Improved Method Based on Fluid Mechanics Analysis for Buoy Gauge Design and Experimental Research

2012 ◽  
Vol 163 ◽  
pp. 133-137
Author(s):  
Ao Yu Chen ◽  
Xu Dong Pan ◽  
Guang Lin Wang

Traditional method of buoy gauge design is rather complicated, so an advanced method by building and solving fluid mechanics equations is proposed in this paper. The curve of the taper pipe inner surface is calculated, according to different buoy gravity and diameter. In order to examine the effect of this improved method, an experiment is carried out. Results show that linear property of the buoy gauge improved by new method is excellent.

2012 ◽  
Vol 178-181 ◽  
pp. 1250-1253
Author(s):  
Yu Hua Li ◽  
Kai Huang ◽  
Ying Zhen Gao

When we make design of mixture ratio, we always use normal equation method (NEM), but the solution value of that method may doesn’t meet our demand. When we use the new method that proposed in this paper, we can solve the problem. The new method makes an improvement for NEM. By iterative algorithm, the new method uses the gradation data calculated by NEM as initial target value, canceling the relevant aggregate if the result of proportion is negative, and setting the gradation to the boundary value if the target value goes beyond limits. According to the adjusted object value, using NEM again, the new aggregate proportion can be solved. Then the new gradation of mixture will come into being the next target value. Finally, the accurate result will meet our need. The new improved method has good engineering applicability and high accuracy


2021 ◽  
Vol 1037 ◽  
pp. 227-232
Author(s):  
Nikita A. Zemlyanushnov ◽  
Nadezhda Y. Zemlyanushnova

The disadvantage of the known methods of hardening springs is the impossibility of their use when hardening springs of a conical shape or of a shape of a paraboloid of rotation, since they are intended only for cylindrical shape springs and are not suitable for conical shape springs or those of a shape of a paraboloid of rotation specifically because of the difference in the shape of the springs. One of the disadvantages of the known springs hardening mechanisms is the impossibility of hardening the inner surface of the conical compression springs. A new method of hardening springs is proposed, the unmatched advantage of which is the ability to create plastic deformations on the inner and outer surfaces of the spring coils compressed to contact and on the surfaces along the line of contact between the coils. A new advantageous mechanism for hardening springs is proposed, which makes it possible to harden the inner surface of compression springs having a conical shape or a paraboloid shape of rotation, in a compressed state.


2011 ◽  
Vol 418-420 ◽  
pp. 1804-1807
Author(s):  
Li Li ◽  
Zheng Hui Tan ◽  
Jia Wen Liu

Traditional method for measuring liquid level of absorption tower in wet flue gas desulfurization (WFGD) system is introduced in this paper, and it's found that measuring accuracy of the method exists in large deviation. A new method is proposed to measure liquid level of absorption tower for this situation. The local test results show that not only measurement result of new method is more close to the actual liquid level than traditional method, but also using new method can save operation cost and ensure the safety, stability, and economic operation of WFGD system.


2014 ◽  
Vol 602-605 ◽  
pp. 3177-3180
Author(s):  
Wei Ping Cui ◽  
Li Juan Du

In this paper, through comparison and analysis of various wavelet denoising methods, a new threshold function is constructed, and the selection of threshold is improved. Signal denoising simulation is made by the software MATLAB, the results show that the improved method is superior to the traditional method, and obtain a better denoising effect.


Humaniora ◽  
2014 ◽  
Vol 5 (2) ◽  
pp. 1114
Author(s):  
Wishnoebroto Wishnoebroto

Flipping a classroom is not only recording classroom lesson into a video and bringing homework into the classroom. It is a whole new method with a lot better result compared to the traditional method. In western countries such as the US, flipping a classroom is already becoming a new method adopted by many different schools and universities. This paper tries to explore the possibility of flipping a classroom for learning foreign language at BINUS University by comparing it with the recent practices and findings in the western countries. After the analysis it can be concluded that this method can be applied at BINUS University but on several conditions such as the improvement of infrastructures, and the teacher’s awareness and understanding to optimize their understanding about flipped learning. 


1986 ◽  
Vol 53 (3) ◽  
pp. 579-586 ◽  
Author(s):  
T. Kundu

In this paper, the transient response of an interface crack, in a two layered plate subjected to an antiplane stress field, is analytically computed. The problem is formulated in terms of semi-infinite integrals following the technique developed by Neerhoff (1979). It has been shown that the major steps of Neerhoff’s technique, which was originally developed for layered half-spaces, can also be applied to layered plate problems. An improved method for manipulation of semi-infinite singular integrals is also presented here. Finally, the new method is coded in FORTRAN program and numerical results for a sample problem are presented.


2020 ◽  
Vol 64 (3) ◽  
Author(s):  
Ling Li ◽  
Yongqiong Lin ◽  
Fang Yang ◽  
Tongdan Zou ◽  
Jialiang Yang ◽  
...  

Immunohistochemistry using mouse retinal cryosections is a routine assay used in vision research. However, retinal tissues are fragile, and it is difficult to obtain an ideal retinal cryosection. Here, we developed a modified method for preparing retinal cryosection. Super Glue was applied on the surface of the sclera before the cornea and the lens are removed from either the unfixed or PFA-fixed mouse eyeballs. The new methods largely prevented retinal detachment in mouse retinal cryosections. Immunostaining of retinal cryosections derived from PFA-fixed mouse eyes using rod and cone markers yielded high-quality immunofluorescent images. Immunolabeling of retinal cryosections obtained from unfixed mouse eyes using a cilium-specific marker had improved orientations of photoreceptor connecting cilia. This new method substantially improves the morphology and immunostaining results of fixed and unfixed mouse eyes.


2013 ◽  
Vol 448-453 ◽  
pp. 2137-2142
Author(s):  
Xiao Jian Ye ◽  
Zhen Gang Duan ◽  
Zhuo Shen ◽  
Xiao Qin Lian ◽  
Xiao Li Zhang

This paper elaborates a method to realize the single phase full bridge inverter digital controller based on DSP TMS320F28027 and gives the design scheme of both its hardware and its software. In accordance with SPWM duty ratio parameter calculated with DSP algorithm, utilizing the EPWM module on DSP, it finally attains the inverting control from direct current signal to sine wave signal. Compared with traditional method, this new method improves the output waveform effectively and shows stable performance.


2014 ◽  
Vol 644-650 ◽  
pp. 1429-1432
Author(s):  
Tian Yu Sun ◽  
Yan Bo Liu ◽  
Tian Su Wei ◽  
Fu Cheng Yin

There is not any calibration specification or verification regulation for the milliampere-second meter, a very important instrument for preventive maintenance and calibrating the X-ray machine [1][2], is used to measure the value of the product of tube current and exposure time. To solve the problem that the traditional method can not offer the same standard value in different times, this paper presents a method for calibrating the milliampere-second meter by using a signal generator and a digital meter. It shows that the new method has good repeatability and stability.


Sign in / Sign up

Export Citation Format

Share Document