Advantages of CBCT in Evaluating the Direction of Dental Implant in Immediate Implant: A Case Report

2011 ◽  
Vol 140 ◽  
pp. 91-94
Author(s):  
Yong Bo Gao ◽  
Xi Feng Wu ◽  
Shu Ping Chen ◽  
Li Ming Yang ◽  
Ai Jiang ◽  
...  

Cone beam computed tomography (CBCT) is an exciting development in dental and maxillofacial imaging. This article gives an report for evaluation the direction of dental implant in immediate implant using CBCT

2019 ◽  
Vol 31 (1) ◽  
Author(s):  
Noor Rachmawati ◽  
Ria Noerianingsih Firman ◽  
Deddy Firman ◽  
Sandy P ◽  
Krisna Krisna ◽  
...  

Pendahuluan: Tindakan implan merupakan salah satu upaya untuk mengganti gigi yang hilang. Pemasangan implan yang baik, mampu memberikan kenyamanan dan aspek estetis yang baik. Pemasangan implan yang penuh dengan resiko dan ketidak hati-hatian pada pemasangan berakibat tidak baik bagi pasien. Tujuan dari penulisan laporan kasus ini adalah untuk melaporkan kasus ketidaknyamanan yang disebabkan timbulnya reaksi inflamasi disertai supurasi pada sinus maksilaris paska pemasangan implan, dan juga untuk melihat kemampuan dari Cone Beam Computed Tomography (CBCT) dalam menganalisa hal tersebut. Laporan  kasus: Perempuan berusia 40 tahun, mengeluhkan adanya rasa tidak nyaman berupa bau mulut dan hidung disertai hidung tersumbat dan pusing kepala. Anamnesa diketahui bahwa pasien telah melakukan pemasangan implan 3 bulan sebelumnya. Pemeriksaan intraoral menemukan adanya implan pada regio posterior, tanpa rasa sakit dan tanda peradangan. Manajemen kasus dilakukan dengan meminta pasien melakukan pemeriksaan CBCT, karena dicurigai rasa tidak nyaman, pusing dan bau disebabkan oleh implan yang saat ini telah terpasang. Setelah dilakukan pemeriksaan CBCT ternyata ditemukan sinus aproksimasi pada ujung implan. Ujung implan masuk ke dalam sinus dengan panjang lebih dari 2 mm. Hal ini menyebabkan infeksi pada dinding sinus dan berkumpulnya nanah pada daerah sinus. Hal ini membuktikan bahwa implan menyebabkan infeksi pada sinus sehingga kasus ini terjadi. Pasien kemudian dirujuk ke bagian bedah untuk dilakukan perbaikan pada implan. Simpulan: Inflamasi sinus disertai supurasi pada sinus maksilaris paska pemasangan dapat terjadi, hal ini terjadi kemungkinan karena respon tubuh terhadap implan yang masuk ke rongga sinus. Analisa dapat dilakukan dengan memanfaatkan radiografi CBCT.Kata kunci: Implan, CBCT, infeksi sinus maksilaris. ABSTRACTIntroduction: Dental implant placement is an attempt to replace missing teeth. Installing the right implant can provide comfort and good aesthetic aspects. However, the installation of implants with full risks and caution will hurt the patient; thus proper planning is needed for implant placement. The purpose of this case report was to report cases of discomfort caused by an inflammatory reaction accompanied by suppuration in the maxillary sinus after implant placement and also to see the ability of Cone Beam Computed Tomography (CBCT) in analysing this. Case report: A 40-years-old woman complains of discomfort in the form of bad breath, nasal congestion, and headache. Anamnesa found that the patient had implant placement 3 months earlier. An intraoral examination found an implant in the posterior region, with no signs of pain and inflammation. Case management was performed by asking the patient to do a CBCT examination due to suspected discomfort, dizziness and bad breath caused by implants that are currently installed. After a CBCT examination found a sinus approximation at the tip of the implant. The tip of the implant goes into the sinus with a length of more than 2 mm. This caused an infection of the sinus wall and the gathering of pus in the sinus area. This proves that the implant caused an infection of the sinuses. The patient was then referred to the surgical section for the implant repairment. Conclusion: Sinus inflammation accompanied by suppuration of the maxillary sinus after installation can be occurred likely due to the body’s response towards the implants entering the sinus cavity. Analysis can be performed using CBCT radiography.Keywords: Implant, CBCT, maxillary sinus infection.


2012 ◽  
Vol 2012 ◽  
pp. 1-4 ◽  
Author(s):  
Leila Atash biz Yeganeh ◽  
Mamak Adel ◽  
Reza Vahedi ◽  
Maryam Tofangchiha

Thorough knowledge of root canal morphology is essential for the endodontic therapy. There are rare variations in canal number and configuration in maxillary molars, which could affect treatment outcome. This paper presents the endodontic management of a maxillary first molar with two palatal canals in one root (Vertucci type IV) and a single buccal canal. In this paper cone-beam computed tomography was made to asses this morphology. This paper is intended to reinforce clinician’s awareness of the rare morphology of root canals.


2016 ◽  
Vol 4 (1) ◽  
pp. 1
Author(s):  
Shristhi Sharma ◽  
Ananth Raghav Sharma ◽  
Vivek Kumar Rai ◽  
Ronak Choudhary

Background: Internal anatomy of maxillary first premolars is particularly multifaceted on account of the variation in number of roots and canal configuration. Maxillary first premolars with 3 roots are called as small molar or “radiculous” because of their similar anatomy to the maxillary first molars. The most demanding step in endodontic treatment is identification and proper access to pulp canals of certain teeth with atypical canal configurations. Methods of identification of such premolars can be by various aides.Case Presentation: The present case describes the application of Cone Beam-Computed Tomography in the diagnosis of extra root with extra canal in a three rooted maxillary right first premolar.Conclusions: Proper knowledge of the anatomical variations is a must for an endodontist to make a treatment successful. Utilizing the latest technology along with the traditional concepts can surely rule out the inaccuracy in the treatment involved in such cases.


Sign in / Sign up

Export Citation Format

Share Document