Force Transfer Mechanism in Embedded Steel Column Bases

Author(s):  
Young Ho Kim ◽  
Seung Sik Lee ◽  
Jae Ho Jung ◽  
Soon Jong Yoon
2006 ◽  
Vol 326-328 ◽  
pp. 1805-1810 ◽  
Author(s):  
Young Ho Kim ◽  
Seung Sik Lee ◽  
Jae Ho Jung ◽  
Soon Jong Yoon

This paper presents the results of an investigation on the force transfer mechanism in an embedded column base of a composite structure. In the experimental program, eighteen push-out specimens were tested. The factors influencing the mechanism of force transfer were the amount of confining reinforcement, compressive strength of concrete, and diameter of stud connectors. The results of experiment indicated that force transfer could be characterized into two stages, and the factors governing each stage were identified. The first stage was governed by the bond strength between the steel column base and the concrete. The second stage begun after chemical debonding and was governed by the shear strength of stud connectors as well as the frictional strength between the steel and the concrete. Based on the experimental results, the equations to estimate the bond strength, the friction strength, and the shear strength of stud connectors were proposed. The load carrying capacity of an embedded steel column base could be predicted by taking the sum of the shear strength of stud connectors and the friction strength. The predicted load carrying capacity was found to agree well with the experimental results over various range of concrete stress.


2019 ◽  
Vol 2019 ◽  
pp. 1-12 ◽  
Author(s):  
Yufen Zhang ◽  
Dongfang Zhang ◽  
Krushar Demoha

This paper firstly studied the internal force transfer mechanism of vertical stiffener joints in concrete-filled double steel tubular (CFDST) frame structures on the basis of finite element modeling (FEM). Analytical models of shear force and bending moment were established through the appropriate material constitutive equations and equilibrium theory. Then, the proposed models were used to predict and evaluate the shear and bending resistance of the vertical stiffener joint. Six joint specimens were tested to verify the rationality of the theoretical models, and the design suggestions for construction were subsequently discussed. The analysis indicated that the vertical stiffener together with the anchorage web played a dominated role in the internal force transfer mechanism. The computed bending resistance obtained by the tension model agreed well with the measured experimental data, and the shear resistance in the panel zone was sufficient to guarantee the ductile failure in the test. The vertical stiffener determined the plastic hinge so as to ensure the strong connection between the CFDST column and the steel beam. The ribbed anchorage web was an effective way of increasing the shear and bending resistance.


2020 ◽  
Vol 2020 ◽  
pp. 1-12
Author(s):  
Jing Li ◽  
Ya-Fei Jia ◽  
Chen-Xi Miao ◽  
Ming-Xing Xie

Geogrids have been extensively used in subgrade construction for stabilization purposes of unconfined ballast. Based on well-calibrated microparameters, a series of geogrid-reinforced ballast models with different geogrid sizes and particular structures were developed to reproduce the mechanical behavior of the geogrid under pull-out load in this paper. And the rationality of the DEM model is verified by comparing the evolution law pull-out force measured by laboratory tests and numerical simulations under comparable conditions. Moreover, the macro pull-out force and the internal force distribution of the geogrid were analyzed, and the contact force statistical zones of the particle system were divided accurately according to the results. Meanwhile, both the force transfer mechanism in the geogrid-ballast interface and the sectionalized strain of the geogrid were discussed. And results unveil that the pull-out load is transmitted along the longitudinal ribs to the transverse ribs, and nearly 90% of the load is transmitted to the contact network (in statistical zone 1) in front of the first transverse rib, resulting in strong interlocking between the particles occurs in statistical zone 1. And the second transverse rib is the strength dividing line between strong and weak contact forces. Then, additional pull-out tests on the control groups were conducted, and the sectionalized strain of the geogrid and the peak pull-out force, as well as the energy dissipation were systematically analyzed. In addition, the proposed method used in simulation holds much promise for better understanding of the reinforcement mechanism and further optimizing the performance of geogrid-reinforced structures.


Sign in / Sign up

Export Citation Format

Share Document