The 'Study on Nuclear Data by Using a High Intensity Pulsed Neutron Source for Advanced Nuclear System' Nuclear Data Project and the Characteristics of the Neutron Beam Line for the Capture Cross Section Experiments at J-PARC

2011 ◽  
Vol 59 (2(3)) ◽  
pp. 1781-1784 ◽  
Author(s):  
K. Kino ◽  
Y. Kiyanagi ◽  
M. Furusaka ◽  
F. Hiraga ◽  
T. Kamiyama ◽  
...  
2012 ◽  
Vol 1 (1) ◽  
pp. 21-25 ◽  
Author(s):  
J.C. Chow ◽  
F.P. Adams ◽  
D. Roubstov ◽  
R.D. Singh ◽  
M.B. Zeller

Recent cross-section measurements on gadolinium have raised concerns over the accuracy of moderator poison reactivity coefficient calculations. Measurements have been made at the ZED-2 (Zero Energy Deuterium) critical facility, Chalk River Laboratories, AECL, to study the reactivity effect of gadolinium in the moderator. Since the neutron capture cross-section of boron is well known, measurements were also made with boron to provide calibration data for measurements with gadolinium. The measurements have been used to quantify the bias of the reactivity effect in full-core simulations of ZED-2 using MCNP, a neutron transport code used extensively for simulations of nuclear systems, along with the ENDF/B-VII.0 cross-section data. The results showed a bias of -0.41 ± 0.07 mk/ ppm, or -2.1% ± 0.3%, given a reactivity worth of -20.1 mk/ppm for gadolinium. Additional simulations also show that the gadolinium neutron capture cross-section has been over-corrected, relative to previous evaluations, in a beta version of ENDF/B VII.1, which incorporates the Leinweber data.


2020 ◽  
Vol 239 ◽  
pp. 13002
Author(s):  
Gerald Rimpault ◽  
Gilles Noguère ◽  
Cyrille de Saint Jean

The objective of this work is to revisit integral data assimilation for a better prediction of the characteristics of SFR cores. ICSBEP, IRPhE and MASURCA critical masses, PROFIL irradiation experiments and the FCA-IX experimental programme (critical masses and spectral indices) with well-mastered experimental technique have been used. As calculations are performed without modelling errors (with as-built geometries) and without approximations with the TRIPOLI4 MC code, highly reliable C/E are achieved. Assimilation results suggest a 2.5% decrease for 238U capture from 3 keV to 60 keV, and a 4-5% decrease for 238U inelastic in the plateau region. For this energy range, uncertainties are respectively reduced to 1-2% and to 2-2.5% for 238U capture and 238U inelastic respectively. The increase trends on 239Pu capture cross section of around 3% in the [2 keV-100 keV] energy range come from a low PROFIL 240Pu/239Pu ratio C/E. For 240Pu capture cross section, the increase trend of around 4% in the [3 keV-100 keV] energy range goes in the same direction as the recent ENDF/B.VIII evaluation though at a much lower level. The nuclear data uncertainty associated to SFR ASTRID critical mass is reduced to 470 pcm.


2019 ◽  
Vol 9 (1) ◽  
pp. 28-33
Author(s):  
Manh Dung Ho ◽  
Lathdavong Phonesavanh

Nuclear data for the k0-based neutron activation analysis (k0-NAA) including: k0-factors – combination of nuclear constants (atomic mass, isotopic abundance, gamma-ray yield and thermal neutron capture cross section); Q0 – the ratio of the resonance integral to thermal neutron capture cross section; and Er – effective resonance energy, along with the related nuclear data are presented and evaluated in the presentation. Accuracy and capability of k0-NAA depends considerably on the reliability of the above mentioned nuclear data. In general, the evaluation of nuclear data is essential and necessary in the field of nuclear science and technology, and this work is conducted by the nuclear data centers on the world as well as the research institutions where the nuclear data are usedfor R&D. Therefore, the evaluation of the nuclear data used in k0-NAA should also be performed so that some of data may no longer be appropriate should be redetermined. The evaluation of nuclear data in k0-NAA would contribute to the improvement of accuracy and reliability of the method, moreover, it would also contribute to the establishment a nuclear database in Vietnam in the future.


2019 ◽  
Vol 211 ◽  
pp. 03001
Author(s):  
Gerald Rimpault ◽  
Virginie Huy ◽  
Gilles Noguère

Nuclear data evaluations on major actinides can be improved by integral data assimilation. Appropriate integral measurements with reliable experimental techniques have been selected such as ICSBEP, IRPhE and MASURCA critical masses, PROFIL irradiation experiments and the FCAIX experimental programme (critical masses and spectral indices). Highly reliable analyses are possible with the use of as-built geometries calculated with the TRIPOLI4 Monte Carlo code. The C/E values have been used in an integral data assimilation solving the Bayes equation. The trends on the JEFF3.1.1 235U capture cross section are quite consistent with recent differential measurements. Assimilation results suggest up to a 2.5% decrease for 238U capture from 3 keV to 60 keV, and a 4-5% decrease for 238U inelastic in the plateau region. For this energy range, uncertainties are respectively reduced from 3-4 to 1-2% and from 6-9% to 2-2.5% for 238U capture and 238U inelastic. Results on 239Pu fission cross sections are included in posterior uncertainties. The increase trends on 239Pu capture cross-section is of around 3% in the [2 keV-100 keV] energy range. For 240Pu capture cross section, the increase is of around 4% in the [3 keV-100 keV] energy range and goes in the same direction as a recent evaluation.


2020 ◽  
Vol 239 ◽  
pp. 17021
Author(s):  
Jie Ren ◽  
Xichao Ruan ◽  
Jie Bao ◽  
Guangyuan Luan ◽  
Hanxiong Huang ◽  
...  

Radiative neutron capture cross sections are very important in the field of basic physics research and nuclear device R&D. The Back-n white neutron beam line of China Spallation Neutron Source (CSNS) is the first spallation neutron beam line in China. On the purpose for radiative neutron capture cross section measurement, a C6D6 detector system was built in the Back-n experimental station. The pulse height weighting technique (PHWT) was used to make the system’s detective efficiency independent of the cascade path and the energy of cascade gamma rays. The neutron energy spectrum was measured for the energy between 1eV and 80keV with a 6Li loaded ZnS scintillation detector. Besides, a testing experiment with 197Au and 169Tm samples was carried out to examine this system. According to the preliminary results, this C6D6 detector system can be used to perform neutron capture cross section measurement.


1969 ◽  
Vol 24 (9) ◽  
pp. 1306-1310 ◽  
Author(s):  
K.W. Böer

Abstract With chopped high intensity optical excitation a modulation of the optical absorption in a wide wavelength-range in CdS was observed. This light induced modulation of absorption is attributed to a redistribution of carriers over levels in the band gap following the chopping frequency. With this method the energy spectrum of certain traps and recombination centers can be determined and their frequency factor and capture cross section obtained. This method permits also the analysis of fast recombination centers.


Author(s):  
Yu Kodama ◽  
Tatsuya Katabuchi ◽  
Gerard Rovira ◽  
Atsushi Kimura ◽  
Shoji Nakamura ◽  
...  