Experimental study on the toxicity and the local and systemic tolerability of gemcitabine after topical treatment of the rabbit bladder

2004 ◽  
Author(s):  
M. Matera ◽  
G. Costantino ◽  
G. Clementi ◽  
L. Lempereur ◽  
D. Vasta ◽  
...  
2018 ◽  
Vol 7 (3) ◽  
pp. 43-46 ◽  
Author(s):  
R. I. Yakubovskaya ◽  
A. A. Pankratov ◽  
E. V. Filonenko ◽  
E. A. Lukyanets ◽  
V. I. Ivanova-Radkevich ◽  
...  

A comparative experimental study of the specific activity of drugs based on 5-aminolevulinic acid (5-ALA) and its hexyl ester (5-ALA HE) was carried out. Their ability to induce the synthesis of photoactive protoporphyrin IX in the healthy tissues of the rabbit bladder when instilling the drug solutions at various concentrations has been estimated. It was shown that 5-ALA HE results in the induction and accumulation of PPIX in the rabbit bladder epithelium at much lower concentrations than 5-ALA. Thus, a significant increase in the fluorescence intensity in comparison with the control was achieved by instillation of 5-ALA HE solution in the rabbit’ bladder at a concentration of only 0.0001% (fluorescence intensity 2.20±0.60 a.u.), and for 5-ALA – only when using a solution at a concentration of 0.3% (fluorescence intensity 2.60±1.02 a.u.).


2013 ◽  
Vol 19 (6) ◽  
pp. 464-467 ◽  
Author(s):  
Li-li Lu ◽  
Ping Wan ◽  
Li-zhen Li ◽  
Mei-jun Zhao ◽  
Jia-yao Hu ◽  
...  

Author(s):  
Norio Baba ◽  
Norihiko Ichise ◽  
Syunya Watanabe

The tilted beam illumination method is used to improve the resolution comparing with the axial illumination mode. Using this advantage, a restoration method of several tilted beam images covering the full azimuthal range was proposed by Saxton, and experimentally examined. To make this technique more reliable it seems that some practical problems still remain. In this report the restoration was attempted and the problems were considered. In our study, four problems were pointed out for the experiment of the restoration. (1) Accurate beam tilt adjustment to fit the incident beam to the coma-free axis for the symmetrical beam tilting over the full azimuthal range. (2) Accurate measurements of the optical parameters which are necessary to design the restoration filter. Even if the spherical aberration coefficient Cs is known with accuracy and the axial astigmatism is sufficiently compensated, at least the defocus value must be measured. (3) Accurate alignment of the tilt-azimuth series images.


Author(s):  
F.E. Hossler ◽  
M.I. McKamey ◽  
F.C. Monson

A comprehensive study of the microvasculature of the normal rabbit bladder, revealed unusual "capillary glomeruli" along the lateral walls. Here they are characterized as hemal lymph nodes using light microscopy, SEM, TEM, ink injection, and vascular casting.Bladders were perfused via a cannula placed in the abdominal aorta with either 2% glutaraldehyde in 0.1M cacodylate buffer (pH 7.4) for fixation, 10% India ink in 0.9% saline and 0.1M phosphate (pH 7.4) for vessel tracing, or resin (Mercoximethylmethacrylate: catalyst, 4:1:0.3; Ladd Research Industries) for vascular corrosion casting. Infusion pressure was 100mm Hg. Fixed tissue was sectioned from epon-araldyte resin, and stained with toluidine blue for light microscopy, and lead and uranium for TEM. Ink injected tissue was photographed directly from saline-filled bladders illuminated from below. Resin-filled tissue was macerated in 5% KOH and distilled water. Casts were critical point dried, sputter coated with goldpalladium, and examined by routine SEM at 10 KV.


1962 ◽  
Vol 5 (4) ◽  
pp. 387-394 ◽  
Author(s):  
Bruce Quarrington ◽  
Jerome Conway ◽  
Nathan Siegel
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document