One-Stage External Fixation Using a Locking Plate: Experience in 116 Tibial Fractures

Orthopedics ◽  
2015 ◽  
Vol 38 (8) ◽  
pp. 494-497 ◽  
Author(s):  
Jingwei Zhang ◽  
Nabil A. Ebraheim ◽  
Ming Li ◽  
Xianfeng He ◽  
Jiayong Liu
2021 ◽  
Author(s):  
Dejan Blažević ◽  
Janoš Kodvanj ◽  
Petra Adamović ◽  
Dinko Vidović ◽  
Zlatko Trobonjača ◽  
...  

Abstract BackgroundGood clinical outcomes for locking plates as an external fixator to treat tibial fractures have been reported. However, external locking plate fixation is still generally rarely performed. This study aimed to compare the stability of external locking plate fixator with that of conventional external fixator for extraarticular proximal tibial fractures, using finite element analysis. MethodsThree models were constructed: (1) external locking plating of proximal tibial fracture with lateral proximal tibial locking plate and 5-mm screws (ELP), (2) conventional external fixation of proximal tibial fracture with an 11-mm rod and 5-mm Schanz screws (EF-11), and (3) conventional external fixation of proximal tibial fracture with a 7-mm rod and 5-mm Schanz screws (EF-7). The stress distribution, displacement at the fracture gap, and stiffness of the three finite element models at 30-, 40-, 50-, and 60-mm plate–rod offset from the lateral surface of the lateral condyle of the tibia were determined. ResultsThe conventional external fixator showed higher stiffness than did the external locking plate fixator. In all models, the stiffness decreased as the distance of the plate–rod from the bone surface increased. The maximum stiffness was 121.06 N/mm in the EF-11 model with 30-mm tibia–rod offset. In the EF-7 model group, the maximum stiffness was 40.00 N/mm in the model with 30-mm tibia–rod offset. In the ELP model group, the maximum stiffness was 35.79 N/mm in the model with 30-mm tibia–plate offsetConclusionsExternal locking plate fixation is more flexible than conventional external fixation, which can influence secondary bone healing. External locking plate fixation requires the placement of the plate as close as possible to the skin, which allow low-profile design, because the increased distance of the plate from bone can be too flexible for bone healing.


2020 ◽  
Vol 48 (4) ◽  
pp. 030006052092040
Author(s):  
Yao Lu ◽  
Teng Ma ◽  
Cheng Ren ◽  
Zhong Li ◽  
Liang Sun ◽  
...  

Objective To evaluate the effectiveness of bone transport involving circular external fixation and locking plate application for the treatment of segmental tibial defects. Methods A retrospective review of 12 patients with segmental tibial defects who underwent bone transport with circular external fixation and locking plate application. We evaluated external fixation time, external fixation index, time to achieve union, and complications. Clinical results were assessed using the Association for the Study and Application of the Methods of Ilizarov (ASAMI) score. Generic health-related outcome was assessed using the 36-Item Short-Form Health Survey questionnaire (SF-36). Results The mean follow-up was 25.8 months, and the mean defect size was 6.7 cm. All of the patients achieved union at the distraction callus and docking site. The average external fixation time was 299.5 days. The mean external fixation index was 16.5 days/cm, and the mean healing index was 44.9 days/cm. The functional outcomes were excellent in eight cases and good in four. The average SF-36 score was 92. Conclusion Bone transport with external fixation and locking plate application may be a promising method for the treatment of segmental tibial defects.


2021 ◽  
Vol 7 (1) ◽  
Author(s):  
Caroline B. Hing ◽  
Elizabeth Tutton ◽  
Toby O. Smith ◽  
Molly Glaze ◽  
Jamie R. Stokes ◽  
...  

Abstract Background Segmental tibial fractures are fractures in two or more areas of the tibial diaphysis resulting in a separate intercalary segment of the bone. Surgical fixation is recommended for patients with segmental tibial fractures as non-operative treatment outcomes are poor. The most common surgical interventions are intramedullary nailing (IMN) and circular frame external fixation (CFEF), but evidence about which is better is of poor quality. An adequately powered randomised controlled trial (RCT) to determine optimum treatment is required. STIFF-F aimed to assess the feasibility of a multicentre RCT comparing IMN with CFEF for segmental tibial fracture. Methods STIFF-F was a mixed-methods feasibility study comprising a pilot RCT conducted at six UK Major Trauma Centres, qualitative interviews drawing on Phenomenology and an online survey of rehabilitation. The primary outcome was recruitment rate. Patients, 16 years and over, with a segmental tibial fracture (open or closed) deemed suitable for IMN or CFEF were eligible to participate. Randomisation was stratified by site using random permuted blocks of varying sizes. Participant or assessor blinding was not possible. Interviews were undertaken with patients about their experience of injury, treatment, recovery and participation. Staff were interviewed to identify contextual factors affecting trial processes, their experience of recruitment and the treatment pathway. An online survey was developed to understand the rehabilitation context of the treatments. Results Eleven patients were screened and three recruited to the pilot RCT. Nineteen staff and four patients participated in interviews, and 11 physiotherapists responded to the survey. This study found the following: (i) segmental tibial fractures were rarer than anticipated, (ii) the complexity of the injury, study setup times and surgeon treatment preferences impeded recruitment, (iii) recovery from a segmental tibial fracture is challenging, and rehabilitation protocols are inconsistent and (iv) despite the difficulty recruiting, staff valued this research question and strived to find a way forward. Conclusion The proposed multicentre RCT comparing IMN with CFEF is not feasible. This study highlighted the difficulty of recruiting patients to an RCT of a complex rare injury over a short time period. Trial registration The study was registered with the International Standard Randomised Controlled Trials Number Registry: ISRCTN11229660


2013 ◽  
Vol 8 (2) ◽  
pp. 67-75 ◽  
Author(s):  
J. C. Goslings ◽  
Monique M. J. Walenkamp ◽  
Abdelali Bentohami ◽  
M. Suzan H. Beerekamp ◽  
Rolf W. Peters ◽  
...  

2016 ◽  
Vol 19 (2) ◽  
pp. 104-108 ◽  
Author(s):  
Jing-Wei Zhang ◽  
Nabil A. Ebraheim ◽  
Ming Li ◽  
Xian-Feng He ◽  
Joshua Schwind ◽  
...  

2015 ◽  
Vol 23 (2) ◽  
pp. 126-130 ◽  
Author(s):  
Nirmal Tejwani ◽  
David Polonet ◽  
Philip R. Wolinsky

2007 ◽  
Vol 89-B (2) ◽  
pp. 265-272 ◽  
Author(s):  
J. Ristiniemi ◽  
T. Flinkkilä ◽  
P. Hyvönen ◽  
M. Lakovaara ◽  
H. Pakarinen ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document