 ◽  
Vol 10 (5) ◽  
pp. 1803-1812 ◽  
Author(s):  
Irène Ventrillard ◽  
Irène Xueref-Remy ◽  
Martina Schmidt ◽  
Camille Yver Kwok ◽  
Xavier Faïn ◽  
...  

Abstract. We present the first comparison of carbon monoxide (CO) measurements performed with a portable laser spectrometer that exploits the optical-feedback cavity-enhanced absorption spectroscopy (OF-CEAS) technique, against a high-performance automated gas chromatograph (GC) with a mercuric oxide reduction gas detector (RGD). First, measurements of atmospheric CO mole fraction were continuously collected in a Paris (France) suburb over 1 week. Both instruments showed an excellent agreement within typically 2 ppb (part per billion in volume), fulfilling the World Meteorological Organization (WMO) recommendation for CO inter-laboratory comparison. The compact size and robustness of the OF-CEAS instrument allowed its operation aboard a small aircraft employed for routine tropospheric air analysis over the French Orléans forest area. Direct OF-CEAS real-time CO measurements in tropospheric air were then compared with later analysis of flask samples by the gas chromatograph. Again, a very good agreement was observed. This work establishes that the OF-CEAS laser spectrometer can run unattended at a very high level of sensitivity ( <  1 ppb) and stability without any periodic calibration.


Sign in / Sign up

Export Citation Format

Share Document